{"id":"https://openalex.org/W4400101002","doi":"https://doi.org/10.36001/phme.2024.v8i1.4017","title":"Towards a Hybrid Framework for Prognostics with Limited Run-to-Failure Data","display_name":"Towards a Hybrid Framework for Prognostics with Limited Run-to-Failure Data","publication_year":2024,"publication_date":"2024-06-26","ids":{"openalex":"https://openalex.org/W4400101002","doi":"https://doi.org/10.36001/phme.2024.v8i1.4017"},"language":"en","primary_location":{"id":"doi:10.36001/phme.2024.v8i1.4017","doi":"https://doi.org/10.36001/phme.2024.v8i1.4017","is_oa":true,"landing_page_url":"https://doi.org/10.36001/phme.2024.v8i1.4017","pdf_url":"https://papers.phmsociety.org/index.php/phme/article/download/4017/2465","source":{"id":"https://openalex.org/S4387281558","display_name":"PHM Society European Conference","issn_l":"2325-016X","issn":["2325-016X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"PHM Society European Conference","raw_type":"journal-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://papers.phmsociety.org/index.php/phme/article/download/4017/2465","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5019393881","display_name":"Luc S. Keizers","orcid":"https://orcid.org/0000-0002-3406-9263","observed_orcids":["https://orcid.org/0000-0002-3406-9263"]},"institutions":[{"id":"https://openalex.org/I4210119716","display_name":"Netherlands Defence Academy","ror":"https://ror.org/02dnvjf04","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210094335","https://openalex.org/I4210119716","https://openalex.org/I4210140876"]},{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Luc Keizers","raw_affiliation_strings":["University of Twente, Netherlands Defence Academy"],"raw_orcid":"https://orcid.org/0000-0002-3406-9263","affiliations":[{"raw_affiliation_string":"University of Twente, Netherlands Defence Academy","institution_ids":["https://openalex.org/I4210119716","https://openalex.org/I94624287"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082177890","display_name":"Richard Loendersloot","orcid":"https://orcid.org/0000-0002-1113-8203","observed_orcids":["https://orcid.org/0000-0002-1113-8203","https://orcid.org/0000-0003-1926-7250"]},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Richard Loendersloot","raw_affiliation_strings":["University of Twente"],"raw_orcid":"https://orcid.org/0000-0002-1113-8203","affiliations":[{"raw_affiliation_string":"University of Twente","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5036373732","display_name":"Tiedo Tinga","orcid":"https://orcid.org/0000-0001-6600-5099","observed_orcids":["https://orcid.org/0000-0001-6600-5099"]},"institutions":[{"id":"https://openalex.org/I4210119716","display_name":"Netherlands Defence Academy","ror":"https://ror.org/02dnvjf04","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210094335","https://openalex.org/I4210119716","https://openalex.org/I4210140876"]},{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Tiedo Tinga","raw_affiliation_strings":["University of Twente, Netherlands Defence Academy"],"raw_orcid":"https://orcid.org/0000-0001-6600-5099","affiliations":[{"raw_affiliation_string":"University of Twente, Netherlands Defence Academy","institution_ids":["https://openalex.org/I4210119716","https://openalex.org/I94624287"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.8091,"has_fulltext":true,"cited_by_count":6,"citation_normalized_percentile":{"value":0.94986764,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":95,"max":97},"biblio":{"volume":"8","issue":"1","first_page":"12","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.8730000257492065,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.8730000257492065,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.10109999775886536,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.015399999916553497,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/prognostics","display_name":"prognostics","score":0.9729999899864197},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":0.7200000286102295},{"id":"https://openalex.org/keywords/run-to-failure-data","display_name":"run-to-failure data","score":0.8640000224113464},{"id":"https://openalex.org/keywords/damage-quantification","display_name":"damage quantification","score":0.8220000267028809},{"id":"https://openalex.org/keywords/bayesian-filtering","display_name":"Bayesian filtering","score":0.7559999823570251},{"id":"https://openalex.org/keywords/system-model","display_name":"system model","score":0.609000027179718},{"id":"https://openalex.org/keywords/cyber-physical-systems","display_name":"cyber-physical systems","score":0.7829999923706055},{"id":"https://openalex.org/keywords/real-world-case-studies","display_name":"real-world case studies","score":0.5460000038146973}],"concepts":[{"id":"https://openalex.org/C129364497","wikidata":"https://www.wikidata.org/wiki/Q3042561","display_name":"Prognostics","level":2,"score":0.8991049528121948},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.519062340259552},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5041035413742065},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2588130831718445}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.36001/phme.2024.v8i1.4017","doi":"https://doi.org/10.36001/phme.2024.v8i1.4017","is_oa":true,"landing_page_url":"https://doi.org/10.36001/phme.2024.v8i1.4017","pdf_url":"https://papers.phmsociety.org/index.php/phme/article/download/4017/2465","source":{"id":"https://openalex.org/S4387281558","display_name":"PHM Society European Conference","issn_l":"2325-016X","issn":["2325-016X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"PHM Society European Conference","raw_type":"journal-article"},{"id":"pmh:oai:ris.utwente.nl:openaire/d8702675-11b0-4391-965e-1716e500df02","doi":null,"is_oa":true,"landing_page_url":"https://research.utwente.nl/en/publications/d8702675-11b0-4391-965e-1716e500df02","pdf_url":null,"source":{"id":"https://openalex.org/S4406922991","display_name":"University of Twente Research Information","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Keizers, L S, Loendersloot, R & Tinga, T 2024, Towards a Hybrid Framework For Prognostics With Limited Run-to-Failure Data. in Proceedings of the 8th European Conference of the Prognostics and Health Management Society 2024. 