{"id":"https://openalex.org/W4401011276","doi":"https://doi.org/10.1002/9781394226771.ch21","title":"Reliability Evaluation of Power Electronics Converters for Modern Power System Applications","display_name":"Reliability Evaluation of Power Electronics Converters for Modern Power System Applications","publication_year":2024,"publication_date":"2024-07-23","ids":{"openalex":"https://openalex.org/W4401011276","doi":"https://doi.org/10.1002/9781394226771.ch21"},"language":"en","primary_location":{"id":"doi:10.1002/9781394226771.ch21","doi":"https://doi.org/10.1002/9781394226771.ch21","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1002/9781394226771.ch21","pdf_url":null,"source":{"id":"https://openalex.org/S4306464293","display_name":"Wiley eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"ebook platform"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Reliability Analysis of Modern Power Systems","raw_type":"other"},"volume":{"id":"https://openalex.org/W4401011598","display_name":"Reliability Analysis of Modern Power Systems"},"type":"book-chapter","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039206084","display_name":"Amit Kumar","orcid":"https://orcid.org/0000-0002-0125-6759","observed_orcids":["https://orcid.org/0000-0002-0125-6759"]},"institutions":[{"id":"https://openalex.org/I4210127669","display_name":"Central Institute of Mining and Fuel Research","ror":"https://ror.org/03vkfy293","country_code":"IN","type":"facility","lineage":["https://openalex.org/I2799351866","https://openalex.org/I4210127669","https://openalex.org/I4210134808","https://openalex.org/I66760702"]},{"id":"https://openalex.org/I66760702","display_name":"Council of Scientific and Industrial Research","ror":"https://ror.org/021wm7p51","country_code":"IN","type":"government","lineage":["https://openalex.org/I2799351866","https://openalex.org/I4210134808","https://openalex.org/I66760702"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Amit Kumar","raw_affiliation_strings":["Flameproof and Equipment Safety Department, CSIR-Central Institute of Mining and Fuel Research, Dhanbad, Jharkhand, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Flameproof and Equipment Safety Department, CSIR-Central Institute of Mining and Fuel Research, Dhanbad, Jharkhand, India","institution_ids":["https://openalex.org/I4210127669","https://openalex.org/I66760702"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090774290","display_name":"Sachin Kumar","orcid":"https://orcid.org/0000-0003-1517-7450","observed_orcids":["https://orcid.org/0000-0003-1517-7450"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sachin Kumar","raw_affiliation_strings":["Department of Electrical Engineering, G.B. Pant Institute of Engineering and Technology, Pauri-Garhwal, Uttarakhand, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, G.B. Pant Institute of Engineering and Technology, Pauri-Garhwal, Uttarakhand, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Sunil K. Singh","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210106473","display_name":"Shri Ramswaroop Memorial University","ror":"https://ror.org/011nk9770","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210106473"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sunil K. Singh","raw_affiliation_strings":["Department of Electrical Engineering, Shri Ramswaroop Memorial University, Lucknow, Uttar Pradesh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Shri Ramswaroop Memorial University, Lucknow, Uttar Pradesh, India","institution_ids":["https://openalex.org/I4210106473"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011135506","display_name":"Ram Khelawan Saket","orcid":"https://orcid.org/0000-0002-2773-9599","observed_orcids":["https://orcid.org/0000-0002-2773-9599"]},"institutions":[{"id":"https://openalex.org/I56404289","display_name":"Indian Institute of Technology BHU","ror":"https://ror.org/01kh5gc44","country_code":"IN","type":"education","lineage":["https://openalex.org/I56404289","https://openalex.org/I91357014"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"R. K. Saket","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India","institution_ids":["https://openalex.org/I56404289"]}]},{"author_position":"last","author":{"id":null,"display_name":"P. Sanjeevikumar","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2801380234","display_name":"University of South-Eastern Norway","ror":"https://ror.org/05ecg5h20","country_code":"NO","type":"education","lineage":["https://openalex.org/I2801380234"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"P. Sanjeevikumar","raw_affiliation_strings":["Department of Electrical Engineering, IT and Cybernetics, University of South-Eastern Norway, Porsgrunn, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, IT and Cybernetics, University of South-Eastern Norway, Porsgrunn, Norway","institution_ids":["https://openalex.org/I2801380234"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.961,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.92336683,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"409","last_page":"425"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.6035000085830688,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.6035000085830688,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.22339999675750732,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.040699999779462814,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-converters","display_name":"power converters","score":0.8859999775886536},{"id":"https://openalex.org/keywords/reliability-analysis","display_name":"reliability analysis","score":0.8330000042915344},{"id":"https://openalex.org/keywords/semiconductor-devices","display_name":"semiconductor