{"id":"https://openalex.org/W4390035035","doi":"https://doi.org/10.1109/tr.2023.3336359","title":"Flow-Network-Based Method for the Reliability Analysis of Decentralized Power System Topologies With a Sequential Monte-Carlo Simulation","display_name":"Flow-Network-Based Method for the Reliability Analysis of Decentralized Power System Topologies With a Sequential Monte-Carlo Simulation","publication_year":2023,"publication_date":"2023-12-20","ids":{"openalex":"https://openalex.org/W4390035035","doi":"https://doi.org/10.1109/tr.2023.3336359"},"language":"en","primary_location":{"id":"doi:10.1109/tr.2023.3336359","doi":"https://doi.org/10.1109/tr.2023.3336359","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tr.2023.3336359","pdf_url":"https://ieeexplore.ieee.org/ielx7/24/4378406/10366515.pdf","source":{"id":"https://openalex.org/S87725633","display_name":"IEEE Transactions on Reliability","issn_l":"0018-9529","issn":["0018-9529","1558-1721"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","ccf-c","cwts-core","dongbi-b","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Reliability","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://ieeexplore.ieee.org/ielx7/24/4378406/10366515.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5074417486","display_name":"Matheus Montanini Breve","orcid":"https://orcid.org/0000-0003-0599-3892","observed_orcids":["https://orcid.org/0000-0003-0599-3892"]},"institutions":[{"id":"https://openalex.org/I889804353","display_name":"Robert Bosch (Germany)","ror":"https://ror.org/01fe0jt45","country_code":"DE","type":"company","lineage":["https://openalex.org/I889804353"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Matheus Montanini Breve","raw_affiliation_strings":["Department of Corporate Research at Robert Bosch GmbH, Renningen, Germany"],"raw_orcid":"https://orcid.org/0000-0003-0599-3892","affiliations":[{"raw_affiliation_string":"Department of Corporate Research at Robert Bosch GmbH, Renningen, Germany","institution_ids":["https://openalex.org/I889804353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019186692","display_name":"Bernd Bohnet","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I889804353","display_name":"Robert Bosch (Germany)","ror":"https://ror.org/01fe0jt45","country_code":"DE","type":"company","lineage":["https://openalex.org/I889804353"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Bernd Bohnet","raw_affiliation_strings":["Department of Corporate Research at Robert Bosch GmbH, Renningen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Corporate Research at Robert Bosch GmbH, Renningen, Germany","institution_ids":["https://openalex.org/I889804353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048439349","display_name":"Gabriele Michalke","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I889804353","display_name":"Robert Bosch (Germany)","ror":"https://ror.org/01fe0jt45","country_code":"DE","type":"company","lineage":["https://openalex.org/I889804353"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Gabriele Michalke","raw_affiliation_strings":["Department of Corporate Research at Robert Bosch GmbH, Renningen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Corporate Research at Robert Bosch GmbH, Renningen, Germany","institution_ids":["https://openalex.org/I889804353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043129551","display_name":"Julia Kowal","orcid":"https://orcid.org/0000-0002-8802-6365","observed_orcids":["https://orcid.org/0000-0002-8802-6365"]},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Julia Kowal","raw_affiliation_strings":["Institute of Energy and Automation Technology, Technical University of Berlin, Berlin, Germany"],"raw_orcid":"https://orcid.org/0000-0002-8802-6365","affiliations":[{"raw_affiliation_string":"Institute of Energy and Automation Technology, Technical University of Berlin, Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5063738226","display_name":"Kai Strunz","orcid":"https://orcid.org/0000-0002-2043-4549","observed_orcids":["https://orcid.org/0000-0002-2043-4549"]},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Kai Strunz","raw_affiliation_strings":["Institute of Energy and Automation Technology, Technical University of Berlin, Berlin, Germany"],"raw_orcid":"https://orcid.org/0000-0002-2043-4549","affiliations":[{"raw_affiliation_string":"Institute