{"id":"https://openalex.org/W4412377777","doi":"https://doi.org/10.6110/kjacr.2025.37.7.351","title":"Heat Exchange Efficiency and Recovery Efficiency Evaluation Method of Bidirectional Heat Recovery Ventilation System","display_name":"Heat Exchange Efficiency and Recovery Efficiency Evaluation Method of Bidirectional Heat Recovery Ventilation System","publication_year":2025,"publication_date":"2025-07-14","ids":{"openalex":"https://openalex.org/W4412377777","doi":"https://doi.org/10.6110/kjacr.2025.37.7.351"},"language":"en","primary_location":{"id":"doi:10.6110/kjacr.2025.37.7.351","doi":"https://doi.org/10.6110/kjacr.2025.37.7.351","is_oa":false,"landing_page_url":"https://doi.org/10.6110/kjacr.2025.37.7.351","pdf_url":null,"source":{"id":"https://openalex.org/S4306495615","display_name":"\uc124\ube44\uacf5\ud559\ub17c\ubb38\uc9d1","issn_l":"1229-6422","issn":["1229-6422","2465-7611"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Korean Journal of Air-Conditioning and Refrigeration Engineering","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077263282","display_name":"Sowoo Park","orcid":"https://orcid.org/0000-0001-9696-1065","observed_orcids":["https://orcid.org/0000-0001-9696-1065"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sowoo Park","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5017775980","display_name":"Doosam Song","orcid":"https://orcid.org/0000-0002-9177-2166","observed_orcids":["https://orcid.org/0000-0002-9177-2166"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Doosam Song","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.12540023,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"37","issue":"7","first_page":"351","last_page":"361"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.5454000234603882,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.5454000234603882,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.1907999962568283,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.15189999341964722,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/heat-transfer-efficiency","display_name":"heat transfer efficiency","score":0.9129999876022339},{"id":"https://openalex.org/keywords/heat-recovery-efficiency","display_name":"heat recovery efficiency","score":0.9869999885559082}],"concepts":[{"id":"https://openalex.org/C127145964","wikidata":"https://www.wikidata.org/wiki/Q2142051","display_name":"Heat recovery ventilation","level":3,"score":0.6618733406066895},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.6067644953727722},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.5181995034217834},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.479356586933136},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15800145268440247},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.14440008997917175}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.6110/kjacr.2025.37.7.351","doi":"https://doi.org/10.6110/kjacr.2025.37.7.351","is_oa":false,"landing_page_url":"https://doi.org/10.6110/kjacr.2025.37.7.351","pdf_url":null,"source":{"id":"https://openalex.org/S4306495615","display_name":"\uc124\ube44\uacf5\ud559\ub17c\ubb38\uc9d1","issn_l":"1229-6422","issn":["1229-6422","2465-7611"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Korean Journal of Air-Conditioning and Refrigeration Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8485000133514404}],"sustainable_development_goals_aurora":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8899999856948853}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2777543574","https://openalex.org/W2368921210","https://openalex.org/W2361751012","https://openalex.org/W1986081402","https://openalex.org/W4386349008","https://openalex.org/W2383131030","https://openalex.org/W2914869204","https://openalex.org/W4362732940","https://openalex.org/W2317531725","https://openalex.org/W2016136711"],"abstract_inverted_index":{"This":[0],"study":[1],"proposes":[2],"a":[3,12,20,44,66,88,152,163,172],"new":[4],"evaluation":[5,160],"method":[6,25,72],"for":[7,53,174],"assessing":[8],"the":[9,27,97,101,106,121,129,134],"performance":[10,99],"of":[11,100,133,167,179],"bidirectional":[13],"heat":[14,33,68,89,109,115,122,130],"recovery":[15,90,131],"ventilation":[16,181],"system":[17,47],"equipped":[18],"with":[19],"thermal":[21,98],"storage":[22,102,135],"element.":[23],"The":[24,36,157],"reflects":[26],"system\u2019s":[28],"time-dependent":[29],"operating":[30],"characteristics":[31],"and":[32,48,59,78,111,128,146,170,177],"exchange":[34,69,123],"behavior.":[35],"existing":[37],"KS":[38],"B":[39],"6879":[40],"standard,":[41],"based":[42,81],"on":[43,82],"steady-state":[45],"dual-duct":[46],"temperature-based":[49],"calculation,":[50],"is":[51,73,93],"unsuitable":[52],"single-duct,":[54],"alternating":[55],"systems":[56,169],"where":[57],"supply":[58],"exhaust":[60],"occur":[61],"sequentially.":[62],"To":[63],"address":[64],"this,":[65],"cycle-based":[67],"efficiency":[70,91,124,132],"calculation":[71],"introduced,":[74],"using":[75],"time-varying":[76],"airflow":[77,144],"temperature":[79],"data":[80],"accumulated":[83],"outdoor":[84],"air":[85],"load.":[86],"Additionally,":[87],"metric":[92],"defined":[94],"to":[95,151],"evaluate":[96],"element":[103,136],"by":[104],"quantifying":[105],"net":[107],"sensible":[108],"stored":[110],"released,":[112],"excluding":[113],"duct":[114],"exchange.":[116],"Experimental":[117],"results":[118],"showed":[119],"that":[120,143],"was":[125,137,140],"approximately":[126],"50%,":[127],"62.72%.":[138],"It":[139],"also":[141],"observed":[142],"delay":[145],"extended":[147],"cycle":[148],"intervals":[149],"led":[150],"gradual":[153],"decline":[154],"in":[155],"performance.":[156],"proposed":[158],"dual-index":[159],"framework":[161],"offers":[162],"more":[164],"accurate":[165],"assessment":[166],"such":[168],"provides":[171],"foundation":[173],"design,":[175],"comparison,":[176],"optimization":[178],"various":[180],"solutions.":[182]},"counts_by_year":[],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2025-10-10T00:00:00"}