{"id":"https://openalex.org/W4390695166","doi":"https://doi.org/10.1002/htj.22998","title":"Thermo\u2010hydraulic performance investigation of solar air heater duct having staggered D\u2010shaped ribs: Numerical approach","display_name":"Thermo\u2010hydraulic performance investigation of solar air heater duct having staggered D\u2010shaped ribs: Numerical approach","publication_year":2024,"publication_date":"2024-01-10","ids":{"openalex":"https://openalex.org/W4390695166","doi":"https://doi.org/10.1002/htj.22998"},"language":"en","primary_location":{"id":"doi:10.1002/htj.22998","doi":"https://doi.org/10.1002/htj.22998","is_oa":false,"landing_page_url":"https://doi.org/10.1002/htj.22998","pdf_url":null,"source":{"id":"https://openalex.org/S41149888","display_name":"Heat Transfer","issn_l":"2688-4534","issn":["2688-4534","2688-4542"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Heat Transfer","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5023959661","display_name":"Nitesh Dutt","orcid":"https://orcid.org/0000-0002-0405-3850","observed_orcids":["https://orcid.org/0000-0002-0405-3850"]},"institutions":[{"id":"https://openalex.org/I154851008","display_name":"Indian Institute of Technology Roorkee","ror":"https://ror.org/00582g326","country_code":"IN","type":"education","lineage":["https://openalex.org/I154851008"]},{"id":"https://openalex.org/I4405265151","display_name":"COER University","ror":"https://ror.org/040m46366","country_code":"IN","type":"education","lineage":["https://openalex.org/I4405265151"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Nitesh Dutt","raw_affiliation_strings":["Department of Mechanical Engineering, COER University, Roorkee, Uttarakhand, India"],"raw_orcid":"https://orcid.org/0000-0002-0405-3850","affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, COER University, Roorkee, Uttarakhand, India","institution_ids":["https://openalex.org/I154851008","https://openalex.org/I4405265151"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002233732","display_name":"Ankush Jageshwar Hedau","orcid":"https://orcid.org/0000-0003-0620-9895","observed_orcids":["https://orcid.org/0000-0003-0620-9895"]},"institutions":[{"id":"https://openalex.org/I154851008","display_name":"Indian Institute of Technology Roorkee","ror":"https://ror.org/00582g326","country_code":"IN","type":"education","lineage":["https://openalex.org/I154851008"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ankush Hedau","raw_affiliation_strings":["Department of Hydro and Renewable Energy, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India"],"raw_orcid":"https://orcid.org/0000-0003-0620-9895","affiliations":[{"raw_affiliation_string":"Department of Hydro and Renewable Energy, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India","institution_ids":["https://openalex.org/I154851008"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054037779","display_name":"Ashwani Kumar","orcid":"https://orcid.org/0000-0003-4099-935X","observed_orcids":["https://orcid.org/0000-0003-4099-935X","https://orcid.org/0000-0002-8071-5748"]},"institutions":[{"id":"https://openalex.org/I2801491316","display_name":"Government of Uttar Pradesh","ror":"https://ror.org/00hx1yw75","country_code":"IN","type":"government","lineage":["https://openalex.org/I2801491316"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ashwani Kumar","raw_affiliation_strings":["Technical Education Department Uttar Pradesh, Kanpur, India"],"raw_orcid":"https://orcid.org/0000-0003-4099-935X","affiliations":[{"raw_affiliation_string":"Technical Education Department Uttar Pradesh, Kanpur, India","institution_ids":["https://openalex.org/I2801491316"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002384477","display_name":"Mukesh Kumar Awasthi","orcid":"https://orcid.org/0000-0002-6706-5226","observed_orcids":["https://orcid.org/0000-0002-6706-5226"]},"institutions":[{"id":"https://openalex.org/I143247161","display_name":"Babasaheb Bhimrao Ambedkar University","ror":"https://ror.org/04x7ccp17","country_code":"IN","type":"education","lineage":["https://openalex.org/I143247161"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Mukesh Kumar Awasthi","raw_affiliation_strings":["Department of Mathematics, Babasaheb Bhimrao Ambedkar University, Lucknow, Uttar Pradesh, India"],"raw_orcid":"https://orcid.org/0000-0002-6706-5226","affiliations":[{"raw_affiliation_string":"Department of Mathematics, Babasaheb Bhimrao Ambedkar University, Lucknow, Uttar Pradesh, India","institution_ids":["https://openalex.org/I143247161"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5093670902","display_name":"Sachin