{"id":"https://openalex.org/W4414144807","doi":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","title":"Automation and accuracy improvement of field calibration for tipping-bucket rain gauges using laser sensors and roller pump","display_name":"Automation and accuracy improvement of field calibration for tipping-bucket rain gauges using laser sensors and roller pump","publication_year":2025,"publication_date":"2025-09-12","ids":{"openalex":"https://openalex.org/W4414144807","doi":"https://doi.org/10.1016/j.flowmeasinst.2025.103063"},"language":"en","primary_location":{"id":"doi:10.1016/j.flowmeasinst.2025.103063","doi":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","pdf_url":null,"source":{"id":"https://openalex.org/S46058507","display_name":"Flow Measurement and Instrumentation","issn_l":"0955-5986","issn":["0955-5986","1873-6998"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Flow Measurement and Instrumentation","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5126388379","display_name":"Bokjin Jang","orcid":"https://orcid.org/0009-0008-4538-3718","observed_orcids":["https://orcid.org/0009-0008-4538-3718"]},"institutions":[{"id":"https://openalex.org/I4405262078","display_name":"Korea Institute of Hydrological Survey","ror":"https://ror.org/017z1f632","country_code":"KR","type":"government","lineage":["https://openalex.org/I4405262078"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Bokjin Jang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101471642","display_name":"Geon-Woo Kim","orcid":"https://orcid.org/0000-0002-4504-765X","observed_orcids":["https://orcid.org/0000-0002-4504-765X"]},"institutions":[{"id":"https://openalex.org/I4405262078","display_name":"Korea Institute of Hydrological Survey","ror":"https://ror.org/017z1f632","country_code":"KR","type":"government","lineage":["https://openalex.org/I4405262078"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"GeonWoo Kim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100426016","display_name":"Sung-Hyun Kim","orcid":"https://orcid.org/0000-0001-5304-7847","observed_orcids":["https://orcid.org/0000-0001-5304-7847"]},"institutions":[{"id":"https://openalex.org/I4405262078","display_name":"Korea Institute of Hydrological Survey","ror":"https://ror.org/017z1f632","country_code":"KR","type":"government","lineage":["https://openalex.org/I4405262078"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"SeHoon Kim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5115589031","display_name":"SungHyun Kim","orcid":"https://orcid.org/0000-0003-3898-0393","observed_orcids":["https://orcid.org/0000-0003-3898-0393"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"SungHyun Kim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5126388379"],"corresponding_institution_ids":["https://openalex.org/I4405262078"],"apc_list":{"value":3080,"currency":"USD","value_usd":3080},"apc_paid":{"value":3080,"currency":"USD","value_usd":3080},"fwci":0.311,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.3675406,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":"107","issue":null,"first_page":"103063","last_page":"103063"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11234","display_name":"Precipitation Measurement and Analysis","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11234","display_name":"Precipitation Measurement and Analysis","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.0015999999595806003,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.0012000000569969416,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/tipping-bucket-rain-gauge","display_name":"tipping bucket rain gauge","score":0.9679999947547913},{"id":"https://openalex.org/keywords/rain-gauge-calibration","display_name":"rain gauge calibration","score":0.8040000200271606},{"id":"https://openalex.org/keywords/laser-sensor","display_name":"laser sensor","score":0.824999988079071},{"id":"https://openalex.org/keywords/roller-pump","display_name":"roller pump","score":0.9929999709129333},{"id":"https://openalex.org/keywords/expanded-uncertainty","display_name":"expanded uncertainty","score":0.7549999952316284}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.782800018787384},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.6401000022888184},{"id":"https://openalex.org/C122383733","wikidata":"https://www.wikidata.org/wiki/Q865920","display_name":"Approximation error","level":2,"score":0.6306999921798706},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5594000220298767},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5547999739646912},{"id":"https://openalex.org/C62649853","wikidata":"https://www.wikidata.org/wiki/Q199687","display_name":"Remote sensing","level":1,"score":0.5098999738693237},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46399998664855957},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.4474000036716461},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.44290000200271606},{"id":"https://openalex.org/C93038891","wikidata":"https://www.wikidata.org/wiki/Q1061524","display_name":"Intensity (physics)","level":2,"score":0.3935000002384186},{"id":"https://openalex.org/C168498295","wikidata":"https://www.wikidata.org/wiki/Q641296","display_name":"Total station","level":2,"score":0.3790999948978424},{"id":"https://openalex.org/C202799725","wikidata":"https://www.wikidata.org/wiki/Q272035","display_name":"Accuracy and precision","level":2,"score":0.3781999945640564},{"id":"https://openalex.org/C3019060180","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automated method","level":2,"score":0.37470000982284546},{"id":"https://openalex.org/C62646347","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measuring