{"id":"https://openalex.org/W4409499596","doi":"https://doi.org/10.5006/c2025-00274","title":"Measuring Atmospheric Corrosion is Hard \u2013 AC vs DC Methods","display_name":"Measuring Atmospheric Corrosion is Hard \u2013 AC vs DC Methods","publication_year":2025,"publication_date":"2025-04-06","ids":{"openalex":"https://openalex.org/W4409499596","doi":"https://doi.org/10.5006/c2025-00274"},"language":"en","primary_location":{"id":"doi:10.5006/c2025-00274","doi":"https://doi.org/10.5006/c2025-00274","is_oa":false,"landing_page_url":"https://doi.org/10.5006/c2025-00274","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"CONFERENCE 2025","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113617402","display_name":"Thomas Hayden","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Thomas Hayden","raw_affiliation_strings":["Engineering Director, Inc. , P.O. Box 2328 , TAG city ENDTAG Crystal Lake &lt;/city&gt; , TAG state ENDTAG IL &lt;/state&gt; , TAG postal-code ENDTAG 60039 &lt;/postal-code&gt; ,"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Engineering Director, Inc. , P.O. Box 2328 , TAG city ENDTAG Crystal Lake &lt;/city&gt; , TAG state ENDTAG IL &lt;/state&gt; , TAG postal-code ENDTAG 60039 &lt;/postal-code&gt; ,","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057323829","display_name":"Haralampos Tsaprailis","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405271185","display_name":"Enbridge Inc. (Canada)","ror":"https://ror.org/020z2z230","country_code":"CA","type":"company","lineage":["https://openalex.org/I4405271185"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Haralampos Tsaprailis","raw_affiliation_strings":["Enbridge Employee Services Canada Inc. , 10175-101 Street Edmonton , TAG city ENDTAG Alberta &lt;/city&gt; , TAG postal-code ENDTAG T5J 0H3 &lt;/postal-code&gt; ,"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Enbridge Employee Services Canada Inc. , 10175-101 Street Edmonton , TAG city ENDTAG Alberta &lt;/city&gt; , TAG postal-code ENDTAG T5J 0H3 &lt;/postal-code&gt; ,","institution_ids":["https://openalex.org/I4405271185"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100341542","display_name":"Joesphan Lu","orcid":"https://orcid.org/0000-0001-9612-3539","observed_orcids":["https://orcid.org/0000-0001-9612-3539"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Joesphan Lu","raw_affiliation_strings":["AtmosphericIQ LLC , P.O. Box 2328 , TAG city ENDTAG Crystal Lake &lt;/city&gt; , TAG state ENDTAG IL &lt;/state&gt; , TAG postal-code ENDTAG 60039 &lt;/postal-code&gt; ,"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"AtmosphericIQ LLC , P.O. Box 2328 , TAG city ENDTAG Crystal Lake &lt;/city&gt; , TAG state ENDTAG IL &lt;/state&gt; , TAG postal-code ENDTAG 60039 &lt;/postal-code&gt; ,","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5117174688","display_name":"Nicole Mazzella","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Nicole Mazzella","raw_affiliation_strings":["AtmosphericIQ LLC , P.O. Box 2328 , TAG city ENDTAG Crystal Lake &lt;/city&gt; , TAG state ENDTAG IL &lt;/state&gt; , TAG postal-code ENDTAG 60039 &lt;/postal-code&gt; ,"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"AtmosphericIQ LLC , P.O. Box 2328 , TAG city ENDTAG Crystal Lake &lt;/city&gt; , TAG state ENDTAG IL &lt;/state&gt; , TAG postal-code ENDTAG 60039 &lt;/postal-code&gt; ,","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.10874285,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"14"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10310","display_name":"Corrosion Behavior and Inhibition","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10310","display_name":"Corrosion Behavior and Inhibition","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13891","display_name":"Engineering Diagnostics and Reliability","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/atmospheric-corrosion","display_name":"atmospheric corrosion","score":0.9179999828338623},{"id":"https://openalex.org/keywords/corrosion-rate-measurement","display_name":"corrosion rate measurement","score":0.8999999761581421},{"id":"https://openalex.org/keywords/ac-impedance","display_name":"AC impedance","score":0.652999997138977},{"id":"https://openalex.org/keywords/dc-resistance","display_name":"DC