{"id":"https://openalex.org/W4408985477","doi":"https://doi.org/10.1016/j.applthermaleng.2025.126344","title":"Numerical simulation and experimental study of a novel emergency cooling system for thermal runaway propagation of power battery module","display_name":"Numerical simulation and experimental study of a novel emergency cooling system for thermal runaway propagation of power battery module","publication_year":2025,"publication_date":"2025-03-30","ids":{"openalex":"https://openalex.org/W4408985477","doi":"https://doi.org/10.1016/j.applthermaleng.2025.126344"},"language":"en","primary_location":{"id":"doi:10.1016/j.applthermaleng.2025.126344","doi":"https://doi.org/10.1016/j.applthermaleng.2025.126344","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.applthermaleng.2025.126344","pdf_url":null,"source":{"id":"https://openalex.org/S129676613","display_name":"Applied Thermal Engineering","issn_l":"1359-4311","issn":["1359-4311","1873-5606"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-3","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Applied Thermal Engineering","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049482582","display_name":"Shuyuan Jia","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210158664","display_name":"Dongfeng Motor (China)","ror":"https://ror.org/049j15k39","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210158664"]},{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shuyuan Jia","raw_affiliation_strings":["Dongfeng Motor Corporation Research & Development Institute, Wuhan 430101, China","Institute of Refrigeration and Cryogenics, Zhejiang University, 38 Zheda Road, Hangzhou, Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongfeng Motor Corporation Research & Development Institute, Wuhan 430101, China","institution_ids":["https://openalex.org/I4210158664"]},{"raw_affiliation_string":"Institute of Refrigeration and Cryogenics, Zhejiang University, 38 Zheda Road, Hangzhou, Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100400580","display_name":"Nian Li","orcid":"https://orcid.org/0000-0002-8532-1430","observed_orcids":["https://orcid.org/0000-0002-8532-1430"]},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Nian Li","raw_affiliation_strings":["Ningbo Research Institute, Zhejiang University, Ningbo 315100, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ningbo Research Institute, Zhejiang University, Ningbo 315100, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100319069","display_name":"Shuang Liu","orcid":"https://orcid.org/0000-0001-8148-1974","observed_orcids":["https://orcid.org/0000-0001-8148-1974"]},"institutions":[{"id":"https://openalex.org/I4210158664","display_name":"Dongfeng Motor (China)","ror":"https://ror.org/049j15k39","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210158664"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liu Shuang","raw_affiliation_strings":["Dongfeng Motor Corporation Research & Development Institute, Wuhan 430101, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongfeng Motor Corporation Research & Development Institute, Wuhan 430101, China","institution_ids":["https://openalex.org/I4210158664"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068799611","display_name":"Xu Zhang","orcid":"https://orcid.org/0000-0001-8651-8748","observed_orcids":["https://orcid.org/0000-0001-8651-8748","https://orcid.org/0000-0001-5080-8057"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xu Zhang","raw_affiliation_strings":["Xiangyang Da An Automobile Center Corporation Limited, Xiangyang 441004, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Xiangyang Da An Automobile Center Corporation Limited, Xiangyang 441004, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Fujing Tang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Fujing Tang","raw_affiliation_strings":["Xiangyang Da An Automobile Center Corporation Limited, Xiangyang 441004, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Xiangyang Da An Automobile Center Corporation Limited, Xiangyang 441004, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086080556","display_name":"Jing Wu","orcid":"https://orcid.org/0000-0002-6955-2087","observed_orcids":["https://orcid.org/0000-0002-6955-2087"]},"institutions":[{"id":"https://openalex.org/I4210158664","display_name":"Dongfeng Motor (China)","ror":"https://ror.org/049j15k39","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210158664"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"JieYu Wu","raw_affiliation_strings":["Dongfeng Motor Corporation Research & Development Institute, Wuhan 430101, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongfeng Motor Corporation Research & Development Institute, Wuhan 430101, China","institution_ids":["https://openalex.org/I4210158664"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5003560977","display_name":"Xiangguo Xu","orcid":"https://orcid.org/0000-0001-5158-3179","observed_orcids":["https://orcid.org/0000-0001-5158-3179"]},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiangguo Xu","raw_affiliation_strings":["Institute of Refrigeration and Cryogenics, Zhejiang University, 38 Zheda Road, Hangzhou, Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Refrigeration and Cryogenics, Zhejiang University, 38 Zheda