{"id":"https://openalex.org/W4408536767","doi":"https://doi.org/10.1080/02286203.2025.2478988","title":"A switched inductor and voltage lift technique-based common ground non-isolated ultra-high gain DC-DC converter","display_name":"A switched inductor and voltage lift technique-based common ground non-isolated ultra-high gain DC-DC converter","alternate_titles":[],"publication_year":2025,"publication_date":"2025-03-16","ids":{"openalex":"https://openalex.org/W4408536767","doi":"https://doi.org/10.1080/02286203.2025.2478988"},"language":"en","primary_location":{"id":"doi:10.1080/02286203.2025.2478988","doi":"https://doi.org/10.1080/02286203.2025.2478988","is_oa":false,"landing_page_url":"https://doi.org/10.1080/02286203.2025.2478988","pdf_url":null,"source":{"id":"https://openalex.org/S79564839","display_name":"International Journal of Modelling and Simulation","issn_l":"0228-6203","issn":["0228-6203","1925-7082"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-d","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Modelling and Simulation","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W4408536767"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103259825","display_name":"Mohd Faraz Ahmad","orcid":"https://orcid.org/0000-0002-1559-0096","observed_orcids":["https://orcid.org/0000-0002-1559-0096"]},"institutions":[{"id":"https://openalex.org/I171210897","display_name":"Aligarh Muslim University","ror":"https://ror.org/03kw9gc02","country_code":"IN","type":"education","lineage":["https://openalex.org/I171210897"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Mohd Faraz Ahmad","raw_affiliation_strings":["Z.H. College of Engineering and Technology, Aligarh Muslim University, Aligarh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Z.H. College of Engineering and Technology, Aligarh Muslim University, Aligarh, India","institution_ids":["https://openalex.org/I171210897"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Prashant Varshney","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171210897","display_name":"Aligarh Muslim University","ror":"https://ror.org/03kw9gc02","country_code":"IN","type":"education","lineage":["https://openalex.org/I171210897"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Prashant Varshney","raw_affiliation_strings":["Z.H. College of Engineering and Technology, Aligarh Muslim University, Aligarh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Z.H. College of Engineering and Technology, Aligarh Muslim University, Aligarh, India","institution_ids":["https://openalex.org/I171210897"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040627359","display_name":"M. Saad Bin Arif","orcid":"https://orcid.org/0000-0002-6450-4940","observed_orcids":["https://orcid.org/0000-0002-6450-4940"]},"institutions":[{"id":"https://openalex.org/I171210897","display_name":"Aligarh Muslim University","ror":"https://ror.org/03kw9gc02","country_code":"IN","type":"education","lineage":["https://openalex.org/I171210897"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"M Saad Bin Arif","raw_affiliation_strings":["Z.H. College of Engineering and Technology, Aligarh Muslim University, Aligarh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Z.H. College of Engineering and Technology, Aligarh Muslim University, Aligarh, India","institution_ids":["https://openalex.org/I171210897"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5040627359"],"corresponding_institution_ids":["https://openalex.org/I171210897"],"apc_list":null,"apc_paid":null,"fwci":0.3462,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.43542508,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"18"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/high-gain-dc-dc-converter","display_name":"high-gain DC-DC converter","score":0.8730000257492065},{"id":"https://openalex.org/keywords/switched-inductor","display_name":"switched inductor","score":0.75},{"id":"https://openalex.org/keywords/voltage-lift-technique","display_name":"voltage lift technique","score":0.9580000042915344},{"id":"https://openalex.org/keywords/single-switch-topology","display_name":"single-switch topology","score":0.7699999809265137},{"id":"https://openalex.org/keywords/continuous-conduction-mode","display_name":"continuous conduction mode","score":0.8569999933242798},{"id":"https://openalex.org/keywords/photovoltaic-systems","display_name":"photovoltaic systems","score":0.746999979019165},{"id":"https://openalex.org/keywords/dc-microgrid","display_name":"DC microgrid","score":0.9629999995231628},{"id":"https://openalex.org/keywords/power-loss-analysis","display_name":"power loss analysis","score":0.9330000281333923},{"id":"https://openalex.org/keywords/converter-efficiency","display_name":"converter efficiency","score":0.6420000195503235}],"concepts":[{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.6241027116775513},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5162205696105957},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.490280419588089},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.4841464161872864},{"id":"https://openalex.org/C139002025","wikidata":"https://www.wikidata.org/wiki/Q3001212","display_name":"Lift (data mining)","level":2,"score":0.43135541677474976},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.4182947278022766},{"id":"https://openalex.org/C114825011","wikidata":"https://www.wikidata.org/wiki/Q440704","display_name":"Charge pump","level":4,"score":0.412007212638855},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.34581539034843445},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3451003432273865},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2861569821834564},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.2745633125305176},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.19743096828460693},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/02286203.2025.2478988","doi":"https://doi.org/10.1080/02286203.2025.2478988","is_oa":false,"landing_page_url":"https://doi.org/10.1080/02286203.2025.2478988","pdf_url":null,"source":{"id":"https://openalex.org/S79564839","display_name":"International Journal of Modelling and Simulation","issn_l":"0228-6203","issn":["0228-6203","1925-7082"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-d","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Modelling and Simulation","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8485000133514404,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":38,"referenced_works":["https://openalex.org/W2005205986","https://openalex.org/W2031106418","https://openalex.org/W2040457341","https://openalex.org/W2105639022","https://openalex.org/W2129189272","https://openalex.org/W2144287961","https://openalex.org/W2146432363","https://openalex.org/W2173544110","https://openalex.org/W2326797614","https://openalex.org/W2515895669","https://openalex.org/W2567400178","https://openalex.org/W2593065393","https://openalex.org/W2759925825","https://openalex.org/W2786091483","https://openalex.org/W2792114891","https://openalex.org/W2794359905","https://openalex.org/W2806483621","https://openalex.org/W2896822538","https://openalex.org/W2924468811","https://openalex.org/W2987784372","https://openalex.org/W3005089847","https://openalex.org/W3014386650","https://openalex.org/W3017010280","https://openalex.org/W3021572756","https://openalex.org/W3033010577","https://openalex.org/W3081254512","https://openalex.org/W3119264650","https://openalex.org/W3135637760","https://openalex.org/W3144025115","https://openalex.org/W3145882058","https://openalex.org/W3148990923","https://openalex.org/W3152785365","https://openalex.org/W3154675449","https://openalex.org/W3183223760","https://openalex.org/W3197946014","https://openalex.org/W3203778829","https://openalex.org/W4205962868","https://openalex.org/W4318954108"],"related_works":["https://openalex.org/W4411523529","https://openalex.org/W4391381693","https://openalex.org/W3197946014","https://openalex.org/W4296747769","https://openalex.org/W4283769830","https://openalex.org/W4391854953","https://openalex.org/W4388726479","https://openalex.org/W7128631660","https://openalex.org/W4313436884","https://openalex.org/W4389544653"],"abstract_inverted_index":{"This":[0],"paper":[1],"introduces":[2],"a":[3,15,18,23,30,92,114,120,126,145],"non-isolated,":[4],"single-switch":[5],"DC-DC":[6,72],"boost":[7],"converter":[8,28,65,85,144],"designed":[9],"to":[10,99],"achieve":[11],"ultra-high":[12],"gain":[13,116],"through":[14],"combination":[16],"of":[17,83,117,123,129,136],"voltage":[19,115,134,152],"lift":[20],"technique":[21],"and":[22,34,46,80,91,131,157],"switched":[24],"inductor":[25],"cell.":[26],"The":[27,78,106],"features":[29],"continuous":[31,55,154],"input":[32,155],"current":[33],"common":[35],"ground":[36],"configuration,":[37],"making":[38],"it":[39],"particularly":[40],"suitable":[41],"for":[42,148],"solar":[43],"PV":[44],"systems":[45],"DC":[47],"microgrid":[48],"applications.":[49,105],"Its":[50],"operation":[51],"is":[52,66,97],"analysed":[53],"in":[54],"conduction":[56],"mode":[57],"(CMM).":[58],"To":[59],"assess":[60],"its":[61,103],"performance,":[62],"the":[63,84,110,143],"proposed":[64,111],"compared":[67],"with":[68,125],"recently":[69],"developed":[70],"high-gain":[71],"converters":[73],"across":[74],"various":[75],"performance":[76,79],"metrics.":[77],"implementation":[81],"feasibility":[82],"are":[86],"validated":[87],"using":[88],"PLECS":[89],"Software,":[90],"detailed":[93],"power":[94],"loss":[95],"analysis":[96],"conducted":[98],"provide":[100],"insights":[101],"into":[102],"practical":[104],"results":[107],"demonstrate":[108],"that":[109],"topology":[112],"achieves":[113],"13":[118],"at":[119],"duty":[121],"ratio":[122],"0.5,":[124],"peak":[127],"efficiency":[128],"92.7%":[130],"an":[132],"output":[133],"ripple":[135],"less":[137],"than":[138],"1%.":[139],"These":[140],"characteristics":[141],"make":[142],"promising":[146],"solution":[147],"applications":[149],"requiring":[150],"high":[151,158],"gain,":[153],"current,":[156],"efficiency.":[159]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4408536767","counts_by_year":[{"year":2026,"cited_by_count":2}],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2025-03-18T00:00:00"}