of Energy and Automation Technology, Technical University of Berlin, Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2345,"currency":"USD","value_usd":2345},"apc_paid":{"value":2345,"currency":"USD","value_usd":2345},"fwci":1.4039,"has_fulltext":true,"cited_by_count":9,"citation_normalized_percentile":{"value":0.80228897,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":98},"biblio":{"volume":"73","issue":"2","first_page":"1005","last_page":"1019"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/decentralized-power-systems","display_name":"decentralized power systems","score":0.9599999785423279},{"id":"https://openalex.org/keywords/power-system-reliability","display_name":"power system reliability","score":0.7760000228881836},{"id":"https://openalex.org/keywords/availability-analysis","display_name":"availability analysis","score":0.4699999988079071},{"id":"https://openalex.org/keywords/flow-networks","display_name":"flow networks","score":0.9789999723434448},{"id":"https://openalex.org/keywords/sequential-monte-carlo-simulation","display_name":"sequential Monte Carlo simulation","score":0.9179999828338623},{"id":"https://openalex.org/keywords/energy-storage-systems","display_name":"energy storage systems","score":0.7490000128746033},{"id":"https://openalex.org/keywords/system-design-comparison","display_name":"system design comparison","score":0.5230000019073486}],"concepts":[{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.7941088080406189},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.7878081202507019},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6486448049545288},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6021972894668579},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5357263684272766},{"id":"https://openalex.org/C201729545","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability theory","level":3,"score":0.4676014482975006},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.41606706380844116},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.40888747572898865},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.39505261182785034},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3254709243774414},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22649028897285461},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1600048840045929},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.15321007370948792},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10885840654373169},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.10368779301643372},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10003381967544556},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tr.2023.3336359","doi":"https://doi.org/10.1109/tr.2023.3336359","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tr.2023.3336359","pdf_url":"https://ieeexplore.ieee.org/ielx7/24/4378406/10366515.pdf","source":{"id":"https://openalex.org/S87725633","display_name":"IEEE Transactions on Reliability","issn_l":"0018-9529","issn":["0018-9529","1558-1721"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","ccf-c","cwts-core","dongbi-b","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Reliability","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1109/tr.2023.3336359","doi":"https://doi.org/10.1109/tr.2023.3336359","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tr.2023.3336359","pdf_url":"https://ieeexplore.ieee.org/ielx7/24/4378406/10366515.pdf","source":{"id":"https://openalex.org/S87725633","display_name":"IEEE Transactions on Reliability","issn_l":"0018-9529","issn":["0018-9529","1558-1721"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","ccf-c","cwts-core","dongbi-b","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Reliability","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9"},{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4390035035.pdf","grobid_xml":"https://content.openalex.org/works/W4390035035.grobid-xml"},"referenced_works_count":66,"referenced_works":["https://openalex.org/W72942802","https://openalex.org/W109353830","https://openalex.org/W1447980612","https://openalex.org/W1968686485","https://openalex.org/W1978353289","https://openalex.org/W1981149018","https://openalex.org/W1989512626","https://openalex.org/W1996824380","https://openalex.org/W2