{"id":"https://openalex.org/W4403677458","doi":"https://doi.org/10.1109/uralcon62137.2024.10718881","title":"Reactive Power Control for Grid-Connected Inverters with PPWM at a Constant Modulation Index","display_name":"Reactive Power Control for Grid-Connected Inverters with PPWM at a Constant Modulation Index","publication_year":2024,"publication_date":"2024-09-27","ids":{"openalex":"https://openalex.org/W4403677458","doi":"https://doi.org/10.1109/uralcon62137.2024.10718881"},"language":"en","primary_location":{"id":"doi:10.1109/uralcon62137.2024.10718881","doi":"https://doi.org/10.1109/uralcon62137.2024.10718881","is_oa":false,"landing_page_url":"https://doi.org/10.1109/uralcon62137.2024.10718881","pdf_url":null,"source":{"id":"https://openalex.org/S4306498859","display_name":"International Ural Conference on Electrical Power Engineering (UralCon)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 International Ural Conference on Electrical Power Engineering (UralCon)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064893344","display_name":"Alexander S. Maklakov","orcid":"https://orcid.org/0000-0001-7950-708X","observed_orcids":["https://orcid.org/0000-0001-7950-708X"]},"institutions":[{"id":"https://openalex.org/I9115533","display_name":"Moscow Polytechnic University","ror":"https://ror.org/03paz2a60","country_code":"RU","type":"education","lineage":["https://openalex.org/I9115533"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"A. S. Maklakov","raw_affiliation_strings":["Moscow Polytechnic University,Department of Automation and Control,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Moscow Polytechnic University,Department of Automation and Control,Moscow,Russia","institution_ids":["https://openalex.org/I9115533"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5078982037","display_name":"Tatyana A. Lisovskaya","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I9115533","display_name":"Moscow Polytechnic University","ror":"https://ror.org/03paz2a60","country_code":"RU","type":"education","lineage":["https://openalex.org/I9115533"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"T. A. Lisovskaya","raw_affiliation_strings":["Moscow Polytechnic University,Department of Automation and Control,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Moscow Polytechnic University,Department of Automation and Control,Moscow,Russia","institution_ids":["https://openalex.org/I9115533"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I9115533"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.24532725,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"887","last_page":"890"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9243000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9243000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.03750000149011612,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.017500000074505806,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reactive-power-control","display_name":"reactive power control","score":0.9940000176429749},{"id":"https://openalex.org/keywords/grid-connected-inverter","display_name":"grid-connected inverter","score":1.0},{"id":"https://openalex.org/keywords/dc-link-voltage","display_name":"DC bus voltage","score":0.972000002861023},{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":0.9919999837875366},{"id":"https://openalex.org/keywords/inverter-control","display_name":"inverter control","score":0.6340000033378601}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6584597229957581},{"id":"https://openalex.org/C2777382242","wikidata":"https://www.wikidata.org/wiki/Q6017816","display_name":"Index (typography)","level":2,"score":0.5956730842590332},{"id":"https://openalex.org/C2776635522","wikidata":"https://www.wikidata.org/wiki/Q11883093","display_name":"Modulation index","level":4,"score":0.577242374420166},{"id":"https://openalex.org/C2777027219","wikidata":"https://www.wikidata.org/wiki/Q1284190","display_name":"Constant (computer programming)","level":2,"score":0.5592716932296753},{"id":"https://openalex.org/C123079801","wikidata":"https://www.wikidata.org/wiki/Q750240","display_name":"Modulation (music)","level":2,"score":0.5395158529281616},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.5327052474021912},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.48936551809310913},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.47625112533569336},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.4504474401473999},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.43784087896347046},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4354539215564728},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4264872074127197},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3210291564464569},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.28666532039642334},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2830384373664856},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.21472182869911194},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17874187231063843},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.11172893643379211},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C136764020","wikidata":"https://www.wikidata.org/wiki/Q466","display_name":"World Wide Web","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/uralcon62137.2024.10718881","doi":"https://doi.org/10.1109/uralcon62137.2024.10718881","is_oa":false,"landing_page_url":"https://doi.org/10.1109/uralcon62137.2024.10718881","pdf_url":null,"source":{"id":"https://openalex.org/S4306498859","display_name":"International Ural Conference on Electrical Power Engineering (UralCon)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 International Ural Conference on Electrical Power Engineering (UralCon)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.8970999717712402},{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.75}],"sustainable_development_goals_aurora":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8600000143051147}],"study_designs":[],"awards":[{"id":"https://openalex.org/G7438643962","display_name":null,"funder_award_id":"24-79-00003","funder_id":"https://openalex.org/F4320324099","funder_display_name":"Russian Science Foundation"}],"funders":[{"id":"https://openalex.org/F4320324099","display_name":"Russian Science Foundation","ror":"https://ror.org/03y2gwe85"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1975282630","https://openalex.org/W2163102330","https://openalex.org/W2428349791","https://openalex.org/W2793810649","https://openalex.org/W3097445121","https://openalex.org/W3141456309","https://openalex.org/W3178899799","https://openalex.org/W3203586239","https://openalex.org/W4226228177","https://openalex.org/W4301373562","https://openalex.org/W4379381382","https://openalex.org/W4388214279","https://openalex.org/W4388214372","https://openalex.org/W4388676592","https://openalex.org/W4399769064"],"related_works":["https://openalex.org/W2352428375","https://openalex.org/W2123843669","https://openalex.org/W2363948004","https://openalex.org/W2084806543","https://openalex.org/W2073153319","https://openalex.org/W2242959163","https://openalex.org/W2978977704","https://openalex.org/W2042468323","https://openalex.org/W2364031916","https://openalex.org/W2216276667"],"abstract_inverted_index":{"The":[0,29,82,105,118],"article":[1,83],"is":[2],"devoted":[3],"to":[4,56,91,124],"the":[5,32,43,58,62,85,93,96],"development":[6],"of":[7,14,71,88,95,115],"a":[8,25,68,78,113],"method":[9,100,120],"for":[10,40,101],"controlling":[11],"reactive":[12,34,44,72,102,108,126],"power":[13,35,45,73,103,109,127],"grid-connected":[15],"inverters":[16],"(GCIs)":[17],"with":[18,130],"pre-programmable":[19],"pulse":[20],"width":[21],"modulation":[22,27,51,80],"(PPWM)":[23],"at":[24,77,112],"constant":[26,79],"index.":[28,52,81],"paper":[30],"describes":[31],"GCI":[33,63,98,129],"control":[36,99],"modes,":[37],"mathematical":[38],"expressions":[39],"relationship":[41],"between":[42],"level,":[46],"DC":[47,64],"link":[48,65],"voltage,":[49],"and":[50],"It":[53],"allows":[54],"us":[55],"determine":[57],"required":[59,69],"voltage":[60],"in":[61],"that":[66],"provides":[67],"level":[70,114],"generation":[74],"or":[75],"consumption":[76],"presents":[84],"experimental":[86],"results":[87],"laboratory":[89],"studies":[90],"confirm":[92],"operability":[94],"proposed":[97],"control.":[104],"oscillograms":[106],"demonstrate":[107],"compensation":[110],"modes":[111],"10":[116],"kvar.":[117],"developed":[119],"can":[121],"be":[122],"used":[123],"compensate":[125],"by":[128],"PPWM.":[131]},"counts_by_year":[],"updated_date":"2026-10-05T09:50:58.205359","created_date":"2025-10-10T00:00:00"}
