{"id":"https://openalex.org/W4312371056","doi":"https://doi.org/10.1109/ess57819.2022.9969330","title":"Quasi-bilateral method for determining the distance to the ground fault of unilateral power lines","display_name":"Quasi-bilateral method for determining the distance to the ground fault of unilateral power lines","alternate_titles":[],"publication_year":2022,"publication_date":"2022-10-12","ids":{"openalex":"https://openalex.org/W4312371056","doi":"https://doi.org/10.1109/ess57819.2022.9969330"},"language":"en","primary_location":{"id":"doi:10.1109/ess57819.2022.9969330","doi":"https://doi.org/10.1109/ess57819.2022.9969330","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ess57819.2022.9969330","pdf_url":null,"source":{"id":"https://openalex.org/S7407087480","display_name":"IEEE International Conference on Energy Smart Systems (ESS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W4312371056"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024265752","display_name":"\u041c. \u0412. \u0413\u0440\u0435\u0431\u0447\u0435\u043d\u043a\u043e","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I208086522","display_name":"National University of Life and Environmental Sciences of Ukraine","ror":"https://ror.org/0441cbj57","country_code":"UA","type":"education","lineage":["https://openalex.org/I208086522"]}],"countries":["UA"],"is_corresponding":false,"raw_author_name":"Mykola Grebchenko","raw_affiliation_strings":["Education and research institute of Energetic, Automatic and Energy saving National University of Life and Environmental Sciences of Ukraine, Kyiv, Ukraine"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Education and research institute of Energetic, Automatic and Energy saving National University of Life and Environmental Sciences of Ukraine, Kyiv, Ukraine","institution_ids":["https://openalex.org/I208086522"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028101802","display_name":"M.F. Sopel","orcid":"https://orcid.org/0000-0002-3438-5848","observed_orcids":["https://orcid.org/0000-0002-3438-5848"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mykhailo Sopel","raw_affiliation_strings":["Director's office Privately-owned enterprise \u201cANIGER\u201d,Kyiv,Ukraine"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Director's office Privately-owned enterprise \u201cANIGER\u201d,Kyiv,Ukraine","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079863635","display_name":"Yurii Pylypenko","orcid":"https://orcid.org/0009-0009-8827-8165","observed_orcids":["https://orcid.org/0009-0009-8827-8165"]},"institutions":[{"id":"https://openalex.org/I149851306","display_name":"National Academy of Sciences of Ukraine","ror":"https://ror.org/00je4t102","country_code":"UA","type":"government","lineage":["https://openalex.org/I149851306"]},{"id":"https://openalex.org/I4210099603","display_name":"Institute of Electrodynamics","ror":"https://ror.org/010c2f249","country_code":"UA","type":"facility","lineage":["https://openalex.org/I149851306","https://openalex.org/I4210099603"]}],"countries":["UA"],"is_corresponding":false,"raw_author_name":"Yurii Pylypenko","raw_affiliation_strings":["Institute of Electrodynamics of the National Academy of Sciences of Ukraine,Department of electrical systems automation,Kyiv,Ukraine","Department of electrical systems automation, Institute of Electrodynamics of the National Academy of Sciences of Ukraine, Kyiv, Ukraine"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electrodynamics of the National Academy of Sciences of Ukraine,Department of electrical systems automation,Kyiv,Ukraine","institution_ids":["https://openalex.org/I149851306","https://openalex.org/I4210099603"]},{"raw_affiliation_string":"Department of electrical systems automation, Institute of Electrodynamics of the National Academy of Sciences of Ukraine, Kyiv, Ukraine","institution_ids":["https://openalex.org/I149851306","https://openalex.org/I4210099603"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056025375","display_name":"Dmytro Voitov","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I149851306","display_name":"National Academy of Sciences of Ukraine","ror":"https://ror.org/00je4t102","country_code":"UA","type":"government","lineage":["https://openalex.org/I149851306"]},{"id":"https://openalex.org/I4210099603","display_name":"Institute of Electrodynamics","ror":"https://ror.org/010c2f249","country_code":"UA","type":"facility","lineage":["https://openalex.org/I149851306","https://openalex.org/I4210099603"]}],"countries":["UA"],"is_corresponding":false,"raw_author_name":"Dmytro Voitov","raw_affiliation_strings":["Institute of Electrodynamics of the National Academy of Sciences of Ukraine,Department of electrical systems automation,Kyiv,Ukraine","Department of electrical systems automation, Institute of Electrodynamics of the National Academy of Sciences of Ukraine, Kyiv, Ukraine"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electrodynamics of the National Academy of Sciences of Ukraine,Department of electrical systems