1 edn, vol. 8, PHM Society, pp. 844-855, 8th European Conference of the Prognostics and Health Management Society, PHME 2024, Prague, Czech Republic, 3/07/24. https://doi.org/10.36001/phme.2024.v8i1.4017","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"doi:10.36001/phme.2024.v8i1.4017","doi":"https://doi.org/10.36001/phme.2024.v8i1.4017","is_oa":true,"landing_page_url":"https://doi.org/10.36001/phme.2024.v8i1.4017","pdf_url":"https://papers.phmsociety.org/index.php/phme/article/download/4017/2465","source":{"id":"https://openalex.org/S4387281558","display_name":"PHM Society European Conference","issn_l":"2325-016X","issn":["2325-016X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"PHM Society European Conference","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G2039356335","display_name":null,"funder_award_id":"1160.18.238","funder_id":"https://openalex.org/F4320321800","funder_display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek"},{"id":"https://openalex.org/G4371345817","display_name":"PrimaVera: Predictive maintenance for Very effective asset management","funder_award_id":"NWA.1160.18.238","funder_id":"https://openalex.org/F4320321800","funder_display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek"}],"funders":[{"id":"https://openalex.org/F4320321800","display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","ror":"https://ror.org/04jsz6e67"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4400101002.pdf","grobid_xml":"https://content.openalex.org/works/W4400101002.grobid-xml"},"referenced_works_count":26,"referenced_works":["https://openalex.org/W109326644","https://openalex.org/W1990351237","https://openalex.org/W2014297929","https://openalex.org/W2085968292","https://openalex.org/W2086005219","https://openalex.org/W2088638930","https://openalex.org/W2150606224","https://openalex.org/W2498933636","https://openalex.org/W2557776107","https://openalex.org/W2765186183","https://openalex.org/W2972588210","https://openalex.org/W3008011500","https://openalex.org/W3015427583","https://openalex.org/W3109012693","https://openalex.org/W3111183960","https://openalex.org/W3119743098","https://openalex.org/W3129094303","https://openalex.org/W3170962134","https://openalex.org/W3211871963","https://openalex.org/W4206759640","https://openalex.org/W4210516747","https://openalex.org/W4210558868","https://openalex.org/W4214900601","https://openalex.org/W4307715538","https://openalex.org/W4380318218","https://openalex.org/W4385986457"],"related_works":["https://openalex.org/W4408448812","https://openalex.org/W4285106116","https://openalex.org/W2557776107","https://openalex.org/W7098231889","https://openalex.org/W7152481968","https://openalex.org/W7052125201","https://openalex.org/W4403325354","https://openalex.org/W1432388788","https://openalex.org/W2144779807","https://openalex.org/W2593519057"],"abstract_inverted_index":{"The":[0,113],"introduction":[1],"of":[2,8,14,26,75,88,94,116,154],"cyber-physical":[3],"systems":[4],"with":[5,54],"increased":[6],"availability":[7],"sensor":[9],"data":[10,38],"creates":[11],"a":[12,24,47,84,92,102,117],"lot":[13,25],"research":[15],"interest":[16],"in":[17,126,147],"prognostic":[18,61,80],"algorithms":[19,27],"for":[20,137,145,167],"predictive":[21],"maintenance.":[22],"Although":[23],"are":[28,70],"successfully":[29],"applied":[30],"to":[31,83],"benchmark":[32,51],"case":[33,52,57],"studies":[34,53,58],"based":[35,59,139],"on":[36,60,109,140],"simulated":[37],"and":[39,65,77,152],"experimental":[40],"set-ups,":[41],"deploymentin":[42],"industry":[43],"lags":[44],"behind.":[45],"From":[46],"comparison":[48],"between":[49],"three":[50],"two":[55,67],"real-world":[56],"metrics":[62,81],"(monotonicity,":[63],"prognosability":[64],"trendability),":[66],"main":[68],"issues":[69],"observed:":[71],"1)":[72],"the":[73,155,162],"lack":[74],"run-to-failures":[76],"2)":[78],"low":[79,85],"due":[82],"signal-to-noise":[86],"ratio":[87],"degradation":[89],"trends,":[90],"as":[91],"result":[93],"unexplained":[95],"physical":[96],"phenomena.":[97],"To":[98],"make":[99],"prognostics":[100,138,144],"feasible,":[101],"hybrid":[103],"framework":[104,114,156,163],"is":[105,129],"proposed":[106],"that":[107],"focuses":[108],"improving":[110],"system":[111,124],"knowledge.":[112],"consists":[115],"quantitative":[118,132],"diagnostic":[119],"assessments,":[120],"guided":[121],"by":[122],"(modular)":[123],"models":[125],"which":[127],"damage":[128,133],"induced.":[130],"This":[131],"assessment":[134],"provides":[135],"input":[136],"Bayesian":[141],"filtering,":[142],"enabling":[143],"assets":[146],"varying":[148],"operational":[149],"conditions.":[150],"Implementation":[151],"validation":[153],"requires":[157],"investments,":[158],"but":[159],"modularity":[160],"within":[161],"can":[164],"accelerate":[165],"development":[166],"new":[168],"systems.":[169]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":3}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2024-06-28T00:00:00"}