devices","score":0.8109999895095825},{"id":"https://openalex.org/keywords/temperature-dependence","display_name":"temperature dependence","score":0.6970000267028809},{"id":"https://openalex.org/keywords/wear-out-failure","display_name":"wear-out failure","score":0.8500000238418579},{"id":"https://openalex.org/keywords/catastrophic-failure","display_name":"catastrophic failure","score":0.9900000095367432},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.875},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.7730000019073486},{"id":"https://openalex.org/keywords/reliability-modeling","display_name":"reliability modeling","score":0.6740000247955322},{"id":"https://openalex.org/keywords/hvdc-transmission","display_name":"HVDC transmission","score":0.8059999942779541},{"id":"https://openalex.org/keywords/markov-model","display_name":"Markov model","score":0.8560000061988831},{"id":"https://openalex.org/keywords/mission-profile","display_name":"mission profile","score":0.9380000233650208}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.8771164417266846},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7854765057563782},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.6736167669296265},{"id":"https://openalex.org/C2778306610","wikidata":"https://www.wikidata.org/wiki/Q7189696","display_name":"Physics of failure","level":4,"score":0.6078898310661316},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5768716335296631},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5721429586410522},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5709596276283264},{"id":"https://openalex.org/C138331895","wikidata":"https://www.wikidata.org/wiki/Q11650","display_name":"Electronics","level":2,"score":0.5418710112571716},{"id":"https://openalex.org/C141812795","wikidata":"https://www.wikidata.org/wiki/Q7236534","display_name":"Power module","level":3,"score":0.4858214855194092},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.4837105870246887},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4776645600795746},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47146397829055786},{"id":"https://openalex.org/C129014197","wikidata":"https://www.wikidata.org/wiki/Q906544","display_name":"Power semiconductor device","level":3,"score":0.43110769987106323},{"id":"https://openalex.org/C112987892","wikidata":"https://www.wikidata.org/wiki/Q5051574","display_name":"Catastrophic failure","level":2,"score":0.4310457110404968},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3914702534675598},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3770468533039093},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3700439929962158},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.10540243983268738},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1002/9781394226771.ch21","doi":"https://doi.org/10.1002/9781394226771.ch21","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1002/9781394226771.ch21","pdf_url":null,"source":{"id":"https://openalex.org/S4306464293","display_name":"Wiley eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"ebook platform"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Reliability Analysis of Modern Power Systems","raw_type":"other"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8485000133514404},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2091749383","https://openalex.org/W2205144585","https://openalex.org/W2253810749","https://openalex.org/W2287880634","https://openalex.org/W2559456120","https://openalex.org/W2810050724","https://openalex.org/W3007156019","https://openalex.org/W3171021970","https://openalex.org/W4321386663","https://openalex.org/W4322503318","https://openalex.org/W4353073415","https://openalex.org/W4391951222"],"related_works":["https://openalex.org/W2999595761","https://openalex.org/W4415403479","https://openalex.org/W2196204847","https://openalex.org/W7160515868","https://openalex.org/W7163875501","https://openalex.org/W2524851711","https://openalex.org/W2770240868","https://openalex.org/W4313191170","https://openalex.org/W2964542908","https://openalex.org/W3012466011"],"abstract_inverted_index":{"The":[0,30,68,89],"study":[1],"of":[2,13,21,32,71,92],"power":[3,15,40,93,103],"electronic":[4,94],"converters'":[5],"reliability":[6,90],"is":[7,49,75],"essential":[8],"for":[9],"the":[10,22,78],"uninterrupted":[11],"operation":[12],"contemporary":[14,39],"systems.":[16],"Semiconductor":[17],"devices":[18],"are":[19,105],"one":[20],"converter":[23],"components":[24],"most":[25],"susceptible":[26],"to":[27,80],"temperature":[28],"changes.":[29],"performance":[31],"converters":[33],"in":[34,77],"various":[35],"applications,":[36],"such":[37],"as":[38],"systems":[41,104],"and":[42,56,61,101,113],"high-voltage":[43],"direct":[44],"current":[45],"(HVDC)":[46],"transmission":[47],"lines,":[48],"also":[50,106],"significantly":[51],"impacted":[52],"by":[53],"random":[54],"chance":[55],"wear-out":[57,62],"failures.":[58],"Catastrophic":[59],"failure":[60,63],"have":[64],"been":[65],"addressed":[66],"briefly.":[67],"condition":[69],"monitoring":[70],"temperature-dependent":[72],"electrical":[73],"parameters":[74],"covered":[76],"chapter":[79],"identify":[81],"faults":[82],"before":[83],"junction":[84],"temperatures":[85],"reach":[86],"dangerous":[87],"levels.":[88],"modeling":[91],"converters,":[95],"HVDC":[96],"systems,":[97,100],"wind":[98],"farm":[99],"modern":[102],"discussed":[107],"with":[108],"mission":[109],"profiles,":[110],"historical":[111],"data,":[112],"Markov's":[114],"models.":[115]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2024-07-27T00:00:00"}
