{"id":"https://openalex.org/W4352980957","doi":"https://doi.org/10.1109/npsc57038.2022.10069457","title":"Improved Protection Scheme for High Voltage Transmission Lines Connecting Large-Scale Solar PV Plants","display_name":"Improved Protection Scheme for High Voltage Transmission Lines Connecting Large-Scale Solar PV Plants","publication_year":2022,"publication_date":"2022-12-17","ids":{"openalex":"https://openalex.org/W4352980957","doi":"https://doi.org/10.1109/npsc57038.2022.10069457"},"language":"en","primary_location":{"id":"doi:10.1109/npsc57038.2022.10069457","doi":"https://doi.org/10.1109/npsc57038.2022.10069457","is_oa":false,"landing_page_url":"https://doi.org/10.1109/npsc57038.2022.10069457","pdf_url":null,"source":{"id":"https://openalex.org/S4306420581","display_name":"National Power Systems Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 22nd National Power Systems Conference (NPSC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Sikander Singh","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sikander Singh","raw_affiliation_strings":["IIT(ISM) Dhanbad,Department of Electrical Engineering,Dhanbad,India","Department of Electrical Engineering, IIT(ISM) Dhanbad, Dhanbad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT(ISM) Dhanbad,Department of Electrical Engineering,Dhanbad,India","institution_ids":["https://openalex.org/I189109744"]},{"raw_affiliation_string":"Department of Electrical Engineering, IIT(ISM) Dhanbad, Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041200766","display_name":"Paresh Kumar Nayak","orcid":"https://orcid.org/0000-0001-6853-3266","observed_orcids":["https://orcid.org/0000-0001-6853-3266"]},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Paresh Kumar Nayak","raw_affiliation_strings":["IIT(ISM) Dhanbad,Department of Electrical Engineering,Dhanbad,India","Department of Electrical Engineering, IIT(ISM) Dhanbad, Dhanbad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT(ISM) Dhanbad,Department of Electrical Engineering,Dhanbad,India","institution_ids":["https://openalex.org/I189109744"]},{"raw_affiliation_string":"Department of Electrical Engineering, IIT(ISM) Dhanbad, Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112433529","display_name":"Saumendra Sarangi","orcid":"https://orcid.org/0000-0001-6207-9541","observed_orcids":["https://orcid.org/0000-0001-6207-9541"]},"institutions":[{"id":"https://openalex.org/I152869788","display_name":"Motilal Nehru National Institute of Technology","ror":"https://ror.org/04dp7tp96","country_code":"IN","type":"education","lineage":["https://openalex.org/I152869788"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Saumendra Sarangi","raw_affiliation_strings":["MNNIT Allahabad,Department of Electrical Engineering,Prayagraj,India","Department of Electrical Engineering, MNNIT Allahabad, Prayagraj, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"MNNIT Allahabad,Department of Electrical Engineering,Prayagraj,India","institution_ids":["https://openalex.org/I152869788"]},{"raw_affiliation_string":"Department of Electrical Engineering, MNNIT Allahabad, Prayagraj, India","institution_ids":["https://openalex.org/I152869788"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5006515404","display_name":"Sauvik Biswas","orcid":"https://orcid.org/0000-0003-0394-0164","observed_orcids":["https://orcid.org/0000-0003-0394-0164"]},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sauvik Biswas","raw_affiliation_strings":["IIT Delhi,Department of Electrical Engineering,Delhi,India","Department of Electrical Engineering, IIT Delhi, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT Delhi,Department of Electrical Engineering,Delhi,India","institution_ids":["https://openalex.org/I68891433"]},{"raw_affiliation_string":"Department of Electrical Engineering, IIT Delhi, Delhi, India","institution_ids":["https://openalex.org/I68891433"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.742,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.82454374,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"118","last_page":"123"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/distance-relaying","display_name":"distance relaying","score":0.7540000081062317},{"id":"https://openalex.org/keywords/fault-ride-through","display_name":"fault ride-through","score":0.47099998593330383},{"id":"https://openalex.org/keywords/high-voltage-power-lines","display_name":"high-voltage transmission lines","score":0.6779999732971191},{"id":"https://openalex.org/keywords/apparent-power","display_name":"apparent power","score":0.5479999780654907},{"id":"https://openalex.org/keywords/fault-location-identification","display_name":"fault location estimation","score":0.8149999976158142},{"id":"https://openalex.org/keywords/ground-faults","display_name":"ground