001104504","https://openalex.org/W2001653692","https://openalex.org/W2019780681","https://openalex.org/W2038872716","https://openalex.org/W2061948033","https://openalex.org/W2067534408","https://openalex.org/W2068459310","https://openalex.org/W2080267935","https://openalex.org/W2082183509","https://openalex.org/W2089758604","https://openalex.org/W2093590287","https://openalex.org/W2096831158","https://openalex.org/W2105697967","https://openalex.org/W2108240852","https://openalex.org/W2113146118","https://openalex.org/W2115826669","https://openalex.org/W2116804326","https://openalex.org/W2118680159","https://openalex.org/W2132022337","https://openalex.org/W2134858346","https://openalex.org/W2136174945","https://openalex.org/W2137906884","https://openalex.org/W2140973599","https://openalex.org/W2141824346","https://openalex.org/W2143474390","https://openalex.org/W2143676145","https://openalex.org/W2148233873","https://openalex.org/W2154884120","https://openalex.org/W2155556726","https://openalex.org/W2164349659","https://openalex.org/W2237076304","https://openalex.org/W2289217407","https://openalex.org/W2342249984","https://openalex.org/W2342511043","https://openalex.org/W2381162371","https://openalex.org/W2410001329","https://openalex.org/W2431750875","https://openalex.org/W2626683420","https://openalex.org/W2740893394","https://openalex.org/W2752734004","https://openalex.org/W2770842518","https://openalex.org/W2970042309","https://openalex.org/W3000480649","https://openalex.org/W3011140869","https://openalex.org/W3025078293","https://openalex.org/W3036168605","https://openalex.org/W3122883208","https://openalex.org/W3136244857","https://openalex.org/W3160771821","https://openalex.org/W3163523342","https://openalex.org/W3177083901","https://openalex.org/W3200509025","https://openalex.org/W4213060235","https://openalex.org/W4237971090","https://openalex.org/W4244424643","https://openalex.org/W4310071148","https://openalex.org/W4318407365","https://openalex.org/W4385708546"],"related_works":["https://openalex.org/W2137906884","https://openalex.org/W4285817324","https://openalex.org/W2380807368","https://openalex.org/W2987356942","https://openalex.org/W2358668470","https://openalex.org/W4416996675","https://openalex.org/W2045230251","https://openalex.org/W2898409730","https://openalex.org/W3143131995","https://openalex.org/W6997236926"],"abstract_inverted_index":{"This":[0],"article":[1],"introduces":[2],"a":[3,33,48,95,144],"sequential":[4],"Monte-Carlo":[5],"simulation":[6,128],"method":[7,42,141],"(MCS)":[8],"based":[9,153],"on":[10,154],"flow":[11],"networks":[12],"to":[13,31,46,60,104,172],"represent":[14],"decentralized":[15,53],"power":[16,55,81,102],"systems":[17,66,167],"and":[18,22,64,70,84,151,158,170],"evaluate":[19],"the":[20,37,101,105,109,112,116,122,155,159,174],"reliability":[21,152],"availability":[23,150],"of":[24,50,52,74,89,111,133,146,161],"their":[25],"topologies.":[26],"It":[27,57],"can":[28,43,77,129,142],"be":[29,44,78],"used":[30],"provide":[32],"comparison":[34],"basis":[35],"during":[36],"system":[38,90,106,113,123,136,149,156],"design":[39],"phase.":[40],"The":[41,87,127,140],"employed":[45],"simulate":[47,61],"variety":[49,145],"types":[51],"local":[54],"systems.":[56],"is":[58,92,124],"able":[59],"bidirectional,":[62],"radial,":[63],"meshed":[65],"with":[67],"both":[68],"repairable":[69],"nonrepairable":[71],"elements.":[72],"Examples":[73],"elements":[75],"that":[76,99],"simulated":[79,171],"include":[80],"sources,":[82],"loads,":[83],"energy-storage":[85],"units.":[86],"determination":[88],"success":[91,137],"performed":[93],"using":[94],"minimum-cost-maximum-flow":[96],"graph":[97],"algorithm":[98],"calculates":[100],"delivered":[103],"loads":[107,117],"given":[108],"state":[110],"components.":[114,164],"If":[115],"are":[118,168],"being":[119],"properly":[120],"supplied,":[121],"deemed":[125],"functional.":[126],"accommodate":[130],"additional":[131],"sets":[132],"rules":[134],"for":[135,148],"if":[138],"needed.":[139],"generate":[143],"indices":[147],"topology":[157],"parameters":[160],"its":[162],"individual":[163],"Three":[165],"example":[166],"presented":[169],"showcase":[173],"method's":[175],"capabilities.":[176]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":2}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2023-12-21T00:00:00"}