instrument","level":2,"score":0.33250001072883606},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3260999917984009},{"id":"https://openalex.org/C2779565104","wikidata":"https://www.wikidata.org/wiki/Q5447138","display_name":"Field trial","level":2,"score":0.3248000144958496},{"id":"https://openalex.org/C520434653","wikidata":"https://www.wikidata.org/wiki/Q38867","display_name":"Laser","level":2,"score":0.2994000017642975},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.2791000008583069},{"id":"https://openalex.org/C51399673","wikidata":"https://www.wikidata.org/wiki/Q504027","display_name":"Lidar","level":2,"score":0.2590999901294708}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1016/j.flowmeasinst.2025.103063","doi":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","pdf_url":null,"source":{"id":"https://openalex.org/S46058507","display_name":"Flow Measurement and Instrumentation","issn_l":"0955-5986","issn":["0955-5986","1873-6998"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Flow Measurement and Instrumentation","raw_type":"journal-article"},{"id":"doi:10.2139/ssrn.5253237","doi":"https://doi.org/10.2139/ssrn.5253237","is_oa":true,"landing_page_url":"https://doi.org/10.2139/ssrn.5253237","pdf_url":null,"source":{"id":"https://openalex.org/S4210172589","display_name":"SSRN Electronic Journal","issn_l":"1556-5068","issn":["1556-5068"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1318003438","host_organization_name":"RELX Group (Netherlands)","host_organization_lineage":["https://openalex.org/I1318003438"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"}],"best_oa_location":{"id":"doi:10.1016/j.flowmeasinst.2025.103063","doi":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.flowmeasinst.2025.103063","pdf_url":null,"source":{"id":"https://openalex.org/S46058507","display_name":"Flow Measurement and Instrumentation","issn_l":"0955-5986","issn":["0955-5986","1873-6998"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Flow Measurement and Instrumentation","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F541516609","display_name":"Korea Institute","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1964578041","https://openalex.org/W1981480030","https://openalex.org/W2024688242","https://openalex.org/W2038107219","https://openalex.org/W2055388886","https://openalex.org/W2056825791","https://openalex.org/W2070536168","https://openalex.org/W2070957843","https://openalex.org/W2159957837","https://openalex.org/W2160804315","https://openalex.org/W2180492749","https://openalex.org/W2191797599","https://openalex.org/W2343120927","https://openalex.org/W2383504267","https://openalex.org/W2461783222","https://openalex.org/W2580822948","https://openalex.org/W2622098714","https://openalex.org/W2954601359","https://openalex.org/W2994868666","https://openalex.org/W2996748619","https://openalex.org/W3196078312","https://openalex.org/W4379798522","https://openalex.org/W4403160708"],"related_works":["https://openalex.org/W4410337908","https://openalex.org/W7222353868","https://openalex.org/W7130504218","https://openalex.org/W2055388886","https://openalex.org/W4403160708","https://openalex.org/W247752212","https://openalex.org/W2156286715","https://openalex.org/W3110279970","https://openalex.org/W2357605453","https://openalex.org/W3203542893"],"abstract_inverted_index":{"This":[0],"study":[1],"developed":[2],"a":[3,22,42],"portable":[4],"automated":[5,71,115,135,174],"calibration":[6,175],"device":[7,25,72,95,116,136],"(PRC-20AP)":[8],"for":[9,66,181,196],"tipping-bucket":[10],"rain":[11],"gauges":[12],"(TBRGs)":[13],"and":[14,38,59,81,128,140,158,185],"quantitatively":[15],"evaluated":[16],"its":[17],"performance":[18],"through":[19],"comparison":[20],"with":[21,41],"conventional":[23],"manual":[24,75,94,194],"(burette).":[26],"Experiments":[27],"were":[28],"conducted":[29],"under":[30,83],"rainfall":[31,45,68,111,131,188],"intensities":[32,89],"of":[33,46,79,187],"10,":[34],"20,":[35],"30,":[36],"50,":[37],"100":[39,149],"mm/h,":[40,92,150],"target":[43],"total":[44,67],"20":[47,91],"mm.":[48],"Each":[49],"condition":[50],"was":[51,101],"tested":[52],"15":[53],"times":[54],"to":[55,103,108],"calculate":[56],"relative":[57,98,152],"errors":[58],"expanded":[60,120,160],"uncertainties.":[61],"The":[62],"results":[63],"showed":[64,137],"that,":[65],"measurements,":[69,133,189],"the":[70,74,93,114,134,144,151,159,173,183],"outperformed":[73],"method":[76],"in":[77],"terms":[78],"accuracy":[80,139],"uncertainty":[82,142,161],"low-intensity":[84],"conditions":[85],"(\u226420":[86],"mm/h).":[87],"At":[88,148],"above":[90],"exhibited":[96],"smaller":[97],"errors,":[99],"which":[100],"attributed":[102],"structural":[104],"factors":[105],"that":[106,172],"led":[107],"reduced":[109],"actual":[110],"intensity.":[112],"However,":[113],"consistently":[117],"demonstrated":[118],"lower":[119,141],"uncertainties":[121],"across":[122,143],"all":[123],"conditions,":[124],"indicating":[125],"superior":[126],"precision":[127,184],"repeatability.":[129],"For":[130],"intensity":[132],"better":[138],"entire":[145],"test":[146],"range.":[147],"error":[153],"improved":[154],"by":[155,163],"5.78":[156],"%,":[157],"decreased":[162],"0.17":[164],"mm/h":[165],"(approximately":[166],"65.9":[167],"%).":[168],"These":[169],"findings":[170],"confirm":[171],"system":[176],"is":[177],"an":[178],"effective":[179],"alternative":[180],"enhancing":[182],"reliability":[186],"offering":[190],"practical":[191],"advantages":[192],"over":[193],"methods":[195],"field":[197],"applications.":[198]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-11-12T12:28:57.059296","created_date":"2025-10-10T00:00:00"}