{"id":"https://openalex.org/W4287846859","doi":"https://doi.org/10.1109/eic51169.2022.9833165","title":"A Comparison of PD Detection Techniques for Complete Assemblies of Air-Insulated Switchgear","display_name":"A Comparison of PD Detection Techniques for Complete Assemblies of Air-Insulated Switchgear","publication_year":2022,"publication_date":"2022-06-19","ids":{"openalex":"https://openalex.org/W4287846859","doi":"https://doi.org/10.1109/eic51169.2022.9833165"},"language":"en","primary_location":{"id":"doi:10.1109/eic51169.2022.9833165","doi":"https://doi.org/10.1109/eic51169.2022.9833165","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eic51169.2022.9833165","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006012508","display_name":"Mathieu Lachance","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mathieu Lachance","raw_affiliation_strings":["OMICRON Electronics Canada, Toronto, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"OMICRON Electronics Canada, Toronto, Canada","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108816621","display_name":"Francis Rosa","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Francis Rosa","raw_affiliation_strings":["Technologies Dual-ADE inc, Sherbrooke, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Technologies Dual-ADE inc, Sherbrooke, Canada","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.9613,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.8515697,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"313","last_page":"317"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.002300000051036477,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.00139999995008111,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/partial-discharge-detection","display_name":"partial discharge detection","score":0.9470000267028809},{"id":"https://openalex.org/keywords/air-insulated-switchgear","display_name":"air-insulated switchgear","score":0.9169999957084656},{"id":"https://openalex.org/keywords/medium-voltage-switchgear","display_name":"medium-voltage switchgear","score":0.8399999737739563},{"id":"https://openalex.org/keywords/metal-clad-switchgear","display_name":"metal-clad switchgear","score":0.8410000205039978},{"id":"https://openalex.org/keywords/metal-enclosed-switchgear","display_name":"metal-enclosed switchgear","score":0.9829999804496765},{"id":"https://openalex.org/keywords/transient-earth-voltage","display_name":"transient earth voltage","score":0.6579999923706055},{"id":"https://openalex.org/keywords/apparent-charge","display_name":"apparent charge","score":0.6919999718666077},{"id":"https://openalex.org/keywords/digital-filtering","display_name":"digital filtering","score":0.718999981880188}],"concepts":[{"id":"https://openalex.org/C93893174","wikidata":"https://www.wikidata.org/wiki/Q1273786","display_name":"Switchgear","level":2,"score":0.947711706161499},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5865212082862854},{"id":"https://openalex.org/C2780202535","wikidata":"https://www.wikidata.org/wiki/Q4524457","display_name":"Wideband","level":2,"score":0.5364561676979065},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.4964001774787903},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.47651779651641846},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.4549512267112732},{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.44435542821884155},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41971996426582336},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.40540459752082825},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3934517204761505},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3481248915195465},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.31914234161376953},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.30387744307518005},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19689148664474487},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18607282638549805},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.09445628523826599}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/eic51169.2022.9833165","doi":"https://doi.org/10.1109/eic51169.2022.9833165","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eic51169.2022.9833165","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1644772056","https://openalex.org/W1969749295","https://openalex.org/W2064979621","https://openalex.org/W2094320239","https://openalex.org/W2116451521","https://openalex.org/W2126362792","https://openalex.org/W2132945360","https://openalex.org/W2134193596","https://openalex.org/W2318672832","https://openalex.org/W3215228226","https://openalex.org/W3216451233","https://openalex.org/W3217604391","https://openalex.org/W4239895683","https://openalex.org/W6666788549","https://openalex.org/W6699380160","https://openalex.org/W7033282364"],"related_works":["https://openalex.org/W4401516533","https://openalex.org/W4405304027","https://openalex.org/W2366881501","https://openalex.org/W4313520893","https://openalex.org/W2115733849","https://openalex.org/W4413556930","https://openalex.org/W2353027427","https://openalex.org/W7126115728","https://openalex.org/W2566464057","https://openalex.org/W2117995063"],"abstract_inverted_index":{"This":[0],"publication":[1],"presents":[2],"a":[3,31,40,53,100,110,125,169],"comparison":[4],"between":[5],"conventional":[6,146,195],"PD":[7,10,14,27,47,79,108,133,153,165,196],"measurements,":[8],"TEV":[9,74,118,158],"detection":[11,15,98,166],"and":[12,38],"ultrasonic":[13,97],"applied":[16,89],"on":[17],"medium-voltage":[18],"air-insulated":[19],"switchgear.":[20,46],"Several":[21],"types":[22],"of":[23,60,113,127,140,150,164],"anomalies":[24],"which":[25,81],"generated":[26,136],"were":[28,49,69,191],"introduced":[29],"in":[30,39,52,121],"15":[32],"kV":[33,42],"rated":[34,43],"metal-clad":[35],"distribution":[36,45],"switchgear":[37],"35":[41],"metal-enclosed":[44],"measurements":[48,68],"then":[50],"performed":[51,70],"factory":[54],"environment":[55],"to":[56,87,90,132,173,177,186],"verify":[57],"the":[58,91,151,156,162,178],"sensitivity":[59,163],"each":[61],"technique":[62],"using":[63,99,194],"commercially":[64],"available":[65],"instruments.":[66],"Additional":[67],"by":[71,145,167],"combining":[72],"stand-alone":[73,157],"sensors":[75,159],"with":[76,109,155],"an":[77],"advance":[78],"instrument,":[80],"allows":[82],"freely":[83],"configurable":[84,170],"digital":[85,171],"filters":[86],"be":[88,174],"acquired":[92],"signals.It":[93],"was":[94,130],"found":[95],"that":[96,135,188],"camera":[101],"is":[102,183],"very":[103],"useful":[104],"at":[105],"localizing":[106],"external":[107],"clear":[111],"line":[112],"sight.":[114],"The":[115,148],"wideband":[116],"handheld":[117],"instrument":[119,154],"used":[120],"those":[122],"experiments":[123],"detected":[124,192],"variety":[126],"defects":[128,190],"but":[129],"limited":[131],"sources":[134],"relatively":[137],"high":[138],"levels":[139],"apparent":[141],"charge,":[142],"as":[143],"measured":[144],"measurements.":[147,197],"combination":[149],"advanced":[152],"greatly":[160],"improved":[161],"allowing":[168],"filter":[172],"tailored":[175],"according":[176],"actual":[179],"test":[180],"environment.":[181],"It":[182],"also":[184],"important":[185],"mention":[187],"all":[189],"when":[193]},"counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2022-07-26T00:00:00"}