{"id":"https://openalex.org/W4366147353","doi":"https://doi.org/10.1109/apscon56343.2023.10101042","title":"Design and Optimization of a Wearable Sonomyography Sensor for Dynamic Muscle Activity Monitoring","display_name":"Design and Optimization of a Wearable Sonomyography Sensor for Dynamic Muscle Activity Monitoring","publication_year":2023,"publication_date":"2023-01-23","ids":{"openalex":"https://openalex.org/W4366147353","doi":"https://doi.org/10.1109/apscon56343.2023.10101042"},"language":"en","primary_location":{"id":"doi:10.1109/apscon56343.2023.10101042","doi":"https://doi.org/10.1109/apscon56343.2023.10101042","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apscon56343.2023.10101042","pdf_url":null,"source":{"id":"https://openalex.org/S7407087119","display_name":"IEEE Applied Sensing Conference (APSCON)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE Applied Sensing Conference (APSCON)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003895441","display_name":"Anne Tryphosa Kamatham","orcid":"https://orcid.org/0000-0002-5058-6156","observed_orcids":["https://orcid.org/0000-0002-5058-6156"]},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Anne Tryphosa Kamatham","raw_affiliation_strings":["Indian Institute of Technology,Centre for Biomedical Engineering,Delhi,India","Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Centre for Biomedical Engineering,Delhi,India","institution_ids":["https://openalex.org/I68891433"]},{"raw_affiliation_string":"Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, India","institution_ids":["https://openalex.org/I68891433"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069186378","display_name":"Biswarup Mukherjee","orcid":"https://orcid.org/0000-0001-5528-3763","observed_orcids":["https://orcid.org/0000-0001-5528-3763"]},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Biswarup Mukherjee","raw_affiliation_strings":["Indian Institute of Technology,Centre for Biomedical Engineering,Delhi,India","Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Centre for Biomedical Engineering,Delhi,India","institution_ids":["https://openalex.org/I68891433"]},{"raw_affiliation_string":"Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, India","institution_ids":["https://openalex.org/I68891433"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I68891433"],"apc_list":null,"apc_paid":null,"fwci":2.4345,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.87550201,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"3"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.611299991607666,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.611299991607666,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10727","display_name":"Ultrasound Imaging and Elastography","score":0.18979999423027039,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10662","display_name":"Ultrasonics and Acoustic Wave Propagation","score":0.08879999816417694,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sonomyography","display_name":"sonomyography","score":0.9959999918937683},{"id":"https://openalex.org/keywords/muscle-activity-monitoring","display_name":"muscle activity monitoring","score":0.8920000195503235},{"id":"https://openalex.org/keywords/ultrasonic-transducer-design","display_name":"ultrasonic transducer design","score":0.8830000162124634}],"concepts":[{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.7880340814590454},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.7583587765693665},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.6489444971084595},{"id":"https://openalex.org/C143753070","wikidata":"https://www.wikidata.org/wiki/Q162564","display_name":"Ultrasound","level":2,"score":0.610192596912384},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5761048793792725},{"id":"https://openalex.org/C2780226545","wikidata":"https://www.wikidata.org/wiki/Q6888030","display_name":"Modality (human\u2013computer interaction)","level":2,"score":0.5537315607070923},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.4824691116809845},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.4803094267845154},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4159848392009735},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3722562789916992},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.34052953124046326},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.33751440048217773},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.2884046733379364},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1734616458415985},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1463802456855774},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.11041605472564697},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.0},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/apscon56343.2023.10101042","doi":"https://doi.org/10.1109/apscon56343.2023.10101042","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apscon56343.2023.10101042","pdf_url":null,"source":{"id":"https://openalex.org/S7407087119","display_name":"IEEE Applied Sensing Conference (APSCON)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE Applied Sensing Conference (APSCON)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"sustainable_development_goals_aurora":[{"display_name":"Affordable and clean energy","score":0.6200000047683716,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1969563952","https://openalex.org/W1987548789","https://openalex.org/W2001301966","https://openalex.org/W2767053645","https://openalex.org/W2887073718","https://openalex.org/W2967217387","https://openalex.org/W3045443807","https://openalex.org/W3093545732","https://openalex.org/W3098988622","https://openalex.org/W3126644778","https://openalex.org/W3184052279","https://openalex.org/W4226124708","https://openalex.org/W4285302865"],"related_works":["https://openalex.org/W2012283803","https://openalex.org/W4384820447","https://openalex.org/W2072454424","https://openalex.org/W2117438306","https://openalex.org/W2185942010","https://openalex.org/W2260725127","https://openalex.org/W2366424944","https://openalex.org/W2089829884","https://openalex.org/W3034962873","https://openalex.org/W2351972135"],"abstract_inverted_index":{"Sonomyography":[0],"is":[1],"a":[2,29,86,97,102,145],"non-invasive":[3],"modality":[4,16],"that":[5,125],"uses":[6],"ultrasound":[7,40,47,66,88,99],"for":[8,90],"sensing":[9],"muscle":[10,20,91,155],"activity.":[11],"The":[12],"ability":[13],"of":[14,56,64,85,109,119,129,134,139,153],"this":[15,77],"to":[17,52,59,72,112,115],"robustly":[18],"sense":[19],"activity":[21,92,156],"with":[22,101],"good":[23],"resolution":[24],"makes":[25],"it":[26],"suitable":[27],"as":[28],"biomechatronic":[30],"control":[31],"interface.":[32],"However,":[33],"the":[34,54,62,65,83,117,120,127,132,135,140],"most":[35],"sonomyography-based":[36],"studies":[37],"utilize":[38],"B-mode":[39],"imaging":[41,48],"which":[42],"require":[43],"large":[44],"form-factor":[45],"clinical":[46],"devices.":[49],"In":[50,76],"order":[51],"extend":[53],"utility":[55],"sonomyography":[57,147],"techniques":[58],"wearable":[60,87,146],"systems,":[61],"size":[63],"system":[67],"and":[68,81,149],"associated":[69],"sensors":[70],"needs":[71],"be":[73],"greatly":[74],"reduced.":[75],"paper,":[78],"we":[79,143],"design":[80],"optimize":[82,116],"performance":[84],"sensor":[89,148],"monitoring":[93],"applications.":[94],"We":[95],"fabricated":[96],"custom":[98],"transducer":[100,141],"backing":[103],"layer":[104],"by":[105],"mixing":[106],"varying":[107],"amounts":[108],"Tungsten":[110,130],"powder":[111],"epoxy":[113],"resin":[114],"bandwidth":[118,133],"transducer.":[121],"Our":[122],"results":[123],"showed":[124],"increasing":[126],"proportion":[128],"improves":[131],"transducers.":[136],"Following":[137],"optimization":[138],"design,":[142],"developed":[144],"demonstrated":[150],"real-time":[151],"measurement":[152],"dynamic":[154],"during":[157],"hand":[158],"open-close":[159],"movement.":[160]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2025-10-10T00:00:00"}
