{"id":"https://openalex.org/W4323925008","doi":"https://doi.org/10.1049/gtd2.12761","title":"Accounting for component condition and preventive retirement in power system reliability analyses","display_name":"Accounting for component condition and preventive retirement in power system reliability analyses","publication_year":2023,"publication_date":"2023-03-10","ids":{"openalex":"https://openalex.org/W4323925008","doi":"https://doi.org/10.1049/gtd2.12761"},"language":"en","primary_location":{"id":"doi:10.1049/gtd2.12761","doi":"https://doi.org/10.1049/gtd2.12761","is_oa":true,"landing_page_url":"https://doi.org/10.1049/gtd2.12761","pdf_url":"https://onlinelibrary.wiley.com/doi/pdfdirect/10.1049/gtd2.12761","source":{"id":"https://openalex.org/S71857517","display_name":"IET Generation Transmission & Distribution","issn_l":"1751-8687","issn":["1751-8687","1751-8695"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-2","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Generation, Transmission &amp; Distribution","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://onlinelibrary.wiley.com/doi/pdfdirect/10.1049/gtd2.12761","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5066817816","display_name":"H\u00e5kon Toftaker","orcid":"https://orcid.org/0000-0003-4605-4111","observed_orcids":["https://orcid.org/0000-0003-4605-4111"]},"institutions":[{"id":"https://openalex.org/I4210142273","display_name":"SINTEF Energy Research","ror":"https://ror.org/0590dbq33","country_code":"NO","type":"facility","lineage":["https://openalex.org/I173888879","https://openalex.org/I4210142273"]}],"countries":["NO"],"is_corresponding":true,"raw_author_name":"H\u00e5kon Toftaker","raw_affiliation_strings":["SINTEF Energy Research, Trondheim, Norway"],"raw_orcid":"https://orcid.org/0000-0003-4605-4111","affiliations":[{"raw_affiliation_string":"SINTEF Energy Research, Trondheim, Norway","institution_ids":["https://openalex.org/I4210142273"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029532233","display_name":"J\u00f8rn Foros","orcid":"https://orcid.org/0000-0003-3596-569X","observed_orcids":["https://orcid.org/0000-0003-3596-569X"]},"institutions":[{"id":"https://openalex.org/I4210142273","display_name":"SINTEF Energy Research","ror":"https://ror.org/0590dbq33","country_code":"NO","type":"facility","lineage":["https://openalex.org/I173888879","https://openalex.org/I4210142273"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"J\u00f8rn Foros","raw_affiliation_strings":["SINTEF Energy Research, Trondheim, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SINTEF Energy Research, Trondheim, Norway","institution_ids":["https://openalex.org/I4210142273"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5014742355","display_name":"Iver Bakken Sperstad","orcid":"https://orcid.org/0000-0002-4827-6431","observed_orcids":["https://orcid.org/0000-0002-4827-6431"]},"institutions":[{"id":"https://openalex.org/I4210142273","display_name":"SINTEF Energy Research","ror":"https://ror.org/0590dbq33","country_code":"NO","type":"facility","lineage":["https://openalex.org/I173888879","https://openalex.org/I4210142273"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Iver Bakken Sperstad","raw_affiliation_strings":["SINTEF Energy Research, Trondheim, Norway"],"raw_orcid":"https://orcid.org/0000-0002-4827-6431","affiliations":[{"raw_affiliation_string":"SINTEF Energy Research, Trondheim, Norway","institution_ids":["https://openalex.org/I4210142273"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5066817816"],"corresponding_institution_ids":["https://openalex.org/I4210142273"],"apc_list":{"value":2800,"currency":"USD","value_usd":2800},"apc_paid":{"value":2800,"currency":"USD","value_usd":2800},"fwci":1.5264,"has_fulltext":true,"cited_by_count":13,"citation_normalized_percentile":{"value":0.79925651,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"17","issue":"9","first_page":"1972","last_page":"1984"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.006099999882280827,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-system-reliability","display_name":"power system reliability","score":0.9490000009536743},{"id":"https://openalex.org/keywords/failure-probability","display_name":"failure probability","score":0.8199999928474426},{"id":"https://openalex.org/keywords/semi-markov-processes","display_name":"semi-Markov processes","score":0.9509999752044678},{"id":"https://openalex.org/keywords/markovian-approximation","display_name":"Markov approximation","score":0.9089999794960022},{"id":"https://openalex.org/keywords/power-transformers","display_name":"power transformers","score":0.9049999713897705},{"id":"https://openalex.org/keywords/risk-identification","display_name":"risk