{"id":"https://openalex.org/W4387982729","doi":"https://doi.org/10.1109/ccpis59145.2023.10291846","title":"Asymmetrical Fault Analysis Using P2P Coordinated Control System for DFIG-STATCOM","display_name":"Asymmetrical Fault Analysis Using P2P Coordinated Control System for DFIG-STATCOM","publication_year":2023,"publication_date":"2023-09-01","ids":{"openalex":"https://openalex.org/W4387982729","doi":"https://doi.org/10.1109/ccpis59145.2023.10291846"},"language":"en","primary_location":{"id":"doi:10.1109/ccpis59145.2023.10291846","doi":"https://doi.org/10.1109/ccpis59145.2023.10291846","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccpis59145.2023.10291846","pdf_url":null,"source":{"id":"https://openalex.org/S7407086284","display_name":"International Conference on Circuits, Power and Intelligent Systems (CCPIS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 1st International Conference on Circuits, Power and Intelligent Systems (CCPIS)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5087675068","display_name":"Manish Bharat","orcid":"https://orcid.org/0000-0003-4943-9623","observed_orcids":["https://orcid.org/0000-0003-4943-9623"]},"institutions":[{"id":"https://openalex.org/I83737708","display_name":"REVA University","ror":"https://ror.org/03gtcxd54","country_code":"IN","type":"education","lineage":["https://openalex.org/I83737708"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Manish Bharat","raw_affiliation_strings":["School of EEE REVA University, Bengaluru, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of EEE REVA University, Bengaluru, India","institution_ids":["https://openalex.org/I83737708"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026029952","display_name":"Swapna Ch","orcid":"https://orcid.org/0000-0001-5991-4526","observed_orcids":["https://orcid.org/0000-0001-5991-4526"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Swapna Ch","raw_affiliation_strings":["Sri Venkateshwara College of Engineering,Dept. of Electronics and communication,Bengaluru,India","Dept. of Electronics and communication, Sri Venkateshwara College of Engineering, Bengaluru, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sri Venkateshwara College of Engineering,Dept. of Electronics and communication,Bengaluru,India","institution_ids":[]},{"raw_affiliation_string":"Dept. of Electronics and communication, Sri Venkateshwara College of Engineering, Bengaluru, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044568199","display_name":"Ritesh Kumar Dash","orcid":"https://orcid.org/0000-0001-8731-603X","observed_orcids":["https://orcid.org/0000-0001-8731-603X"]},"institutions":[{"id":"https://openalex.org/I83737708","display_name":"REVA University","ror":"https://ror.org/03gtcxd54","country_code":"IN","type":"education","lineage":["https://openalex.org/I83737708"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ritesh Dash","raw_affiliation_strings":["School of EEE REVA University, Bengaluru, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of EEE REVA University, Bengaluru, India","institution_ids":["https://openalex.org/I83737708"]}]},{"author_position":"last","author":{"id":null,"display_name":"Durga Madhab Swain","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Durga Madhab Swain","raw_affiliation_strings":["ABIT,Dept. of Electrical Engineering,Cuttack,India","Dept. of Electrical Engineering, ABIT, Cuttack, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ABIT,Dept. of Electrical Engineering,Cuttack,India","institution_ids":[]},{"raw_affiliation_string":"Dept. of Electrical Engineering, ABIT, Cuttack, India","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7418,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.61802348,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.8877000212669373,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.8877000212669373,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.08990000188350677,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.013700000010430813,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/doubly-fed-induction-generator","display_name":"doubly fed induction generator","score":0.8489999771118164},{"id":"https://openalex.org/keywords/statcom","display_name":"STATCOM","score":0.8489999771118164},{"id":"https://openalex.org/keywords/distributed-control","display_name":"distributed control","score":0.9739999771118164},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.9330000281333923},{"id":"https://openalex.org/keywords/fault-location-identification","display_name":"fault location estimation","score":0.9929999709129333},{"id":"https://openalex.org/keywords/fault-mitigation","display_name":"fault mitigation","score":0.6930000185966492},{"id":"https://openalex.org/keywords/wind-power-integration","display_name":"wind