Road, Hangzhou, Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5086080556","https://openalex.org/A5100400580"],"corresponding_institution_ids":["https://openalex.org/I4210158664","https://openalex.org/I76130692"],"apc_list":{"value":3660,"currency":"USD","value_usd":3660},"apc_paid":null,"fwci":2.4591,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.880645,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":99},"biblio":{"volume":"272","issue":null,"first_page":"126344","last_page":"126344"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10663","display_name":"Battery Modeling and Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10663","display_name":"Battery Modeling and Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10018","display_name":"Advancements in Battery Materials","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thermal-runaway","display_name":"thermal runaway","score":0.6620000004768372},{"id":"https://openalex.org/keywords/lithium-ion-battery-safety","display_name":"lithium-ion battery safety","score":0.7490000128746033},{"id":"https://openalex.org/keywords/ternary-lithium-batteries","display_name":"ternary lithium batteries","score":0.8339999914169312},{"id":"https://openalex.org/keywords/emergency-cooling-system","display_name":"emergency cooling system","score":0.8159999847412109},{"id":"https://openalex.org/keywords/spray-cooling","display_name":"spray cooling","score":0.9909999966621399},{"id":"https://openalex.org/keywords/refrigerant-injection","display_name":"refrigerant injection","score":0.8700000047683716},{"id":"https://openalex.org/keywords/r-134a","display_name":"R134a","score":0.972000002861023},{"id":"https://openalex.org/keywords/r227ea","display_name":"R227ea","score":0.996999979019165},{"id":"https://openalex.org/keywords/carbon-dioxide","display_name":"carbon dioxide","score":0.5690000057220459},{"id":"https://openalex.org/keywords/fire-suppression","display_name":"fire suppression","score":0.7059999704360962},{"id":"https://openalex.org/keywords/injection-mode","display_name":"injection mode","score":0.5389999747276306}],"concepts":[{"id":"https://openalex.org/C72688512","wikidata":"https://www.wikidata.org/wiki/Q908282","display_name":"Thermal runaway","level":4,"score":0.8429177403450012},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.6123741865158081},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5271909832954407},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.49840784072875977},{"id":"https://openalex.org/C500300565","wikidata":"https://www.wikidata.org/wiki/Q925667","display_name":"Computer simulation","level":2,"score":0.4892999827861786},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.46929246187210083},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40694206953048706},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.34594398736953735},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3395882546901703},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3227348327636719},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3210316598415375},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.25447946786880493},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.14415332674980164},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.12732791900634766},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11139464378356934}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.applthermaleng.2025.126344","doi":"https://doi.org/10.1016/j.applthermaleng.2025.126344","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.applthermaleng.2025.126344","pdf_url":null,"source":{"id":"https://openalex.org/S129676613","display_name":"Applied Thermal Engineering","issn_l":"1359-4311","issn":["1359-4311","1873-5606"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-3","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Applied Thermal Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":30,"referenced_works":["https://openalex.org/W1156684948","https://openalex.org/W2035039738","https://openalex.org/W2618037459","https://openalex.org/W2633593533","https://openalex.org/W2804673821","https://openalex.org/W2944510253","https://openalex.org/W2971834636","https://openalex.org/W2999683963","https://openalex.org/W3008069891","https://openalex.org/W3028119951","https://openalex.org/W3136191170","https://openalex.org/W3158904258","https://openalex.org/W3208707088","https://openalex.org/W4200433489","https://openalex.org/W4323051795","https://openalex.org/W4376627279","https://openalex.org/W4381050937","https://openalex.org/W4382359390","https://openalex.org/W4385372815","https://openalex.org/W4392977353","https://openalex.org/W4394912277","https://openalex.org/W4401354209","https://openalex.org/W4401502638","https://openalex.org/W4402081730","https://openalex.org/W4403089775","https://openalex.org/W4403141131","https://openalex.org/W4403147857","https://openalex.org/W4403156688","https://openalex.org/W4404869669","https://openalex.org/W6870762119"],"related_works":["https://openalex.org/W4368353887","https://openalex.org/W4386945966","https://openalex.org/W3157913336","https://openalex.org/W4405272084","https://openalex.org/W4313420614","https://openalex.org/W4408444015","https://openalex.org/W3208376964","https://openalex.org/W4200433489","https://openalex.org/W7168027852","https://openalex.org/W4309457596"],"abstract_inverted_index":null,"counts_by_year":[{"year":2026,"cited_by_count":10},{"year":2025,"cited_by_count":2}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2025-03-31T00:00:00"}
