{"id":"https://openalex.org/W4394523935","doi":"https://doi.org/10.6084/m9.figshare.21431305","title":"Nonlinear Numerical Evaluation of Dry Precast Beam Column Connection with Embedded Bolts","display_name":"Nonlinear Numerical Evaluation of Dry Precast Beam Column Connection with Embedded Bolts","publication_year":2022,"publication_date":"2022-01-01","ids":{"openalex":"https://openalex.org/W4394523935","doi":"https://doi.org/10.6084/m9.figshare.21431305"},"language":"en","primary_location":{"id":"pmh:oai:figshare.com:article/21431305","doi":null,"is_oa":true,"landing_page_url":"https://figshare.com/articles/dataset/Nonlinear_Numerical_Evaluation_of_Dry_Precast_Beam_Column_Connection_with_Embedded_Bolts/21431305","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Dataset"},"volume":null,"type":"dataset","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://figshare.com/articles/dataset/Nonlinear_Numerical_Evaluation_of_Dry_Precast_Beam_Column_Connection_with_Embedded_Bolts/21431305","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075567968","display_name":"K. Srikanth","orcid":"https://orcid.org/0000-0003-4520-3437","observed_orcids":["https://orcid.org/0000-0003-4520-3437"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kallam, Srikanth","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5039939782","display_name":"Sanjay. BhanuKumar Borghate","orcid":"https://orcid.org/0000-0003-2874-5832","observed_orcids":["https://orcid.org/0000-0003-2874-5832"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Borghate, Sanjay. BhanuKumar","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.9648000001907349,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.9648000001907349,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10713","display_name":"Structural Load-Bearing Analysis","score":0.016200000420212746,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.010499999858438969,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/precast-concrete","display_name":"precast concrete","score":0.574999988079071},{"id":"https://openalex.org/keywords/dry-connections","display_name":"dry connections","score":0.746999979019165},{"id":"https://openalex.org/keywords/beam-column-joints","display_name":"beam-column joints","score":0.8820000290870667},{"id":"https://openalex.org/keywords/nonlinear-finite-element-analysis","display_name":"nonlinear finite element analysis","score":0.8349999785423279},{"id":"https://openalex.org/keywords/joint-rigidity","display_name":"joint rigidity","score":0.7139999866485596},{"id":"https://openalex.org/keywords/stiffness-degradation","display_name":"stiffness degradation","score":0.8769999742507935},{"id":"https://openalex.org/keywords/energy-dissipation","display_name":"energy dissipation","score":0.9980000257492065},{"id":"https://openalex.org/keywords/failure-modes","display_name":"failure modes","score":0.9490000009536743},{"id":"https://openalex.org/keywords/seismic-design","display_name":"seismic design","score":0.8399999737739563}],"concepts":[{"id":"https://openalex.org/C125450124","wikidata":"https://www.wikidata.org/wiki/Q831541","display_name":"Precast concrete","level":2,"score":0.962037980556488},{"id":"https://openalex.org/C2780551164","wikidata":"https://www.wikidata.org/wiki/Q2306599","display_name":"Column (typography)","level":3,"score":0.654233992099762},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.5491518974304199},{"id":"https://openalex.org/C13355873","wikidata":"https://www.wikidata.org/wiki/Q2920850","display_name":"Connection (principal bundle)","level":2,"score":0.5468544363975525},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.5285726189613342},{"id":"https://openalex.org/C168834538","wikidata":"https://www.wikidata.org/wiki/Q3705329","display_name":"Beam (structure)","level":2,"score":0.45250144600868225},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3477064371109009},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3389321565628052},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.082781583070755},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"pmh:oai:figshare.com:article/21431305","doi":null,"is_oa":true,"landing_page_url":"https://figshare.com/articles/dataset/Nonlinear_Numerical_Evaluation_of_Dry_Precast_Beam_Column_Connection_with_Embedded_Bolts/21431305","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Dataset"},{"id":"doi:10.6084/m9.figshare.21431305","doi":"https://doi.org/10.6084/m9.figshare.21431305","is_oa":true,"landing_page_url":"https://doi.org/10.6084/m9.figshare.21431305","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Dataset"},{"id":"doi:10.6084/m9.figshare.21431305.v1","doi":"https://doi.org/10.6084/m9.figshare.21431305.v1","is_oa":true,"landing_page_url":"https://doi.org/10.6084/m9.figshare.21431305.v1","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Dataset"}],"best_oa_location":{"id":"pmh:oai:figshare.com:article/21431305","doi":null,"is_oa":true,"landing_page_url":"https://figshare.com/articles/dataset/Nonlinear_Numerical_Evaluation_of_Dry_Precast_Beam_Column_Connection_with_Embedded_Bolts/21431305","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Dataset"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4213022682","https://openalex.org/W2969456814","https://openalex.org/W2397014251","https://openalex.org/W4379117365","https://openalex.org/W2240398811","https://openalex.org/W4409436062","https://openalex.org/W4414478043","https://openalex.org/W4396868621","https://openalex.org/W4294783753","https://openalex.org/W2802174355"],"abstract_inverted_index":{"Abstract":[0],"Precast":[1],"dry":[2,42],"connected":[3],"frame":[4,15,20],"systems":[5,16],"are":[6,17],"faster":[7],"to":[8,30,33],"construct":[9],"with":[10,44,74],"less":[11],"erection":[12],"efforts.":[13],"These":[14],"considered":[18],"non-emulate":[19],"systems.":[21],"The":[22,38,54,82,93,106,127],"lateral":[23],"load":[24],"behaviour":[25],"of":[26,40,84,141],"these":[27,41,142],"connections":[28,43],"needs":[29],"be":[31,101],"evaluated":[32,88],"ensure":[34],"the":[35,75,80,85,90,98,110],"desired":[36],"performance.":[37],"performance":[39,136],"embedded":[45],"bolts":[46],"proposed":[47],"was":[48,87],"studied":[49],"by":[50,60],"finite":[51],"elemental":[52],"analysis.":[53],"nonlinear":[55],"FEM":[56],"analysis":[57],"results":[58,77,107],"obtained":[59],"considering":[61],"appropriate":[62],"elements,":[63],"and":[64,70,121,138],"material":[65],"definition":[66],"parameters,":[67],"including":[68],"failure":[69,122],"interactions,":[71],"were":[72],"validated":[73],"experimental":[76],"available":[78],"in":[79],"literature.":[81],"rigidity":[83],"joints":[86,99,111,144],"using":[89],"beamline":[91,94],"method.":[92],"plot":[95],"unveils":[96],"that":[97,109],"can":[100],"classified":[102],"as":[103],"rigid":[104],"joints.":[105],"reveal":[108],"under":[112],"study":[113],"have":[114],"satisfactory":[115],"stiffness":[116],"degradation,":[117],"energy":[118],"dissipation":[119],"characteristics,":[120],"modes":[123],"like":[124],"monolithic":[125],"connection.":[126],"numerical":[128],"procedure":[129],"developed":[130],"provide":[131],"an":[132],"efficient":[133],"solution":[134],"for":[135],"evaluation":[137],"seismic":[139],"design":[140],"precast":[143]},"counts_by_year":[],"updated_date":"2026-10-08T09:06:37.294493","created_date":"2024-04-08T00:00:00"}
