{"id":"https://openalex.org/W4389985243","doi":"https://doi.org/10.1615/ihtc17.490-100","title":"FLOW BOILING IN A MICROGAP AND MICRO MULTI-CHANNEL HEAT EXCHANGER","display_name":"FLOW BOILING IN A MICROGAP AND MICRO MULTI-CHANNEL HEAT EXCHANGER","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4389985243","doi":"https://doi.org/10.1615/ihtc17.490-100"},"language":"en","primary_location":{"id":"doi:10.1615/ihtc17.490-100","doi":"https://doi.org/10.1615/ihtc17.490-100","is_oa":false,"landing_page_url":"https://doi.org/10.1615/ihtc17.490-100","pdf_url":null,"source":{"id":"https://openalex.org/S4306523287","display_name":"International Heat Transfer Conference (IHTC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceeding of International Heat Transfer Conference 17","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W4389985243"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5025369946","display_name":"Ali H. Al-Zaidi","orcid":"https://orcid.org/0000-0003-0882-0655","observed_orcids":["https://orcid.org/0000-0003-0882-0655"]},"institutions":[{"id":"https://openalex.org/I35906937","display_name":"University of Misan","ror":"https://ror.org/05b5sds65","country_code":"IQ","type":"education","lineage":["https://openalex.org/I35906937"]},{"id":"https://openalex.org/I59433898","display_name":"Brunel University of London","ror":"https://ror.org/00dn4t376","country_code":"GB","type":"education","lineage":["https://openalex.org/I124357947","https://openalex.org/I59433898"]}],"countries":["GB","IQ"],"is_corresponding":false,"raw_author_name":"Ali H. Al-Zaidi","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge,\nUB8 3PH, UK; University of Misan, Al-Amarah, 62001, Iraq","Department of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge,\nUB8 3PH, UK","University of Misan, Al-Amarah, 62001, Iraq"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge,\nUB8 3PH, UK; University of Misan, Al-Amarah, 62001, Iraq","institution_ids":["https://openalex.org/I35906937","https://openalex.org/I59433898"]},{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge,\nUB8 3PH, UK","institution_ids":["https://openalex.org/I59433898"]},{"raw_affiliation_string":"University of Misan, Al-Amarah, 62001, Iraq","institution_ids":["https://openalex.org/I35906937"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041184771","display_name":"Mohamed M. Mahmoud","orcid":"https://orcid.org/0000-0003-4381-6424","observed_orcids":["https://orcid.org/0000-0003-4381-6424"]},"institutions":[{"id":"https://openalex.org/I192398990","display_name":"Zagazig University","ror":"https://ror.org/053g6we49","country_code":"EG","type":"education","lineage":["https://openalex.org/I192398990"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Mohamed M. Mahmoud","raw_affiliation_strings":["Faculty of Engineering, Zagazig University, Zagazig, 44519, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Engineering, Zagazig University, Zagazig, 44519, Egypt","institution_ids":["https://openalex.org/I192398990"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025229173","display_name":"Atanas Ivanov","orcid":"https://orcid.org/0000-0001-9293-2611","observed_orcids":["https://orcid.org/0000-0001-9293-2611"]},"institutions":[{"id":"https://openalex.org/I59433898","display_name":"Brunel University of London","ror":"https://ror.org/00dn4t376","country_code":"GB","type":"education","lineage":["https://openalex.org/I124357947","https://openalex.org/I59433898"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Atanas Ivanov","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge,\nUB8 3PH, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge,\nUB8 3PH, UK","institution_ids":["https://openalex.org/I59433898"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079027302","display_name":"Tassos G. Karayiannis","orcid":"https://orcid.org/0000-0002-5225-960X","observed_orcids":["https://orcid.org/0000-0002-5225-960X"]},"institutions":[{"id":"https://openalex.org/I59433898","display_name":"Brunel University of