{"id":"https://openalex.org/W4413079522","doi":"https://doi.org/10.56975/tijer.v8i12.159059","title":"Back to Back Testing of Medium Voltage (MV) Drives","display_name":"Back to Back Testing of Medium Voltage (MV) Drives","publication_year":2021,"publication_date":"2021-01-01","ids":{"openalex":"https://openalex.org/W4413079522","doi":"https://doi.org/10.56975/tijer.v8i12.159059"},"language":"en","primary_location":{"id":"doi:10.56975/tijer.v8i12.159059","doi":"https://doi.org/10.56975/tijer.v8i12.159059","is_oa":true,"landing_page_url":"https://doi.org/10.56975/tijer.v8i12.159059","pdf_url":"https://tijer.org/tijer/papers/TIJER2112003.pdf","source":{"id":"https://openalex.org/S4387283545","display_name":"Technix International Journal for Engineering Research","issn_l":"2349-9249","issn":["2349-9249"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Technix International Journal for Engineering Research","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://tijer.org/tijer/papers/TIJER2112003.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Naveen Garg","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Naveen Garg","raw_affiliation_strings":["GE Power Conversion"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"GE Power Conversion","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":7,"citation_normalized_percentile":{"value":0.18826318,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"8","issue":"12","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.6851000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.6851000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.23409999907016754,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.020099999383091927,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/back-to-back-testing","display_name":"back-to-back testing","score":0.9919999837875366},{"id":"https://openalex.org/keywords/medium-voltage-drives","display_name":"medium voltage drives","score":0.996999979019165},{"id":"https://openalex.org/keywords/pwm-voltage-source-inverter","display_name":"PWM voltage source inverter","score":0.9929999709129333},{"id":"https://openalex.org/keywords/neutral-point-clamped-inverter","display_name":"neutral point clamped inverter","score":0.902999997138977},{"id":"https://openalex.org/keywords/fault-protection","display_name":"fault protection","score":0.8199999928474426},{"id":"https://openalex.org/keywords/grounding","display_name":"grounding","score":0.5329999923706055},{"id":"https://openalex.org/keywords/thermal-analysis","display_name":"thermal analysis","score":0.7749999761581421}],"concepts":[{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4530872106552124},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33456099033355713},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.29484906792640686},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19993150234222412}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.56975/tijer.v8i12.159059","doi":"https://doi.org/10.56975/tijer.v8i12.159059","is_oa":true,"landing_page_url":"https://doi.org/10.56975/tijer.v8i12.159059","pdf_url":"https://tijer.org/tijer/papers/TIJER2112003.pdf","source":{"id":"https://openalex.org/S4387283545","display_name":"Technix International Journal for Engineering Research","issn_l":"2349-9249","issn":["2349-9249"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Technix International Journal for Engineering Research","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.56975/tijer.v8i12.159059","doi":"https://doi.org/10.56975/tijer.v8i12.159059","is_oa":true,"landing_page_url":"https://doi.org/10.56975/tijer.v8i12.159059","pdf_url":"https://tijer.org/tijer/papers/TIJER2112003.pdf","source":{"id":"https://openalex.org/S4387283545","display_name":"Technix International Journal for Engineering Research","issn_l":"2349-9249","issn":["2349-9249"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Technix International Journal for Engineering Research","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.8970999717712402},{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8485000133514404}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4413079522.pdf","grobid_xml":"https://content.openalex.org/works/W4413079522.grobid-xml"},"referenced_works_count":27,"referenced_works":["https://openalex.org/W2000322318","https://openalex.org/W2011645538","https://openalex.org/W2015936172","https://openalex.org/W2053429032","https://openalex.org/W2082104506","https://openalex.org/W2116444921","https://openalex.org/W2118980069","https://openalex.org/W2124302608","https://openalex.org/W2149948433","https://openalex.org/W2547305990","https://openalex.org/W2554545329","https://openalex.org/W2605820745","https://openalex.org/W2775948282","https://openalex.org/W2792083861","https://openalex.org/W2799006754","https://openalex.org/W2883155917","https://openalex.org/W2884474037","https://openalex.org/W2901081742","https://openalex.org/W2905547138","https://openalex.org/W2907413583","https://openalex.org/W2947263668","https://openalex.org/W2980055862","https://openalex.org/W3009486001","https://openalex.org/W3015984769","https://openalex.org/W3017807770","https://openalex.org/W3022222437","https://openalex.org/W3095687013"],"related_works":["https://openalex.org/W1961635809","https://openalex.org/W7130714735","https://openalex.org/W2527969606","https://openalex.org/W4391428985","https://openalex.org/W1987760667","https://openalex.org/W7098110335","https://openalex.org/W4413145452","https://openalex.org/W2376559652","https://openalex.org/W2041175391","https://openalex.org/W2907413583"],"abstract_inverted_index":{"Back-to-back":[0],"(B2B)":[1],"testing":[2,155],"is":[3,118],"a":[4,31,46,157],"reliable":[5],"and":[6,13,71,82,105,126,130,133,143,151],"energy-efficient":[7],"method":[8],"for":[9,77,90,160],"verifying":[10],"the":[11,93,148],"safe":[12],"accurate":[14],"performance":[15,125],"of":[16,114,153],"medium":[17],"voltage":[18],"(MV)":[19],"drives":[20,41],"under":[21],"full-load":[22],"conditions":[23],"without":[24],"external":[25],"mechanical":[26],"loads.":[27],"This":[28],"paper":[29],"presents":[30],"comprehensive":[32],"investigation":[33],"into":[34],"B2B":[35,94,154],"testing,":[36,124],"where":[37],"two":[38],"regenerative":[39],"MV":[40,61,161],"are":[42,88,110],"interconnected":[43],"to":[44,146],"form":[45],"closed-loop":[47],"energy":[48],"recirculation":[49],"system,":[50],"closely":[51],"replicating":[52],"operational":[53],"environments":[54],"while":[55],"reducing":[56],"grid":[57],"power":[58],"draw.":[59],"Several":[60],"drive":[62,162],"topologies,":[63],"including":[64,120],"PWM":[65],"Current":[66],"Source":[67,73],"Inverters":[68,74],"(PWM":[69,75],"CSI)":[70],"Voltage":[72],"VSI)":[76],"Neutral":[78,83],"Point":[79,84],"Clamped":[80],"(NPC)":[81],"Piloted":[85],"(NPP)":[86],"inverters,":[87],"evaluated":[89],"compatibility":[91],"within":[92],"setup.":[95],"Key":[96],"safety":[97],"aspects":[98],"such":[99],"as":[100,156],"fault":[101,135],"protection,":[102],"isolation,":[103],"grounding,":[104],"compliance":[106],"with":[107],"industrial":[108,144],"standards":[109],"addressed.":[111],"A":[112],"range":[113],"design":[115],"validation":[116],"techniques":[117],"reviewed,":[119],"hardware":[121],"validation,":[122],"software":[123],"thermal":[127],"analysis,":[128],"noise":[129],"losses":[131],"measurement,":[132],"real-time":[134],"injection.":[136],"The":[137],"study":[138],"also":[139],"explores":[140],"recent":[141],"literature":[142],"applications":[145],"highlight":[147],"scalability,":[149],"efficiency,":[150],"practicality":[152],"modern":[158],"solution":[159],"verification.":[163]},"counts_by_year":[{"year":2026,"cited_by_count":7}],"updated_date":"2026-11-08T12:12:28.789561","created_date":"2025-08-11T00:00:00"}
