{"id":"https://openalex.org/W4391928596","doi":"https://doi.org/10.5755/j01.sace.34.1.35512","title":"A Numerical Study of Methods to Improve Moisture Safety of Ventilated Wooden Roofs","display_name":"A Numerical Study of Methods to Improve Moisture Safety of Ventilated Wooden Roofs","publication_year":2024,"publication_date":"2024-02-19","ids":{"openalex":"https://openalex.org/W4391928596","doi":"https://doi.org/10.5755/j01.sace.34.1.35512"},"language":"en","primary_location":{"id":"doi:10.5755/j01.sace.34.1.35512","doi":"https://doi.org/10.5755/j01.sace.34.1.35512","is_oa":true,"landing_page_url":"http://dx.doi.org/10.5755/j01.sace.34.1.35512","pdf_url":"https://sace.ktu.lt/index.php/DAS/article/download/35512/16255","source":{"id":"https://openalex.org/S2764609074","display_name":"Journal of Sustainable Architecture and Civil Engineering","issn_l":"2029-9990","issn":["2029-9990","2335-2000"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","oarl","poland-20","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310317509","host_organization_name":"Kaunas University of Technology","host_organization_lineage":["https://openalex.org/P4310317509"],"host_organization_lineage_names":["Kaunas University of Technology"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Sustainable Architecture and Civil Engineering","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://sace.ktu.lt/index.php/DAS/article/download/35512/16255","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5062219827","display_name":"Klaus Viljanen","orcid":"https://orcid.org/0000-0002-6853-6165","observed_orcids":["https://orcid.org/0000-0002-6853-6165"]},"institutions":[{"id":"https://openalex.org/I9927081","display_name":"Aalto University","ror":"https://ror.org/020hwjq30","country_code":"FI","type":"education","lineage":["https://openalex.org/I9927081"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Klaus Viljanen","raw_affiliation_strings":["Aalto University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Aalto University","institution_ids":["https://openalex.org/I9927081"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072504584","display_name":"Laurina C Felius","orcid":"https://orcid.org/0000-0002-8680-9788","observed_orcids":["https://orcid.org/0000-0002-8680-9788"]},"institutions":[{"id":"https://openalex.org/I4210124441","display_name":"Ramboll (Norway)","ror":"https://ror.org/02w96wv37","country_code":"NO","type":"company","lineage":["https://openalex.org/I4210096927","https://openalex.org/I4210124441"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Laurina Felius","raw_affiliation_strings":["Ramb\u00f8ll Norge AS, Trondheim, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ramb\u00f8ll Norge AS, Trondheim, Norway","institution_ids":["https://openalex.org/I4210124441"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"34","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12105","display_name":"Hygrothermal properties of building materials","score":0.9613999724388123,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12105","display_name":"Hygrothermal properties of building materials","score":0.9613999724388123,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.0272000003606081,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.0038999998942017555,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/moisture-safety","display_name":"moisture safety","score":0.9589999914169312},{"id":"https://openalex.org/keywords/hygrothermal-performance","display_name":"hygrothermal performance","score":0.9319999814033508},{"id":"https://openalex.org/keywords/mold-growth","display_name":"mold growth","score":0.949999988079071},{"id":"https://openalex.org/keywords/nordic-climate","display_name":"Nordic climate","score":0.8709999918937683}],"concepts":[{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6486567854881287},{"id":"https://openalex.org/C176864760","wikidata":"https://www.wikidata.org/wiki/Q217651","display_name":"Moisture","level":2,"score":0.5031484961509705},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.4435281753540039},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4099823236465454},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.3952324390411377},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.3760991394519806},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.3750893175601959},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.15180110931396484},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.13171115517616272}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.5755/j01.sace.34.1.35512","doi":"https://doi.org/10.5755/j01.sace.34.1.35512","is_oa":true,"landing_page_url":"http://dx.doi.org/10.5755/j01.sace.34.1.35512","pdf_url":"https://sace.ktu.lt/index.php/DAS/article/download/35512/16255","source":{"id":"https://openalex.org/S2764609074","display_name":"Journal