Hedau","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405278111","display_name":"Priyadarshini College of Engineering","ror":"https://ror.org/050zc5n91","country_code":"IN","type":"education","lineage":["https://openalex.org/I4405278111"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sachin Hedau","raw_affiliation_strings":["Department of Mechanical Engineering, Priyadarshini College of Engineering, Nagpur, Maharashtra, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Priyadarshini College of Engineering, Nagpur, Maharashtra, India","institution_ids":["https://openalex.org/I4405278111"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5036747968","display_name":"Chandan Swaroop Meena","orcid":"https://orcid.org/0000-0002-3274-6275","observed_orcids":["https://orcid.org/0000-0002-3274-6275"]},"institutions":[{"id":"https://openalex.org/I2801347850","display_name":"Central Building Research Institute","ror":"https://ror.org/03gjr0792","country_code":"IN","type":"facility","lineage":["https://openalex.org/I2799351866","https://openalex.org/I2801347850","https://openalex.org/I4210134808","https://openalex.org/I66760702"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Chandan Swaroop Meena","raw_affiliation_strings":["Building Energy Efficiency Department, Central Building Research Institute, Roorkee, Uttarakhand, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Building Energy Efficiency Department, Central Building Research Institute, Roorkee, Uttarakhand, India","institution_ids":["https://openalex.org/I2801347850"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5002384477"],"corresponding_institution_ids":["https://openalex.org/I143247161"],"apc_list":{"value":2760,"currency":"USD","value_usd":2760},"apc_paid":null,"fwci":1.7821,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.81960131,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":99},"biblio":{"volume":"53","issue":"3","first_page":"1501","last_page":"1531"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10360","display_name":"Fluid Dynamics and Turbulent Flows","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/solar-air-heater","display_name":"solar air heater","score":0.9399999976158142},{"id":"https://openalex.org/keywords/duct-flow","display_name":"duct flow","score":0.6299999952316284},{"id":"https://openalex.org/keywords/thermal-hydraulic-performance","display_name":"thermal-hydraulic performance","score":0.8519999980926514},{"id":"https://openalex.org/keywords/nusselt-number-enhancement","display_name":"Nusselt number enhancement","score":0.968999981880188},{"id":"https://openalex.org/keywords/friction-factor","display_name":"friction factor","score":0.9869999885559082},{"id":"https://openalex.org/keywords/3d-simulation","display_name":"three-dimensional simulation","score":0.6050000190734863}],"concepts":[{"id":"https://openalex.org/C130230704","wikidata":"https://www.wikidata.org/wiki/Q898280","display_name":"Nusselt number","level":4,"score":0.9307998418807983},{"id":"https://openalex.org/C182748727","wikidata":"https://www.wikidata.org/wiki/Q178932","display_name":"Reynolds number","level":3,"score":0.6525623798370361},{"id":"https://openalex.org/C178635117","wikidata":"https://www.wikidata.org/wiki/Q747499","display_name":"RADIUS","level":2,"score":0.5604904294013977},{"id":"https://openalex.org/C2986887940","wikidata":"https://www.wikidata.org/wiki/Q5503426","display_name":"Friction factor","level":4,"score":0.5368524193763733},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5194692015647888},{"id":"https://openalex.org/C2781212128","wikidata":"https://www.wikidata.org/wiki/Q2256181","display_name":"Duct (anatomy)","level":2,"score":0.49988293647766113},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.4638400673866272},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.45675501227378845},{"id":"https://openalex.org/C16644385","wikidata":"https://www.wikidata.org/wiki/Q1327735","display_name":"Hydraulic diameter","level":4,"score":0.44597697257995605},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.36796069145202637},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.36273109912872314},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3051903247833252},{"id":"https://openalex.org/C196558001","wikidata":"https://www.wikidata.org/wiki/Q190132","display_name":"Turbulence","level":2,"score":0.22083988785743713},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.08518722653388977},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1002/htj.22998","doi":"https://doi.org/10.1002/htj.22998","is_oa":false,"landing_page_url":"https://doi.org/10.1002/htj.22998","pdf_url":null,"source":{"id":"https://openalex.org/S41149888","display_name":"Heat