faults","score":0.6539999842643738}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6910632252693176},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6739002466201782},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.6180589199066162},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.6124443411827087},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.5701202750205994},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5005624294281006},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4915333688259125},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.4721370339393616},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.4610940217971802},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4060829281806946},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4056071639060974},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4038563668727875},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3873836398124695},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3404770493507385},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08290991187095642},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/npsc57038.2022.10069457","doi":"https://doi.org/10.1109/npsc57038.2022.10069457","is_oa":false,"landing_page_url":"https://doi.org/10.1109/npsc57038.2022.10069457","pdf_url":null,"source":{"id":"https://openalex.org/S4306420581","display_name":"National Power Systems Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 22nd National Power Systems Conference (NPSC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":1.0},{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9853000044822693}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W583058156","https://openalex.org/W1966172613","https://openalex.org/W2124086911","https://openalex.org/W2158763508","https://openalex.org/W2177732305","https://openalex.org/W2761746967","https://openalex.org/W2883919122","https://openalex.org/W2898302362","https://openalex.org/W2902112362","https://openalex.org/W2935101917","https://openalex.org/W2966014368","https://openalex.org/W2980017073","https://openalex.org/W2980090601","https://openalex.org/W3003051976","https://openalex.org/W3008542950","https://openalex.org/W3033312283","https://openalex.org/W3215755163","https://openalex.org/W4205524459","https://openalex.org/W4206765836"],"related_works":["https://openalex.org/W4388039496","https://openalex.org/W3008542950","https://openalex.org/W4403204462","https://openalex.org/W2567896591","https://openalex.org/W4313291300","https://openalex.org/W2616852534","https://openalex.org/W4317938024","https://openalex.org/W6968269988","https://openalex.org/W2902112362","https://openalex.org/W4406974920"],"abstract_inverted_index":{"The":[0,175],"fault":[1,14,119,130,159,167],"current":[2,108],"characteristics":[3],"of":[4,114,177],"power":[5,28,82],"electronics":[6],"interfaced":[7],"large-scale":[8,39],"solar":[9,40,70],"photovoltaic":[10],"(PV)":[11],"plants":[12],"satisfying":[13],"ride":[15],"through":[16,188],"requirement":[17],"are":[18],"quite":[19],"different":[20],"compared":[21],"to":[22,56,128,147],"the":[23,31,58,79,85,95,102,111,115,118,124,129,138,142,149,154,165,170,178],"traditionally":[24],"used":[25,67],"synchronous":[26],"generator-based":[27],"system.":[29],"Consequently,":[30],"conventional":[32,63],"distance":[33,51,64,145,173],"relaying":[34,52],"scheme":[35],"face":[36],"underreaching":[37,59],"problem":[38,60],"PV":[41,71,86,143,155,171],"plant":[42,72],"connected":[43,73],"transmission":[44,74,97],"lines.":[45,75],"In":[46,76],"this":[47,77],"paper,":[48],"a":[49,185],"modified":[50],"technique":[53],"is":[54,99,133,180],"proposed":[55],"overcome":[57],"faced":[61],"by":[62,141],"relay":[65,146,157],"while":[66],"for":[68],"protection":[69],"approach,":[78],"net":[80],"apparent":[81,116],"supplied":[83],"from":[84,137,169],"side":[87,90,144,156,172],"and":[88,107,122,135,158],"grid":[89],"during":[91],"ground":[92],"faults":[93],"in":[94,163],"interconnected":[96],"line":[98,103,151],"calculated":[100,112,134],"using":[101],"end":[104],"synchronized":[105],"voltage":[106],"measurements.":[109],"From":[110],"values":[113],"power,":[117],"path":[120,131],"resistance":[121,132],"hence":[123],"incremental":[125],"impedance":[126,139,152],"due":[127],"subtracted":[136],"seen":[140],"obtain":[148],"correct":[150,166],"between":[153],"point.":[160],"This":[161],"helps":[162],"estimating":[164],"location":[168],"relay.":[174],"efficacy":[176],"method":[179],"validated":[181],"data":[182],"simulated":[183],"on":[184],"2-bus":[186],"system":[187],"MATLAB/Simulink.":[189]},"counts_by_year":[{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":2}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2023-03-23T00:00:00"}