automation,Kyiv,Ukraine","institution_ids":["https://openalex.org/I149851306","https://openalex.org/I4210099603"]},{"raw_affiliation_string":"Department of electrical systems automation, Institute of Electrodynamics of the National Academy of Sciences of Ukraine, Kyiv, Ukraine","institution_ids":["https://openalex.org/I149851306","https://openalex.org/I4210099603"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"73","last_page":"77"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ground-fault-location","display_name":"ground fault location","score":0.8029999732971191},{"id":"https://openalex.org/keywords/fault-distance-estimation","display_name":"fault distance estimation","score":0.8809999823570251},{"id":"https://openalex.org/keywords/isolated-neutral","display_name":"isolated neutral","score":0.5519999861717224},{"id":"https://openalex.org/keywords/power-transmission-lines","display_name":"power transmission lines","score":0.6480000019073486},{"id":"https://openalex.org/keywords/phase-current","display_name":"phase current","score":0.6480000019073486},{"id":"https://openalex.org/keywords/fault-resistance","display_name":"fault resistance","score":0.7599999904632568}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7315250039100647},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.7035406827926636},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.6253308653831482},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.5283190608024597},{"id":"https://openalex.org/C48677424","wikidata":"https://www.wikidata.org/wiki/Q6888088","display_name":"Mode (computer interface)","level":2,"score":0.48261532187461853},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.46504533290863037},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.43712717294692993},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.43174585700035095},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.39559242129325867},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39273661375045776},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35261964797973633},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.323476105928421},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.25103992223739624},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.21983957290649414},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17885556817054749},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.1368851363658905},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.12575918436050415},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0643574595451355},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ess57819.2022.9969330","doi":"https://doi.org/10.1109/ess57819.2022.9969330","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ess57819.2022.9969330","pdf_url":null,"source":{"id":"https://openalex.org/S7407087480","display_name":"IEEE International Conference on Energy Smart Systems (ESS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.651199996471405,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W847275268","https://openalex.org/W1007904505","https://openalex.org/W2150180156","https://openalex.org/W2493268089","https://openalex.org/W2902112362","https://openalex.org/W2953958317","https://openalex.org/W3103080777","https://openalex.org/W7030543034"],"related_works":["https://openalex.org/W2000621789","https://openalex.org/W2610758275","https://openalex.org/W2493268089","https://openalex.org/W4396555015","https://openalex.org/W2030544918","https://openalex.org/W4225624538","https://openalex.org/W2547562881","https://openalex.org/W2106953331","https://openalex.org/W3092608970","https://openalex.org/W2607766384"],"abstract_inverted_index":{"In":[0],"this":[1],"paper":[2],"the":[3,44,47,65,69,117,125],"method":[4,70],"to":[5,41,114,116],"determine":[6],"fault":[7,13,118,126],"location":[8,100,127],"in":[9,91],"case":[10,92],"of":[11,24,46,56,64,68,93,96],"ground":[12],"at":[14,43,98,124],"power":[15,102],"line":[16],"with":[17],"isolated":[18],"neutral":[19],"has":[20,71,128],"been":[21,72,129],"proposed.":[22],"Estimation":[23],"fault's":[25,99],"distance":[26,50,115],"is":[27,52],"carried":[28,130],"out":[29],"based":[30],"on":[31,110],"line's":[32,57,103],"operating":[33,58],"mode":[34,59],"parameters":[35,60],"(namely":[36],"phase":[37],"currents":[38],"and":[39,101],"voltages":[40],"ground)":[42],"start":[45],"line.":[48,66],"Fault's":[49],"calculation":[51],"implemented":[53],"using":[54],"vectors":[55],"from":[61],"both":[62],"sides":[63],"Verification":[67],"conducted":[73],"experimentally":[74],"as":[75,77,119,121],"well":[76,120],"via":[78],"math":[79],"modelling.":[80],"Method's":[81],"errors":[82],"were":[83],"caused":[84],"mostly":[85],"by":[86],"small":[87],"currents'":[88],"value":[89,123],"alteration":[90],"fault,":[94],"existence":[95],"resistance":[97,105,122],"load":[104],"change.":[106],"Research":[107],"about":[108],"impact":[109],"method's":[111],"accuracy":[112],"due":[113],"out.":[131]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4312371056","counts_by_year":[],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2023-01-04T00:00:00"}