{"id":"https://openalex.org/W4408024167","doi":"https://doi.org/10.1049/icp.2024.4710","title":"Coordinated control of load tap changers and distributed energy resources for voltage regulation in active distribution systems","display_name":"Coordinated control of load tap changers and distributed energy resources for voltage regulation in active distribution systems","publication_year":2025,"publication_date":"2025-02-01","ids":{"openalex":"https://openalex.org/W4408024167","doi":"https://doi.org/10.1049/icp.2024.4710"},"language":"en","primary_location":{"id":"doi:10.1049/icp.2024.4710","doi":"https://doi.org/10.1049/icp.2024.4710","is_oa":false,"landing_page_url":"https://doi.org/10.1049/icp.2024.4710","pdf_url":null,"source":{"id":"https://openalex.org/S4404663355","display_name":"IET conference proceedings.","issn_l":"2732-4494","issn":["2732-4494"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Proceedings","raw_type":"journal-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022509790","display_name":"Vassilis C. Nikolaidis","orcid":"https://orcid.org/0000-0001-8616-2067","observed_orcids":["https://orcid.org/0000-0001-8616-2067"]},"institutions":[{"id":"https://openalex.org/I174458059","display_name":"National Technical University of Athens","ror":"https://ror.org/03cx6bg69","country_code":"GR","type":"education","lineage":["https://openalex.org/I174458059"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Vassilis C. Nikolaidis","raw_affiliation_strings":["School of Electrical and Computer Engineering, National Technical University of Athens"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, National Technical University of Athens","institution_ids":["https://openalex.org/I174458059"]}]},{"author_position":"last","author":{"id":null,"display_name":"Konstantinos Michailidis","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I147962203","display_name":"Democritus University of Thrace","ror":"https://ror.org/03bfqnx40","country_code":"GR","type":"education","lineage":["https://openalex.org/I147962203"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Konstantinos Michailidis","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Democritus University of Thrace, Xanthi, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Democritus University of Thrace, Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.02849913,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"2024","issue":"29","first_page":"504","last_page":"510"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.00139999995008111,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-control","display_name":"voltage regulation","score":0.7429999709129333},{"id":"https://openalex.org/keywords/on-load-tap-changer","display_name":"on-load tap changer","score":0.8999999761581421},{"id":"https://openalex.org/keywords/distributed-energy-resources","display_name":"distributed energy resources","score":0.9940000176429749},{"id":"https://openalex.org/keywords/active-distribution-networks","display_name":"active distribution networks","score":0.925000011920929},{"id":"https://openalex.org/keywords/coordinated-control","display_name":"coordinated control","score":0.824999988079071},{"id":"https://openalex.org/keywords/power-transformers","display_name":"power transformers","score":0.5220000147819519},{"id":"https://openalex.org/keywords/reactive-power-control","display_name":"reactive power control","score":0.718999981880188}],"concepts":[{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.6141074895858765},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.4956012964248657},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.48714372515678406},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.47086942195892334},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.34095993638038635},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.33704137802124023},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.31140559911727905},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2629542052745819},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25283560156822205},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.15245062112808228},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/icp.2024.4710","doi":"https://doi.org/10.1049/icp.2024.4710","is_oa":false,"landing_page_url":"https://doi.org/10.1049/icp.2024.4710","pdf_url":null,"source":{"id":"https://openalex.org/S4404663355","display_name":"IET conference proceedings.","issn_l":"2732-4494","issn":["2732-4494"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Proceedings","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9090999960899353,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"sustainable_development_goals_aurora":[{"score":0.8399999737739563,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1982160337","https://openalex.org/W1971380437","https://openalex.org/W2552681739","https://openalex.org/W3203098525","https://openalex.org/W2963705720","https://openalex.org/W1493463685","https://openalex.org/W2803899970","https://openalex.org/W3181887843","https://openalex.org/W2908392945","https://openalex.org/W2483001091"],"abstract_inverted_index":{"This":[0],"paper":[1],"introduces":[2],"a":[3,94],"voltage":[4,31,48,107,118,145,162],"control":[5,29,40,67,119,146],"method":[6,147,159],"for":[7],"active":[8,57,164],"distribution":[9,165],"systems":[10],"based":[11,44],"on":[12,45],"the":[13,37,56,75,79,82,97,100,106,157],"coordinated":[14],"operation":[15,77],"of":[16,62,81,99,126],"on-load-tap-changers":[17],"(OLTCs)":[18],"and":[19,50,135],"distributed":[20],"energy":[21],"resources":[22],"(DERs).":[23],"Primarily,":[24],"DERs":[25,140],"are":[26,42,86,141],"assigned":[27],"to":[28,71,89,108],"local":[30,47,91,117],"when":[32],"overvoltage/undervoltage":[33],"conditions":[34],"appear":[35],"in":[36,53,163],"system.":[38],"DER":[39,66],"actions":[41,120],"initiated":[43],"predetermined":[46],"criteria":[49],"they":[51],"result":[52],"properly":[54,87],"changing":[55],"and/or":[58],"reactive":[59],"power":[60,84,103],"output":[61],"DERs.":[63],"In":[64],"case":[65],"is":[68,121,148],"not":[69],"adequate":[70],"keep":[72,109],"voltages":[73,111],"within":[74,112],"acceptable":[76],"limits,":[78],"LTCs":[80],"MV/LV":[83],"transformers":[85],"controlled":[88],"restore":[90],"voltages.":[92],"As":[93],"tertiary":[95],"measure,":[96],"LTC":[98],"main":[101],"substation":[102],"transformer":[104],"regulates":[105],"network":[110],"permissible":[113],"limits.":[114],"Coordination":[115],"between":[116],"guaranteed":[122],"with":[123],"appropriate":[124],"selection":[125],"thresholds.":[127],"Several":[128],"scenarios":[129],"considering":[130],"hourly":[131],"time-varying":[132],"load":[133],"demand":[134],"variable":[136],"electricity":[137],"production":[138],"from":[139],"simulated.":[142],"The":[143],"proposed":[144,158],"tested":[149],"against":[150],"several":[151],"scenarios.":[152],"Simulation":[153],"results":[154],"show":[155],"that":[156],"efficiently":[160],"controls":[161],"systems.":[166]},"counts_by_year":[],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2025-10-10T00:00:00"}