of Sustainable Architecture and Civil Engineering","issn_l":"2029-9990","issn":["2029-9990","2335-2000"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","oarl","poland-20","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310317509","host_organization_name":"Kaunas University of Technology","host_organization_lineage":["https://openalex.org/P4310317509"],"host_organization_lineage_names":["Kaunas University of Technology"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Sustainable Architecture and Civil Engineering","raw_type":"journal-article"},{"id":"pmh:oai:aaltodoc.aalto.fi:123456789/127241","doi":null,"is_oa":true,"landing_page_url":"https://research.aalto.fi/en/publications/e4aac345-3462-44d2-82f9-eb237e83f556","pdf_url":null,"source":{"id":"https://openalex.org/S4306401662","display_name":"Aaltodoc (Aalto University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I9927081","host_organization_name":"Aalto University","host_organization_lineage":["https://openalex.org/I9927081"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.5755/j01.sace.34.1.35512","doi":"https://doi.org/10.5755/j01.sace.34.1.35512","is_oa":true,"landing_page_url":"http://dx.doi.org/10.5755/j01.sace.34.1.35512","pdf_url":"https://sace.ktu.lt/index.php/DAS/article/download/35512/16255","source":{"id":"https://openalex.org/S2764609074","display_name":"Journal of Sustainable Architecture and Civil Engineering","issn_l":"2029-9990","issn":["2029-9990","2335-2000"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","oarl","poland-20","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310317509","host_organization_name":"Kaunas University of Technology","host_organization_lineage":["https://openalex.org/P4310317509"],"host_organization_lineage_names":["Kaunas University of Technology"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Sustainable Architecture and Civil Engineering","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.5351999998092651,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"},{"score":0.428600013256073,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4391928596.pdf","grobid_xml":"https://content.openalex.org/works/W4391928596.grobid-xml"},"referenced_works_count":13,"referenced_works":["https://openalex.org/W241788850","https://openalex.org/W281122320","https://openalex.org/W2041497894","https://openalex.org/W2068193977","https://openalex.org/W2761605671","https://openalex.org/W2993519412","https://openalex.org/W2995750610","https://openalex.org/W3000350992","https://openalex.org/W3040268885","https://openalex.org/W3134333276","https://openalex.org/W4280561380","https://openalex.org/W6910257975","https://openalex.org/W6991532226"],"related_works":["https://openalex.org/W4386124293","https://openalex.org/W3209826656","https://openalex.org/W4405382060","https://openalex.org/W4200388136","https://openalex.org/W4390829518","https://openalex.org/W2344903117","https://openalex.org/W2762869673","https://openalex.org/W2948622440","https://openalex.org/W3134966288","https://openalex.org/W2993519412"],"abstract_inverted_index":{"The":[0,62,82],"hygrothermal":[1],"performance":[2],"of":[3,34,50,67,76,84,93,104],"highly":[4],"insulated,":[5],"prefabricated":[6],"wooden":[7],"roof":[8,52,60,69,88,100],"structures":[9],"is":[10],"likely":[11],"to":[12,15,20,29],"deteriorate":[13],"due":[14],"the":[16,21,27,31,47,51,59,65,74,80,91],"low":[17],"heat":[18],"flux":[19],"ventilation":[22,48,70],"cavity.":[23],"This":[24],"article":[25],"evaluates":[26],"possibility":[28],"improve":[30],"moisture":[32],"safety":[33],"such":[35],"roofs":[36],"in":[37,79,98],"a":[38,99],"Nordic":[39],"climate":[40],"by":[41,54],"using":[42,55],"different":[43],"control":[44],"methods":[45],"for":[46],"rate":[49],"and":[53],"thermal":[56,85],"insulation":[57,86],"above":[58,87],"sheathing.":[61],"results":[63],"support":[64],"use":[66,83],"adaptive":[68],"as":[71],"it":[72],"decreases":[73,90],"probability":[75,92],"mould":[77,94],"growth":[78,95],"roof.":[81],"sheathing":[89],"only":[96],"slightly":[97],"with":[101],"elevated":[102],"amount":[103],"built-in":[105],"moisture.":[106]},"counts_by_year":[],"updated_date":"2026-09-07T09:17:50.787605","created_date":"2024-02-20T00:00:00"}