power integration","score":0.5170000195503235},{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":0.699999988079071}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7447783350944519},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.6208623051643372},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5437643527984619},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5401095747947693},{"id":"https://openalex.org/C200971846","wikidata":"https://www.wikidata.org/wiki/Q1420518","display_name":"Doubly fed electric machine","level":4,"score":0.5348552465438843},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.5063132047653198},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.48125454783439636},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.45743778347969055},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4207783341407776},{"id":"https://openalex.org/C189693848","wikidata":"https://www.wikidata.org/wiki/Q6031064","display_name":"Information exchange","level":2,"score":0.41948050260543823},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.41057026386260986},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.3436340093612671},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3307324945926666},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.14531907439231873},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.10178065299987793},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.05797448754310608},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccpis59145.2023.10291846","doi":"https://doi.org/10.1109/ccpis59145.2023.10291846","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccpis59145.2023.10291846","pdf_url":null,"source":{"id":"https://openalex.org/S7407086284","display_name":"International Conference on Circuits, Power and Intelligent Systems (CCPIS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 1st International Conference on Circuits, Power and Intelligent Systems (CCPIS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1844309481","https://openalex.org/W1965770844","https://openalex.org/W2158894763","https://openalex.org/W2215685717","https://openalex.org/W2324411161","https://openalex.org/W2471014650","https://openalex.org/W2501362497","https://openalex.org/W2675279495","https://openalex.org/W2729433550","https://openalex.org/W2754252319","https://openalex.org/W2899736073","https://openalex.org/W2910301662","https://openalex.org/W2959133376","https://openalex.org/W3010855582","https://openalex.org/W3043555389","https://openalex.org/W3043762782","https://openalex.org/W3123933050","https://openalex.org/W3215835691","https://openalex.org/W4211149899","https://openalex.org/W4285609064","https://openalex.org/W4288771489","https://openalex.org/W4292976700","https://openalex.org/W4293231674","https://openalex.org/W4313583800","https://openalex.org/W4317885443"],"related_works":["https://openalex.org/W4399564703","https://openalex.org/W2799989385","https://openalex.org/W4213448566","https://openalex.org/W2762215800","https://openalex.org/W2904328752","https://openalex.org/W4283746022","https://openalex.org/W2615943354","https://openalex.org/W4309153892","https://openalex.org/W3190836743","https://openalex.org/W7130507892"],"abstract_inverted_index":{"The":[0],"integration":[1],"of":[2,117],"a":[3,10,16,39],"Doubly":[4],"Fed":[5],"Induction":[6],"Generator":[7],"(DFIG)":[8],"and":[9,24,48,54,65,84,98,105],"Static":[11],"Synchronous":[12],"Compensator":[13],"(STATCOM)":[14],"in":[15,29,100],"coordinated":[17],"control":[18,41,58],"system":[19],"provides":[20],"enhanced":[21],"fault":[22,62,73,81,85,92,96],"analysis":[23],"mitigation":[25],"for":[26],"asymmetrical":[27,72],"faults":[28],"power":[30],"systems.":[31],"Through":[32],"the":[33,52,68,75,103,115,118],"Peer-to-Peer":[34],"(P2P)":[35],"Coordinated":[36,77],"Control":[37,78],"System,":[38],"distributed":[40],"approach":[42],"is":[43],"implemented,":[44],"enabling":[45],"effective":[46],"communication":[47],"information":[49,97],"exchange":[50],"between":[51,67],"DFIG":[53,104],"STATCOM.":[55],"This":[56],"cooperative":[57],"strategy":[59],"ensures":[60],"efficient":[61],"detection,":[63],"isolation,":[64],"coordination":[66],"two":[69],"devices.":[70],"During":[71],"conditions,":[74],"P2P":[76],"System":[79],"employs":[80],"detection":[82],"algorithms":[83],"location":[86],"estimation":[87],"techniques":[88],"to":[89,113],"perform":[90],"real-time":[91],"analysis.":[93],"By":[94],"sharing":[95],"collaborating":[99],"decision-making":[101],"processes,":[102],"STATCOM":[106],"can":[107],"promptly":[108],"adjust":[109],"their":[110],"operating":[111],"characteristics":[112],"mitigate":[114],"impact":[116],"fault.":[119]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2023-10-28T00:00:00"}
