{"id":"https://openalex.org/W4404317455","doi":"https://doi.org/10.1109/sepoc63090.2024.10747432","title":"Reliability-Based Design of a 5 MWp Centralized Solar Photovoltaic Power Plant with Multi-String Inverters","display_name":"Reliability-Based Design of a 5 MWp Centralized Solar Photovoltaic Power Plant with Multi-String Inverters","alternate_titles":[],"publication_year":2024,"publication_date":"2024-10-20","ids":{"openalex":"https://openalex.org/W4404317455","doi":"https://doi.org/10.1109/sepoc63090.2024.10747432"},"language":"en","primary_location":{"id":"doi:10.1109/sepoc63090.2024.10747432","doi":"https://doi.org/10.1109/sepoc63090.2024.10747432","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sepoc63090.2024.10747432","pdf_url":null,"source":{"id":"https://openalex.org/S7407086986","display_name":"Seminar on Power Electronics and Control (SEPOC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 16th Seminar on Power Electronics and Control (SEPOC)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W4404317455"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5093314615","display_name":"Kamila Stromm","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Kamila Cassol Stromm","raw_affiliation_strings":["Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077014693","display_name":"Gabriel Henrique Danielsson","orcid":"https://orcid.org/0000-0003-4934-2960","observed_orcids":["https://orcid.org/0000-0003-4934-2960"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Gabriel Henrique Danielsson","raw_affiliation_strings":["Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5093327267","display_name":"Wilson Omar Ramos Parqui","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Wilson Omar Ramos Parqui","raw_affiliation_strings":["Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064575035","display_name":"Daniel Pinheiro Bernardon","orcid":"https://orcid.org/0000-0002-7952-1049","observed_orcids":["https://orcid.org/0000-0002-7952-1049"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Daniel Pinheiro Bernardon","raw_affiliation_strings":["Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010879861","display_name":"Alzenira da Rosa Abaide","orcid":"https://orcid.org/0000-0003-1043-1608","observed_orcids":["https://orcid.org/0000-0003-1043-1608"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Alzenira Da Rosa Abaide","raw_affiliation_strings":["Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5024106338","display_name":"Maur\u00edcio Sperandio","orcid":"https://orcid.org/0000-0003-4507-8437","observed_orcids":["https://orcid.org/0000-0003-4507-8437"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Mauricio Sperandio","raw_affiliation_strings":["Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria \u2013 UFSM,Center of Excellence in Energy and Power System (CEESP),Santa Maria,Brazil","institution_ids":["https://openalex.org/I33501960"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I33501960"],"apc_list":null,"apc_paid":null,"fwci":1.8744,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.82410316,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.7827000021934509,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.7827000021934509,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.19359999895095825,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.007000000216066837,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-based-design","display_name":"reliability-based design","score":0.8859999775886536},{"id":"https://openalex.org/keywords/photovoltaic-systems","display_name":"photovoltaic systems","score":0.6100000143051147},{"id":"https://openalex.org/keywords/capacity-factor","display_name":"capacity factor","score":0.9950000047683716},{"id":"https://openalex.org/keywords/inverter-sizing","display_name":"inverter sizing","score":0.6380000114440918},{"id":"https://openalex.org/keywords/solar-irradiation-data","display_name":"solar irradiation data","score":0.7630000114440918}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.8282864689826965},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7692173719406128},{"id":"https://openalex.org/C157486923","wikidata":"https://www.wikidata.org/wiki/Q1376436","display_name":"String (physics)","level":2,"score":0.6130358576774597},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5170522332191467},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5051305890083313},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.43673276901245117},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41550925374031067},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4040866792201996},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3881187438964844},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3039318919181824},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2790398597717285},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17160984873771667},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.11203739047050476},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sepoc63090.2024.10747432","doi":"https://doi.org/10.1109/sepoc63090.2024.10747432","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sepoc63090.2024.10747432","pdf_url":null,"source":{"id":"https://openalex.org/S7407086986","display_name":"Seminar on Power Electronics and Control (SEPOC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 16th Seminar on Power Electronics and Control (SEPOC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":1.0},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.8970999717712402},{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.4399999976158142}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1946456992","https://openalex.org/W2538459908","https://openalex.org/W3016941140","https://openalex.org/W3180525553","https://openalex.org/W3210026198"],"related_works":["https://openalex.org/W1976454286","https://openalex.org/W4388868475","https://openalex.org/W2340351820","https://openalex.org/W4292155114","https://openalex.org/W4406204609","https://openalex.org/W7009481736","https://openalex.org/W2201876509","https://openalex.org/W4392904905","https://openalex.org/W2766752952","https://openalex.org/W3205774954"],"abstract_inverted_index":{"Centralized":[0],"photovoltaic":[1,95],"solar":[2,9,57],"energy":[3,10],"plants":[4],"are":[5,43,52,77],"systems":[6],"for":[7,60,79],"converting":[8],"into":[11],"electricity,":[12],"concentrating":[13],"this":[14],"generation":[15],"process":[16],"in":[17,92],"a":[18,61],"single":[19],"location.":[20],"This":[21],"type":[22],"of":[23],"plant":[24],"presents":[25],"specific":[26,62],"characteristics":[27],"and":[28,30,40,74,90],"technical":[29],"regulatory":[31],"challenges":[32],"to":[33,45,87],"be":[34],"implemented.":[35],"Concepts":[36],"such":[37],"as":[38],"Reliability,":[39],"Multi-String":[41],"Arrangement":[42],"applied":[44],"ensure":[46],"system":[47],"reliability.":[48],"Furthermore,":[49],"sizing":[50],"methods":[51],"employed,":[53],"using":[54],"detailed":[55],"hourly":[56],"irradiation":[58],"data":[59],"region.":[63],"The":[64,83],"Capacity":[65,75],"Outage":[66],"Probability":[67],"Table":[68],"(COPT),":[69],"Expected":[70],"Supplied":[71],"Energy":[72],"(ESE),":[73],"Factor":[76],"calculated":[78],"each":[80],"case":[81],"study.":[82],"overall":[84],"objective":[85],"is":[86],"improve":[88],"understanding":[89],"efficiency":[91],"developing":[93],"centralized":[94],"plants.":[96]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4404317455","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2}],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2024-11-14T00:00:00"}