{"id":"https://openalex.org/W4385893201","doi":"https://doi.org/10.1109/eeeic/icpseurope57605.2023.10194812","title":"Design of a Low-Voltage Mock-Up of a New Multi-Terminal Italian HVDC Transmission System","display_name":"Design of a Low-Voltage Mock-Up of a New Multi-Terminal Italian HVDC Transmission System","publication_year":2023,"publication_date":"2023-06-06","ids":{"openalex":"https://openalex.org/W4385893201","doi":"https://doi.org/10.1109/eeeic/icpseurope57605.2023.10194812"},"language":"en","primary_location":{"id":"doi:10.1109/eeeic/icpseurope57605.2023.10194812","doi":"https://doi.org/10.1109/eeeic/icpseurope57605.2023.10194812","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/eeeic/icpseurope57605.2023.10194812","pdf_url":null,"source":{"id":"https://openalex.org/S4363607938","display_name":"IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE International Conference on Environment and Electrical Engineering and 2023 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&amp;CPS Europe)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043038150","display_name":"Francesca Pizzimenti","orcid":"https://orcid.org/0000-0003-4144-4700","observed_orcids":["https://orcid.org/0000-0003-4144-4700"]},"institutions":[{"id":"https://openalex.org/I861853513","display_name":"Sapienza University of Rome","ror":"https://ror.org/02be6w209","country_code":"IT","type":"education","lineage":["https://openalex.org/I861853513"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Francesca Pizzimenti","raw_affiliation_strings":["Sapienza University of Rome, Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sapienza University of Rome, Rome, Italy","institution_ids":["https://openalex.org/I861853513"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061657488","display_name":"S. Lauria","orcid":"https://orcid.org/0000-0002-9908-1255","observed_orcids":["https://orcid.org/0000-0002-9908-1255"]},"institutions":[{"id":"https://openalex.org/I861853513","display_name":"Sapienza University of Rome","ror":"https://ror.org/02be6w209","country_code":"IT","type":"education","lineage":["https://openalex.org/I861853513"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Stefano Lauria","raw_affiliation_strings":["Sapienza University of Rome, Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sapienza University of Rome, Rome, Italy","institution_ids":["https://openalex.org/I861853513"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027977986","display_name":"Fabio Giulii Capponi","orcid":"https://orcid.org/0000-0002-9121-9889","observed_orcids":["https://orcid.org/0000-0002-9121-9889"]},"institutions":[{"id":"https://openalex.org/I861853513","display_name":"Sapienza University of Rome","ror":"https://ror.org/02be6w209","country_code":"IT","type":"education","lineage":["https://openalex.org/I861853513"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Fabio Giulii Capponi","raw_affiliation_strings":["Sapienza University of Rome, Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sapienza University of Rome, Rome, Italy","institution_ids":["https://openalex.org/I861853513"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000740785","display_name":"Luca Buono","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210101959","display_name":"Terna (Italy)","ror":"https://ror.org/013nb7b55","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210101959"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Luca Buono","raw_affiliation_strings":["Terna S.p.A., Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Terna S.p.A., Rome, Italy","institution_ids":["https://openalex.org/I4210101959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009989179","display_name":"Francesco Palone","orcid":"https://orcid.org/0000-0001-6414-7675","observed_orcids":["https://orcid.org/0000-0001-6414-7675"]},"institutions":[{"id":"https://openalex.org/I4210101959","display_name":"Terna (Italy)","ror":"https://ror.org/013nb7b55","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210101959"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Francesco Palone","raw_affiliation_strings":["Terna S.p.A., Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Terna S.p.A., Rome, Italy","institution_ids":["https://openalex.org/I4210101959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088818324","display_name":"Roberto Spezie","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210101959","display_name":"Terna (Italy)","ror":"https://ror.org/013nb7b55","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210101959"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Spezie","raw_affiliation_strings":["Terna S.p.A., Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Terna S.p.A., Rome, Italy","institution_ids":["https://openalex.org/I4210101959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5092496251","display_name":"Gabriele Tresso","orcid":"https://orcid.org/0009-0009-0643-0427","observed_orcids":["https://orcid.org/0009-0009-0643-0427"]},"institutions":[{"id":"https://openalex.org/I4210101959","display_name":"Terna (Italy)","ror":"https://ror.org/013nb7b55","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210101959"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Gabriele Tresso","raw_affiliation_strings":["Terna S.p.A., Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Terna S.p.A., Rome, Italy","institution_ids":["https://openalex.org/I4210101959"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5092496252","display_name":"Pierluigi Vacante","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210101959","display_name":"Terna (Italy)","ror":"https://ror.org/013nb7b55","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210101959"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Pierluigi Vacante","raw_affiliation_strings":["Terna S.p.A., Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Terna