resistance","score":0.8949999809265137},{"id":"https://openalex.org/keywords/electrochemical-impedance-spectroscopy","display_name":"electrochemical impedance spectroscopy","score":0.9430000185966492},{"id":"https://openalex.org/keywords/cyclic-voltammetry","display_name":"cyclic voltammetry","score":1.0},{"id":"https://openalex.org/keywords/wheatstone-bridge","display_name":"Wheatstone bridge","score":0.9430000185966492},{"id":"https://openalex.org/keywords/metal-corrosion","display_name":"metal corrosion","score":0.5490000247955322},{"id":"https://openalex.org/keywords/electrode-design","display_name":"electrode design","score":0.6069999933242798}],"concepts":[{"id":"https://openalex.org/C20625102","wikidata":"https://www.wikidata.org/wiki/Q137056","display_name":"Corrosion","level":2,"score":0.5900905728340149},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4745643734931946},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4318722188472748},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.36087191104888916},{"id":"https://openalex.org/C191897082","wikidata":"https://www.wikidata.org/wiki/Q11467","display_name":"Metallurgy","level":1,"score":0.24525323510169983}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.5006/c2025-00274","doi":"https://doi.org/10.5006/c2025-00274","is_oa":false,"landing_page_url":"https://doi.org/10.5006/c2025-00274","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"CONFERENCE 2025","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1489619951","https://openalex.org/W1910335558","https://openalex.org/W1968805894","https://openalex.org/W2017561156","https://openalex.org/W2033761698","https://openalex.org/W2305956023","https://openalex.org/W4230985827","https://openalex.org/W4409485720","https://openalex.org/W4409500894","https://openalex.org/W4409501251"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2349891746","https://openalex.org/W2884282816","https://openalex.org/W2394115446","https://openalex.org/W1502342084","https://openalex.org/W4404995717","https://openalex.org/W2016187641","https://openalex.org/W4404725684"],"abstract_inverted_index":{"Abstract":[0],"The":[1,97,114],"aspiration":[2],"of":[3,13,19],"atmospheric":[4],"corrosion":[5,17,81],"monitoring":[6],"is":[7,82],"to":[8,129,158],"develop":[9],"an":[10],"electrode":[11,149],"capable":[12],"accurately":[14],"measuring":[15,80],"the":[16,37,91,95,119,126,144],"rate":[18],"metal":[20],"in":[21,29,90,94,111,125,137,148],"a":[22,75,152],"given":[23],"environment,":[24],"ideally":[25],"by":[26,35],"detecting":[27],"changes":[28,124],"electromagnetic":[30],"properties.":[31],"This":[32,84],"study":[33,145],"begins":[34],"reviewing":[36],"available":[38],"techniques,":[39],"including":[40],"alternating":[41],"current":[42,47],"(AC)":[43],"impedance":[44,52,108,159],"measurements,":[45,50,109],"direct":[46],"(DC)":[48],"resistance":[49],"electrochemical":[51],"spectroscopy":[53],"(EIS),":[54],"and":[55,66,93,156],"cyclic":[56,162],"voltammetry":[57],"(CV).":[58],"For":[59,72],"AC-based":[60,107],"methods,":[61,74],"different":[62],"approaches":[63],"using":[64,151],"low-":[65],"high-frequency":[67],"measurement":[68],"techniques":[69,160],"are":[70],"considered.":[71],"DC-based":[73],"Wheatstone":[76,153],"bridge-based":[77,154],"approach":[78,155],"for":[79],"explored.":[83],"analysis":[85],"includes":[86],"data":[87],"collected":[88],"both":[89],"laboratory":[92],"field.":[96],"field":[98],"measurements":[99],"involve":[100],"over":[101],"50":[102],"custom":[103],"IoT":[104],"sensors":[105,120],"utilizing":[106],"deployed":[110],"various":[112],"environments.":[113],"results":[115],"indicate":[116],"that":[117],"while":[118],"can":[121],"detect":[122],"some":[123],"electrodes":[127],"due":[128],"corrosion,":[130],"confounding":[131],"variables":[132],"make":[133],"interpretation":[134],"challenging,":[135],"especially":[136],"environments":[138],"with":[139],"highly":[140],"volatile":[141],"corrosivity.":[142],"Additionally,":[143],"demonstrates":[146],"improvements":[147],"design":[150],"enhancements":[157],"through":[161],"voltammetry.":[163]},"counts_by_year":[],"updated_date":"2026-09-22T17:25:34.749102","created_date":"2025-10-10T00:00:00"}