London","ror":"https://ror.org/00dn4t376","country_code":"GB","type":"education","lineage":["https://openalex.org/I124357947","https://openalex.org/I59433898"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Tassos G. Karayiannis","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering Brunel University London, Uxbridge, UP8 3PH, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering Brunel University London, Uxbridge, UP8 3PH, UK","institution_ids":["https://openalex.org/I59433898"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"9","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10850","display_name":"Heat Transfer and Boiling Studies","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10850","display_name":"Heat Transfer and Boiling Studies","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12567","display_name":"Heat transfer and supercritical fluids","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flow-boiling","display_name":"flow boiling","score":0.949999988079071},{"id":"https://openalex.org/keywords/micro-heat-exchangers","display_name":"micro heat exchangers","score":0.7459999918937683},{"id":"https://openalex.org/keywords/two-phase-flow","display_name":"two-phase flow","score":0.8790000081062317},{"id":"https://openalex.org/keywords/flow-patterns","display_name":"flow patterns","score":0.7020000219345093},{"id":"https://openalex.org/keywords/heat-transfer-coefficient","display_name":"heat transfer coefficient","score":0.8410000205039978},{"id":"https://openalex.org/keywords/pressure-drop","display_name":"pressure drop","score":0.9980000257492065},{"id":"https://openalex.org/keywords/hfe-7100","display_name":"HFE-7100","score":0.8270000219345093},{"id":"https://openalex.org/keywords/high-heat-flux-cooling","display_name":"high heat flux cooling","score":0.7549999952316284},{"id":"https://openalex.org/keywords/performance-index","display_name":"performance index","score":0.6700000166893005},{"id":"https://openalex.org/keywords/flow-visualization","display_name":"flow visualization","score":0.574999988079071}],"concepts":[{"id":"https://openalex.org/C157777378","wikidata":"https://www.wikidata.org/wiki/Q41716","display_name":"Boiling","level":2,"score":0.6723098754882812},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.6003382205963135},{"id":"https://openalex.org/C2984797202","wikidata":"https://www.wikidata.org/wiki/Q3523888","display_name":"Flow boiling","level":5,"score":0.5264790058135986},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.5248948335647583},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.5063215494155884},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.34369659423828125},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33913713693618774},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.321757972240448},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.30114686489105225},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.25452613830566406},{"id":"https://openalex.org/C197194406","wikidata":"https://www.wikidata.org/wiki/Q7068214","display_name":"Nucleate boiling","level":4,"score":0.2134559452533722},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.20616841316223145},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15407320857048035},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.13967588543891907},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.08133390545845032},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08037114143371582}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1615/ihtc17.490-100","doi":"https://doi.org/10.1615/ihtc17.490-100","is_oa":false,"landing_page_url":"https://doi.org/10.1615/ihtc17.490-100","pdf_url":null,"source":{"id":"https://openalex.org/S4306523287","display_name":"International Heat Transfer Conference (IHTC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceeding of International Heat Transfer Conference 17","raw_type":"proceedings-article"},{"id":"pmh:oai:bura.brunel.ac.uk:2438/26578","doi":null,"is_oa":false,"landing_page_url":"https://bura.brunel.ac.uk/handle/2438/26578","pdf_url":null,"source":{"id":"https://openalex.org/S4306401473","display_name":"Brunel