S.p.A., Rome, Italy","institution_ids":["https://openalex.org/I4210101959"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4481,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.41119639,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/multiterminal-hvdc","display_name":"multi-terminal HVDC","score":0.9300000071525574},{"id":"https://openalex.org/keywords/hvdc-circuit-breakers","display_name":"HVDC circuit breakers","score":0.968999981880188},{"id":"https://openalex.org/keywords/scale-model","display_name":"scale model","score":0.6029999852180481},{"id":"https://openalex.org/keywords/electromagnetic-transient-analysis","display_name":"electromagnetic transient analysis","score":0.7760000228881836},{"id":"https://openalex.org/keywords/clean-energy-transition","display_name":"clean energy transition","score":0.7289999723434448},{"id":"https://openalex.org/keywords/renewable-energy-interconnection","display_name":"renewable energy interconnection","score":0.7820000052452087}],"concepts":[{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.7083343267440796},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.696959912776947},{"id":"https://openalex.org/C2779664074","wikidata":"https://www.wikidata.org/wiki/Q3518405","display_name":"Terminal (telecommunication)","level":2,"score":0.6673176884651184},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.6242830157279968},{"id":"https://openalex.org/C2780615140","wikidata":"https://www.wikidata.org/wiki/Q920419","display_name":"Upgrade","level":2,"score":0.6152528524398804},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5659885406494141},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.5609475374221802},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5455358624458313},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.5390055179595947},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.515347421169281},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.5105420351028442},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44681835174560547},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.4304150342941284},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.4225218594074249},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.36876171827316284},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.3383343517780304},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3347911834716797},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.19843026995658875},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/eeeic/icpseurope57605.2023.10194812","doi":"https://doi.org/10.1109/eeeic/icpseurope57605.2023.10194812","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/eeeic/icpseurope57605.2023.10194812","pdf_url":null,"source":{"id":"https://openalex.org/S4363607938","display_name":"IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE International Conference on Environment and Electrical Engineering and 2023 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&amp;CPS Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:iris.uniroma1.it:11573/1687393","doi":null,"is_oa":false,"landing_page_url":"https://hdl.handle.net/11573/1687393","pdf_url":null,"source":{"id":"https://openalex.org/S4377196107","display_name":"IRIS Research product catalog (Sapienza University of Rome)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":1.0,"display_name":"Industry, innovation and infrastructure"},{"id":"https://metadata.un.org/sdg/7","score":0.878000020980835,"display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2147640475","https://openalex.org/W2549788447","https://openalex.org/W2950634899","https://openalex.org/W3037132975","https://openalex.org/W3038138161","https://openalex.org/W3177623808"],"related_works":["https://openalex.org/W6996892149","https://openalex.org/W2168293425","https://openalex.org/W4385893208","https://openalex.org/W7034704584","https://openalex.org/W7214835657","https://openalex.org/W7214853617","https://openalex.org/W2315257103","https://openalex.org/W2949737776","https://openalex.org/W4256352542","https://openalex.org/W2779004652"],"abstract_inverted_index":{"High":[0],"Voltage":[1],"Direct":[2],"Current":[3],"(HVDC)":[4],"transmission":[5,50],"systems,":[6],"especially":[7],"in":[8,20,78,126],"multi-terminal":[9,49],"configuration,":[10],"are":[11],"expected":[12,132],"to":[13,62,64,106],"help":[14],"accelerating":[15],"the":[16,23,45,60,65,96,109,127,131],"green":[17],"energy":[18,28],"transition":[19],"Europe,":[21],"allowing":[22],"interconnections":[24],"with":[25,59,98,142],"remote":[26],"renewable":[27],"production":[29],"sites.":[30],"The":[31,121],"SACOI2":[32],"HVDC":[33,71],"system,":[34,111],"operated":[35],"by":[36],"Terna":[37],"S.p.A":[38],"and":[39,52,101,114],"\u00c9lectricit\u00e9":[40],"de":[41],"France":[42],"S.A.,":[43],"is":[44,53,112],"only":[46],"operating":[47],"European":[48],"system":[51],"currently":[54],"undergoing":[55],"a":[56,79,135],"refurbishment":[57],"phase":[58],"aim":[61],"upgrade":[63],"new":[66],"SACOI3.":[67],"Recent":[68],"developments":[69],"on":[70],"circuit":[72],"breakers":[73],"(CBs)":[74],"suggest":[75],"further":[76],"investigation":[77],"possible":[80],"adoption":[81],"of":[82,95,134],"half-bridge":[83],"VSC":[84],"(HB-VSC)":[85],"converters.":[86],"In":[87],"this":[88],"paper,":[89],"an":[90],"experimental":[91],"low":[92],"voltage":[93,100],"prototype":[94],"SACOI3":[97,137],"scaled":[99],"current":[102],"values,":[103],"being":[104],"able":[105],"reproduce":[107],"accurately":[108],"full-scale":[110],"designed":[113],"tested":[115],"through":[116],"electromagnetic":[117],"transient":[118],"analysis":[119],"tools.":[120],"reduced":[122],"scale":[123],"mock-up":[124],"examined":[125],"paper":[128],"will":[129],"investigate":[130],"performances":[133],"future":[136],"link":[138],"using":[139],"HB-VSC":[140],"converters,":[141],"experimentally":[143],"measurable":[144],"results.":[145]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2023-08-18T00:00:00"}