identification","score":0.48100000619888306}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.826436460018158},{"id":"https://openalex.org/C98763669","wikidata":"https://www.wikidata.org/wiki/Q176645","display_name":"Markov chain","level":2,"score":0.614739179611206},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6023492217063904},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.5873316526412964},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5584514141082764},{"id":"https://openalex.org/C163836022","wikidata":"https://www.wikidata.org/wiki/Q6771326","display_name":"Markov model","level":3,"score":0.45347076654434204},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.45141083002090454},{"id":"https://openalex.org/C159886148","wikidata":"https://www.wikidata.org/wiki/Q176645","display_name":"Markov process","level":2,"score":0.44464296102523804},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4403870105743408},{"id":"https://openalex.org/C63428231","wikidata":"https://www.wikidata.org/wiki/Q9043","display_name":"Norwegian","level":2,"score":0.4356813430786133},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43479594588279724},{"id":"https://openalex.org/C149782125","wikidata":"https://www.wikidata.org/wiki/Q160039","display_name":"Econometrics","level":1,"score":0.41423526406288147},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3030030429363251},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.19306135177612305},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.16250395774841309},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.10911300778388977},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.07442834973335266},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":7,"locations":[{"id":"doi:10.1049/gtd2.12761","doi":"https://doi.org/10.1049/gtd2.12761","is_oa":true,"landing_page_url":"https://doi.org/10.1049/gtd2.12761","pdf_url":"https://onlinelibrary.wiley.com/doi/pdfdirect/10.1049/gtd2.12761","source":{"id":"https://openalex.org/S71857517","display_name":"IET Generation Transmission & Distribution","issn_l":"1751-8687","issn":["1751-8687","1751-8695"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-2","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Generation, Transmission &amp; Distribution","raw_type":"journal-article"},{"id":"doi:10.36227/techrxiv.19362131.v2","doi":"https://doi.org/10.36227/techrxiv.19362131.v2","is_oa":true,"landing_page_url":"https://doi.org/10.36227/techrxiv.19362131.v2","pdf_url":null,"source":null,"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"},{"id":"doi:10.36227/techrxiv.19362131","doi":"https://doi.org/10.36227/techrxiv.19362131","is_oa":true,"landing_page_url":"https://doi.org/10.36227/techrxiv.19362131","pdf_url":"https://www.techrxiv.org/articles/preprint/Accounting_for_component_condition_and_preventive_retirement_in_power_system_reliability_of_supply_analyses/19362131/2/files/35778515.pdf","source":null,"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"TechRxiv","raw_type":"posted-content"},{"id":"doi:10.36227/techrxiv.19362131.v1","doi":"https://doi.org/10.36227/techrxiv.19362131.v1","is_oa":true,"landing_page_url":"https://doi.org/10.36227/techrxiv.19362131.v1","pdf_url":"https://www.techrxiv.org/articles/preprint/Accounting_for_component_condition_and_preventive_retirement_in_power_system_reliability_of_supply_analyses/19362131/1/files/34438853.pdf","source":null,"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"},{"id":"pmh:oai:doaj.org/article:9738c0b68fe645b0b8d401283f49c6e0","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/9738c0b68fe645b0b8d401283f49c6e0","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IET Generation, Transmission & Distribution, Vol 17, Iss 9, Pp 1972-1984 (2023)","raw_type":"article"},{"id":"pmh:oai:figshare.com:article/19362131","doi":null,"is_oa":true,"landing_page_url":"https://figshare.com/articles/preprint/Accounting_for_component_condition_and_preventive_retirement_in_power_system_reliability_of_supply_analyses/19362131","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Text"},{"id":"pmh:oai:sintef.brage.unit.no:11250/3065371","doi":null,"is_oa":true,"landing_page_url":"https://hdl.handle.net/11250/3065371","pdf_url":null,"source":{"id":"https://openalex.org/S7407064446","display_name":"NORA - Norwegian Open Research Archives","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IET Generation, Transmission &amp; Distribution","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1049/gtd2.12761","doi":"https://doi.org/10.1049/gtd2.12761","is_oa":true,"landing_page_url":"https://doi.org/10.1049/gtd2.12761","pdf_url":"https://onlinelibrary.wiley.com/doi/pdfdirect/10.1049/gtd2.12761","source":{"id":"https://openalex.org/S71857517","display_name":"IET