{"id":"https://openalex.org/W4385719476","doi":"https://doi.org/10.1117/12.2689620","title":"Research on single-phase grounding fault detection method based on vision transformer","display_name":"Research on single-phase grounding fault detection method based on vision transformer","publication_year":2023,"publication_date":"2023-08-10","ids":{"openalex":"https://openalex.org/W4385719476","doi":"https://doi.org/10.1117/12.2689620"},"language":"en","primary_location":{"id":"doi:10.1117/12.2689620","doi":"https://doi.org/10.1117/12.2689620","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.2689620","pdf_url":null,"source":{"id":"https://openalex.org/S4363608196","display_name":"International Conference on Information Science, Electrical and Automation Engineering (ISEAE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"5th International Conference on Information Science, Electrical, and Automation Engineering (ISEAE 2023)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100427992","display_name":"Ting Wang","orcid":"https://orcid.org/0000-0003-1144-8700","observed_orcids":["https://orcid.org/0000-0003-1144-8700"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ting Wang","raw_affiliation_strings":["Liaoning Electric Power Co., Ltd. (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Liaoning Electric Power Co., Ltd. (China)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017910487","display_name":"Guanhua Li","orcid":"https://orcid.org/0000-0002-8250-0628","observed_orcids":["https://orcid.org/0000-0002-8250-0628"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Guanhua Li","raw_affiliation_strings":["Liaoning Electric Power Co., Ltd. (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Liaoning Electric Power Co., Ltd. (China)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114153456","display_name":"Shicong Sun","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shicong Sun","raw_affiliation_strings":["Liaoning Electric Power Co., Ltd. (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Liaoning Electric Power Co., Ltd. (China)","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Ke Huang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ke Huang","raw_affiliation_strings":["Liaoning Electric Power Co., Ltd. (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Liaoning Electric Power Co., Ltd. (China)","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5102674107","display_name":"Yiling Ma","orcid":"https://orcid.org/0009-0002-7610-2014","observed_orcids":["https://orcid.org/0009-0002-7610-2014"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yiling Ma","raw_affiliation_strings":["Liaoning Electric Power Co., Ltd. (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Liaoning Electric Power Co., Ltd. (China)","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.12145334,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"112","last_page":"112"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/single-line-to-ground-fault","display_name":"single-phase grounding fault","score":0.8109999895095825},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.9210000038146973},{"id":"https://openalex.org/keywords/power-distribution-networks","display_name":"power distribution networks","score":0.9700000286102295},{"id":"https://openalex.org/keywords/vision-transformer","display_name":"vision transformer","score":0.9319999814033508},{"id":"https://openalex.org/keywords/zero-sequence-current","display_name":"zero-sequence current","score":0.9860000014305115},{"id":"https://openalex.org/keywords/gramian-angular-field","display_name":"Gramian Angular Field","score":0.9549999833106995},{"id":"https://openalex.org/keywords/fault-classification","display_name":"fault classification","score":0.5320000052452087}],"concepts":[{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.8613157868385315},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5714459419250488},{"id":"https://openalex.org/C165296897","wikidata":"https://www.wikidata.org/wiki/Q552380","display_name":"Symmetrical components","level":4,"score":0.4872797727584839},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.47445663809776306},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.4692034125328064},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4572356343269348},{"id":"https://openalex.org/C78779171","wikidata":"https://www.wikidata.org/wiki/Q432571","display_name":"Earthing system","level":3,"score":0.45129650831222534},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.44747066497802734},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4380246698856354},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3713850975036621},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.32714980840682983},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2683493494987488},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17131423950195312},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1117/12.2689620","doi":"https://doi.org/10.1117/12.2689620","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.2689620","pdf_url":null,"source":{"id":"https://openalex.org/S4363608196","display_name":"International Conference on Information Science, Electrical and Automation Engineering (ISEAE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"5th International Conference on Information Science, Electrical, and Automation Engineering (ISEAE 2023)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"sustainable_development_goals_aurora":[{"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11","score":0.46000000834465027}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2923780625","https://openalex.org/W3010789805","https://openalex.org/W3134100778","https://openalex.org/W3187418919","https://openalex.org/W3216277706","https://openalex.org/W4200186424","https://openalex.org/W4206437023","https://openalex.org/W4232666001","https://openalex.org/W4250685322","https://openalex.org/W4312204520","https://openalex.org/W4323050469"],"related_works":["https://openalex.org/W4415179619","https://openalex.org/W2048903656","https://openalex.org/W4393379258","https://openalex.org/W2115250844","https://openalex.org/W4407403363","https://openalex.org/W2361021394","https://openalex.org/W4317437812","https://openalex.org/W4408852424","https://openalex.org/W2125855483","https://openalex.org/W4393378188"],"abstract_inverted_index":{"In":[0,56,84],"China's":[1],"power":[2,68,72],"distribution":[3,43,101,215],"network,":[4,44,102],"low-current":[5,22,210],"grounding":[6,23,97,211],"is":[7,13,141,149,167],"mainly":[8],"used.":[9],"Single-phase":[10],"ground":[11,38,92,109,138,184,206],"fault":[12,39,110,139],"one":[14],"of":[15,66,90,99,124,132,178,182,213],"the":[16,21,42,63,67,88,95,100,115,121,128,133,136,144,156,163,170,176,180,195,199,209,214],"most":[17],"common":[18],"faults":[19,93,207],"in":[20,31,41,74,94,208],"mode.":[24],"If":[25],"effective":[26],"measures":[27],"are":[28],"not":[29],"taken":[30],"a":[32,36,48,106,152],"timely":[33],"manner":[34],"when":[35],"single-phase":[37,91,108,137,183,205],"occurs":[40],"it":[45,59],"will":[46],"pose":[47],"safety":[49,82],"threat":[50],"to":[51,79,86,174],"pedestrians":[52],"and":[53,77,194],"inspection":[54],"personnel.":[55],"serious":[57],"cases,":[58],"can":[60,202],"also":[61],"affect":[62],"stable":[64],"operation":[65],"grid":[69],"system,":[70],"cause":[71],"outages":[73],"other":[75],"areas,":[76],"lead":[78],"even":[80],"greater":[81],"hazards.":[83],"order":[85],"detect":[87,204],"occurrence":[89,181],"lowcurrent":[96],"mode":[98,212],"this":[103],"paper":[104],"proposes":[105],"new":[107],"detection":[111],"method":[112],"based":[113],"on":[114,190],"vision":[116,171],"transformer":[117,172],"algorithm,":[118],"combined":[119],"with":[120],"steady-state":[122],"characteristics":[123],"zero-sequence":[125,129,146],"current.":[126],"First,":[127],"current":[130,147],"data":[131,148],"line":[134],"where":[135],"occurred":[140],"sampled.":[142],"Secondly,":[143],"time-series":[145],"transformed":[150,164],"into":[151],"two-dimensional":[153,165],"image":[154,166],"using":[155,169],"Gramian":[157],"Angular":[158],"Field":[159],"(GAF)":[160],"method.":[161],"Finally,":[162],"classified":[168],"algorithm":[173,187,201],"achieve":[175],"purpose":[177],"detecting":[179],"faults.":[185],"The":[186],"was":[188],"verified":[189],"an":[191],"experimental":[192],"platform,":[193],"results":[196],"show":[197],"that":[198],"proposed":[200],"effectively":[203],"network.":[216]},"counts_by_year":[],"updated_date":"2026-10-14T16:39:01.820549","created_date":"2023-08-11T00:00:00"}