Transfer","issn_l":"2688-4534","issn":["2688-4534","2688-4542"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Heat Transfer","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.878000020980835,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":46,"referenced_works":["https://openalex.org/W1975361659","https://openalex.org/W1977834662","https://openalex.org/W2000777194","https://openalex.org/W2007260745","https://openalex.org/W2009533294","https://openalex.org/W2021869818","https://openalex.org/W2061965252","https://openalex.org/W2062700810","https://openalex.org/W2087703984","https://openalex.org/W2088321266","https://openalex.org/W2121500667","https://openalex.org/W2160322555","https://openalex.org/W2278917893","https://openalex.org/W2399331689","https://openalex.org/W2508596589","https://openalex.org/W2555080439","https://openalex.org/W2598226475","https://openalex.org/W2801931076","https://openalex.org/W2899980014","https://openalex.org/W2951835132","https://openalex.org/W2964410128","https://openalex.org/W2986779116","https://openalex.org/W2990435859","https://openalex.org/W2994981938","https://openalex.org/W3014513895","https://openalex.org/W3040919794","https://openalex.org/W3047656466","https://openalex.org/W3082724972","https://openalex.org/W3138108350","https://openalex.org/W3153152372","https://openalex.org/W3157578946","https://openalex.org/W3165298349","https://openalex.org/W3173411197","https://openalex.org/W3193330873","https://openalex.org/W3203821211","https://openalex.org/W3208310360","https://openalex.org/W3209742152","https://openalex.org/W4206493521","https://openalex.org/W4220746374","https://openalex.org/W4220902405","https://openalex.org/W4230728729","https://openalex.org/W4248575332","https://openalex.org/W4297536358","https://openalex.org/W4320006149","https://openalex.org/W4362579716","https://openalex.org/W4383198860"],"related_works":["https://openalex.org/W4383198860","https://openalex.org/W4410378429","https://openalex.org/W7125578720","https://openalex.org/W4319590576","https://openalex.org/W7170169887","https://openalex.org/W2921565450","https://openalex.org/W2786635006","https://openalex.org/W4405166338","https://openalex.org/W2028364963","https://openalex.org/W2751847870"],"abstract_inverted_index":{"Abstract":[0],"The":[1,28,70,161],"thermohydraulic":[2],"performance":[3],"(THP)":[4],"of":[5,36,38,45,52,56,62,82,105,117,136,164,178,196,204],"a":[6,202],"solar":[7],"air":[8],"heater":[9],"(SAH)":[10],"duct":[11],"with":[12,201],"staggered":[13],"D\u2010shaped":[14],"ribs":[15],"as":[16,85,89,108,112,138,141,145],"roughness":[17,34],"geometry":[18],"is":[19,30,75,98,127,159,168],"examined":[20],"in":[21,123,150,194],"this":[22,156],"work":[23],"using":[24],"three\u2010dimensional":[25],"numerical":[26],"investigation.":[27],"investigation":[29],"carried":[31],"out":[32],"at":[33,80,103,132,155,173],"parameters":[35,118],"radius":[37,51],"rib":[39,53],"to":[40,50,68,77,100,129,170],"transverse":[41],"pitch":[42,49],"(r/Ptv)":[43],"ratios":[44,55],"0.1\u20130.35":[46],"and":[47,87,110,143,190,199,206],"longitudinal":[48],"(Plg/r)":[54],"4\u201310":[57],"under":[58],"varied":[59],"operating":[60],"circumstances":[61],"Reynolds":[63],"number":[64,73,125,188],"(Re)":[65],"from":[66],"10,200":[67],"20,200.":[69],"maximum":[71,94,121,162],"Nusselt":[72,124,187],"(Nu)":[74,189],"obtained":[76,99],"be":[78,101,130,171],"81.3":[79],"Re":[81,104,144,200],"20,200,":[83],"r/Ptv":[84,107,137],"0.1,":[86,139],"Plg/r":[88,111,140],"4.":[90,113],"In":[91,114,180],"contrast,":[92],"the":[93,115,120,148,151,165,174],"friction":[95,152,191],"factor":[96,153,192],"(f)":[97,193],"0.0169":[102],"10,200,":[106],"0.35,":[109],"range":[116,177],"examined,":[119],"enhancement":[122,149],"(Nu/Nus)":[126],"observed":[128],"1.35":[131],"an":[133],"optimal":[134],"parameter":[135,158,167],"4,":[142],"10,200.":[146],"Correspondingly,":[147],"(f/fs)":[154],"optimum":[157,176],"1.87.":[160],"value":[163],"THP":[166],"found":[169],"1.1":[172],"same":[175],"parameters.":[179],"further":[181],"analysis,":[182],"correlations":[183],"were":[184],"developed":[185],"for":[186],"terms":[195],"r/Ptv,":[197],"Plg/r,":[198],"deviation":[203],"\u00b12%":[205],"\u00b11.5%,":[207],"respectively.":[208]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":10}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2024-01-13T00:00:00"}