University Research Archive (BURA) (Brunel University London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I59433898","host_organization_name":"Brunel University of London","host_organization_lineage":["https://openalex.org/I59433898"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"17th International Heat Transfer Conference 2023","raw_type":"Conference paper"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1964026143","https://openalex.org/W1976590097","https://openalex.org/W1990910963","https://openalex.org/W2080921376","https://openalex.org/W2089984638","https://openalex.org/W2509117982","https://openalex.org/W2790625566","https://openalex.org/W2910842695","https://openalex.org/W2917865290","https://openalex.org/W2953579577","https://openalex.org/W3006518675","https://openalex.org/W3093603036","https://openalex.org/W3093741305","https://openalex.org/W3112369643","https://openalex.org/W3124133521","https://openalex.org/W4230346472","https://openalex.org/W4247060813","https://openalex.org/W4282597127"],"related_works":["https://openalex.org/W2330038734","https://openalex.org/W2904677246","https://openalex.org/W4389985911","https://openalex.org/W4389985751","https://openalex.org/W4251562194","https://openalex.org/W6903746178","https://openalex.org/W1947500880","https://openalex.org/W4389985922","https://openalex.org/W2946739083","https://openalex.org/W3207693077"],"abstract_inverted_index":{"Two-phase":[0],"flow":[1,32,209],"in":[2,48,103,142],"micro":[3,56,110],"scale":[4],"heat":[5,18,25,37,60,112,147,177,211,233],"exchangers":[6],"is":[7],"considered":[8],"a":[9,52,55,68,88,130,193,204],"promising":[10],"cooling":[11],"technique":[12],"for":[13,175,217,246],"electronic":[14],"and":[15,24,36,54,82,100,106,139,195,214,223,244],"other":[16],"high":[17,69],"flux":[19,148,158],"devices.":[20],"Different":[21],"operating":[22],"conditions":[23],"exchanger":[26],"geometries":[27,220],"can":[28],"lead":[29],"to":[30,152,162,236],"different":[31,44],"patterns,":[33,210],"pressure":[34,215,239],"drop":[35,216],"transfer":[38,212,234],"characteristics.":[39],"The":[40,73,109,145,166,179,187,208,225],"performance":[41,226],"of":[42,91,231],"two":[43,219,248],"designs":[45],"was":[46,75,169,191,200,241],"examined":[47,249],"this":[49],"study,":[50],"namely:":[51],"microgap":[53,74],"multi-channel":[57,111],"configuration.":[58],"Both":[59],"sinks":[61],"were":[62,181,221],"manufactured":[63],"from":[64,150,160],"oxygen-free":[65],"copper":[66],"using":[67,203],"precision":[70],"micro-milling":[71],"machine.":[72],"1":[76],"mm":[77,80,84,123,126,133],"high,":[78,124],"20":[79,92],"wide":[81,127],"25":[83,94],"long,":[85],"i.e.":[86,228],"had":[87,114],"base":[89,117,146],"area":[90],"\u00d7":[93],"mm2,":[95],"with":[96,119,135],"the":[97,104,115,136,143,156,218,229,232,237,247],"fluid":[98,137,189],"entering":[99,138],"exiting":[101,140],"vertically":[102,141],"inlet":[105,167],"outlet":[107],"plenum.":[108],"sink":[113],"same":[116],"area,":[118],"40":[120],"channels,":[121],"0.7":[122],"0.35":[125],"separated":[128],"by":[129],"wall":[131],"0.15":[132],"thick,":[134],"plena.":[144],"ranged":[149],"34":[151],"440":[153],"kW/m2,":[154],"while":[155],"mass":[157],"varied":[159],"100":[161],"200":[163],"kg/m2":[164],"s.":[165],"sub-cooling":[168],"kept":[170],"low,":[171],"at":[172,183],"5":[173],"K":[174],"both":[176],"sinks.":[178],"experiments":[180],"performed":[182],"atmospheric":[184],"system":[185],"pressure.":[186],"working":[188],"used":[190],"HFE-7100,":[192],"dielectric":[194],"eco-friendly":[196],"refrigerant.":[197],"Flow":[198],"visualization":[199],"carried":[201],"out":[202],"high-speed,":[205],"high-resolution":[206],"camera.":[207],"coefficient":[213],"obtained":[222],"compared.":[224],"index,":[227],"ratio":[230],"rate":[235],"total":[238],"drop,":[240],"also":[242],"calculated":[243],"compared":[245],"geometries.":[250]},"counts_by_year":[],"updated_date":"2026-11-13T13:42:25.865203","created_date":"2023-12-21T00:00:00"}