Generation Transmission & Distribution","issn_l":"1751-8687","issn":["1751-8687","1751-8695"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-2","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Generation, Transmission &amp; Distribution","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.651199996471405,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G7738611548","display_name":null,"funder_award_id":"308781","funder_id":"https://openalex.org/F4320323299","funder_display_name":"Norges Forskningsr\u00e5d"}],"funders":[{"id":"https://openalex.org/F4320323299","display_name":"Norges Forskningsr\u00e5d","ror":"https://ror.org/00epmv149"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4323925008.pdf","grobid_xml":"https://content.openalex.org/works/W4323925008.grobid-xml"},"referenced_works_count":36,"referenced_works":["https://openalex.org/W1486460655","https://openalex.org/W1982927672","https://openalex.org/W1988400047","https://openalex.org/W2031757379","https://openalex.org/W2039904641","https://openalex.org/W2039921313","https://openalex.org/W2051542965","https://openalex.org/W2070645909","https://openalex.org/W2080493110","https://openalex.org/W2097995695","https://openalex.org/W2108161354","https://openalex.org/W2130198414","https://openalex.org/W2134021005","https://openalex.org/W2135172069","https://openalex.org/W2344200643","https://openalex.org/W2500834297","https://openalex.org/W2507948405","https://openalex.org/W2516588314","https://openalex.org/W2746633539","https://openalex.org/W2767672119","https://openalex.org/W2767762497","https://openalex.org/W2792128614","https://openalex.org/W2885849834","https://openalex.org/W2887317940","https://openalex.org/W2890403786","https://openalex.org/W2998435143","https://openalex.org/W3006332205","https://openalex.org/W3082011739","https://openalex.org/W3082692473","https://openalex.org/W3096656449","https://openalex.org/W3147033875","https://openalex.org/W4233741721","https://openalex.org/W4293078418","https://openalex.org/W4293078572","https://openalex.org/W4293860495","https://openalex.org/W4393630742"],"related_works":["https://openalex.org/W4293078572","https://openalex.org/W2560663152","https://openalex.org/W2151478443","https://openalex.org/W2044939311","https://openalex.org/W2031096499","https://openalex.org/W2955032832","https://openalex.org/W2113010277","https://openalex.org/W4399530254","https://openalex.org/W2387058441","https://openalex.org/W3023344766"],"abstract_inverted_index":{"Abstract":[0],"Deteriorated":[1],"power":[2,58,115,122],"system":[3,59],"components":[4,23],"have":[5],"a":[6,45,49,57,68,84],"higher":[7],"probability":[8,31,52],"of":[9,17,24,32,39,53,126,143,150,157,169,181,189],"failure":[10,54],"than":[11],"new":[12],"components.":[13,41],"Still,":[14],"the":[15,25,29,37,72,91,95,120,124,132,140,148,151,155,167,170,176,179,187,192],"reliability":[16,60,180],"supply":[18],"analyses":[19],"traditionally":[20],"models":[21],"all":[22],"same":[26,30],"type":[27],"with":[28],"failure,":[33],"and":[34,71,93,101],"thus":[35,185],"neglects":[36],"effect":[38],"deteriorated":[40],"This":[42],"paper":[43,73,184],"presents":[44],"methodology":[46,164],"to":[47,97,104,131,139,175,178],"integrate":[48],"condition\u2010dependent":[50],"component":[51,63,193],"model":[55,96],"into":[56],"analysis.":[61],"The":[62,87,163,183],"state":[64],"is":[65,135],"described":[66],"by":[67,83],"semi\u2010Markov":[69],"process,":[70],"shows":[74,117],"how":[75],"this,":[76],"under":[77],"reasonable":[78],"assumptions,":[79],"can":[80,160],"be":[81,102,161],"approximated":[82],"Markov":[85,88],"process.":[86],"assumption":[89],"simplifies":[90],"analysis":[92],"allows":[94],"include":[98],"preventive":[99,144],"retirement":[100],"calibrated":[103],"statistical":[105,111],"data.":[106],"A":[107],"case":[108],"study":[109],"using":[110],"data":[112],"for":[113,191],"Norwegian":[114,121],"transformers":[116,152,171],"that,":[118],"in":[119,195],"system,":[123],"proportion":[125],"failures":[127],"that":[128,172],"are":[129],"due":[130,138],"poor":[133,158],"condition":[134,149,194],"small,":[136],"partly":[137],"common":[141],"strategy":[142],"retirement.":[145],"However,":[146],"if":[147],"were":[153],"worse,":[154],"impact":[156],"conditions":[159],"considerable.":[162],"further":[165],"enables":[166],"identification":[168],"contribute":[173],"most":[174],"risk":[177],"supply.":[182],"highlights":[186],"importance":[188],"accounting":[190],"strategic":[196],"decisions":[197],"such":[198],"as":[199],"long\u2010term":[200],"renewal":[201],"planning":[202]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":3}],"updated_date":"2026-11-09T13:22:03.289127","created_date":"2023-03-12T00:00:00"}
