{"id":"https://openalex.org/W4394597709","doi":"https://doi.org/10.1109/crc60659.2023.10488576","title":"220kV Explosion-proof High-voltage Cable Joint end Folding Corner Design","display_name":"220kV Explosion-proof High-voltage Cable Joint end Folding Corner Design","publication_year":2024,"publication_date":"2024-04-09","ids":{"openalex":"https://openalex.org/W4394597709","doi":"https://doi.org/10.1109/crc60659.2023.10488576"},"language":"en","primary_location":{"id":"doi:10.1109/crc60659.2023.10488576","doi":"https://doi.org/10.1109/crc60659.2023.10488576","is_oa":false,"landing_page_url":"https://doi.org/10.1109/crc60659.2023.10488576","pdf_url":null,"source":{"id":"https://openalex.org/S7407086648","display_name":"International Conference on Control, Robotics and Cybernetics (CRC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 8th International Conference on Control, Robotics and Cybernetics (CRC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Qiu Wei","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Qiu Wei","raw_affiliation_strings":["Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100379239","display_name":"Li Chen","orcid":"https://orcid.org/0000-0002-3769-1488","observed_orcids":["https://orcid.org/0000-0002-3769-1488"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Li Chen","raw_affiliation_strings":["Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103668709","display_name":"Huang Yu-hua","orcid":"https://orcid.org/0000-0001-6761-1189","observed_orcids":["https://orcid.org/0000-0001-6761-1189"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Huang Yuhua","raw_affiliation_strings":["Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109703171","display_name":"Cui Jiangjing","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Cui Jiangjing","raw_affiliation_strings":["Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhuhai Power Supply Bureau Guangdong Power Grid Limited Liability Company, Zhuhai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Gao Xiang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I56934997","display_name":"Changsha University of Science and Technology","ror":"https://ror.org/03yph8055","country_code":"CN","type":"education","lineage":["https://openalex.org/I56934997"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Gao Xiang","raw_affiliation_strings":["School of Electrical & Information Engineering Changsha University of Science & Technology,Changsha,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical & Information Engineering Changsha University of Science & Technology,Changsha,China","institution_ids":["https://openalex.org/I56934997"]}]},{"author_position":"last","author":{"id":null,"display_name":"Yang Xin","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I56934997","display_name":"Changsha University of Science and Technology","ror":"https://ror.org/03yph8055","country_code":"CN","type":"education","lineage":["https://openalex.org/I56934997"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yang Xin","raw_affiliation_strings":["School of Electrical & Information Engineering Changsha University of Science & Technology,Changsha,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical & Information Engineering Changsha University of Science & Technology,Changsha,China","institution_ids":["https://openalex.org/I56934997"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.3044,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.66916103,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"182","last_page":"185"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14156","display_name":"Engineering Applied Research","score":0.5288000106811523,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14156","display_name":"Engineering Applied Research","score":0.5288000106811523,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.3953000009059906,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11874","display_name":"Structural Response to Dynamic Loads","score":0.007899999618530273,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cable-joints","display_name":"cable joints","score":0.8230000138282776},{"id":"https://openalex.org/keywords/stress-concentration","display_name":"stress concentration","score":0.7950000166893005},{"id":"https://openalex.org/keywords/bending-angle","display_name":"bending angle","score":0.765999972820282},{"id":"https://openalex.org/keywords/short-circuit-arc","display_name":"short-circuit arc","score":0.7179999947547913},{"id":"https://openalex.org/keywords/multi-physics-coupling","display_name":"multi-physics coupling","score":0.8140000104904175},{"id":"https://openalex.org/keywords/stress-concentration-coefficient","display_name":"stress concentration coefficient","score":0.7820000052452087},{"id":"https://openalex.org/keywords/joint-design","display_name":"joint design","score":0.45399999618530273}],"concepts":[{"id":"https://openalex.org/C18555067","wikidata":"https://www.wikidata.org/wiki/Q8375051","display_name":"Joint (building)","level":2,"score":0.7355555295944214},{"id":"https://openalex.org/C2776545253","wikidata":"https://www.wikidata.org/wiki/Q5464292","display_name":"Folding (DSP implementation)","level":2,"score":0.6565552949905396},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.5114216208457947},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4962075352668762},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4348345994949341},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.35005873441696167},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3293887972831726}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/crc60659.2023.10488576","doi":"https://doi.org/10.1109/crc60659.2023.10488576","is_oa":false,"landing_page_url":"https://doi.org/10.1109/crc60659.2023.10488576","pdf_url":null,"source":{"id":"https://openalex.org/S7407086648","display_name":"International Conference on Control, Robotics and Cybernetics (CRC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 8th International Conference on Control, Robotics and Cybernetics (CRC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.428600013256073,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320323192","display_name":"China Southern Power Grid","ror":"https://ror.org/03hkh9419"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2165829331","https://openalex.org/W2347364753","https://openalex.org/W2391564918","https://openalex.org/W3043028951","https://openalex.org/W3201233696"],"related_works":["https://openalex.org/W4394647868","https://openalex.org/W4394598030","https://openalex.org/W4394597713","https://openalex.org/W4394829233","https://openalex.org/W4415623100","https://openalex.org/W4404814512","https://openalex.org/W4280499128","https://openalex.org/W7158848227","https://openalex.org/W4408657298","https://openalex.org/W4415623072"],"abstract_inverted_index":{"To":[0],"solve":[1],"the":[2,6,9,12,18,23,27,30,34,39,51,57,68,74,79,83,87,91,95],"stress":[3,31,52,58,75],"concentration":[4,53,59,76],"at":[5,33,60,90],"corner":[7],"of":[8,11,86,97],"end":[10,92],"explosion-proof":[13,98],"high-voltage":[14,35,99],"cable":[15,36,100],"joint":[16,37],"when":[17,38,67],"explosion":[19,40],"is":[20,71,78],"caused":[21],"by":[22,42],"short":[24],"circuit":[25],"arc,":[26],"paper":[28],"calculated":[29],"distribution":[32],"occurs":[41],"multi-physics":[43],"coupling":[44],"and":[45,55],"finite":[46],"element":[47],"calculation.":[48],"By":[49],"calculating":[50],"coefficient":[54,77],"comparing":[56],"different":[61],"angles,":[62],"it":[63],"was":[64],"concluded":[65],"that":[66],"bending":[69,88],"Angle":[70,89],"about":[72],"122\u00b0,":[73],"smallest,":[80],"which":[81],"provides":[82],"design":[84,96],"scheme":[85],"part":[93],"for":[94],"joint.":[101]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2024-04-10T00:00:00"}