{"id":"https://openalex.org/W4285705757","doi":"https://doi.org/10.46855/energy-proceedings-1597","title":"Multi-Scenario Operation Strategy for ESS Based on Dynamic Programming Algorithm","display_name":"Multi-Scenario Operation Strategy for ESS Based on Dynamic Programming Algorithm","publication_year":2020,"publication_date":"2020-02-25","ids":{"openalex":"https://openalex.org/W4285705757","doi":"https://doi.org/10.46855/energy-proceedings-1597"},"language":"en","primary_location":{"id":"doi:10.46855/energy-proceedings-1597","doi":"https://doi.org/10.46855/energy-proceedings-1597","is_oa":true,"landing_page_url":"https://doi.org/10.46855/energy-proceedings-1597","pdf_url":"http://www.energy-proceedings.org/wp-content/uploads/2020/02/139_Paper_0701022916.pdf","source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"},"volume":null,"type":"preprint","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://www.energy-proceedings.org/wp-content/uploads/2020/02/139_Paper_0701022916.pdf","any_repository_has_fulltext":null},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113779780","display_name":"Qiwei Di","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"QIU Di","raw_affiliation_strings":["Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education (Shanghai Jiao Tong University) Minhang District, Shanghai 200240, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education (Shanghai Jiao Tong University) Minhang District, Shanghai 200240, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":null,"display_name":"WANG Haojing","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273203","display_name":"State Grid Shanghai Municipal Electric Power Company (China)","ror":"https://ror.org/05faa4c07","country_code":"CN","type":"company","lineage":["https://openalex.org/I4405273203"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"WANG Haojing","raw_affiliation_strings":["Electric Power Research Institute of State Grid Shanghai Municipal Electric Power Company, Shanghai 200063, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Research Institute of State Grid Shanghai Municipal Electric Power Company, Shanghai 200063, China","institution_ids":["https://openalex.org/I4405273203"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090320758","display_name":"Dong Liu","orcid":"https://orcid.org/0000-0001-6990-2473","observed_orcids":["https://orcid.org/0000-0001-6990-2473"]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"LIU Dong","raw_affiliation_strings":["Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education (Shanghai Jiao Tong University) Minhang District, Shanghai 200240, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education (Shanghai Jiao Tong University) Minhang District, Shanghai 200240, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":null,"display_name":"ZHANG Yu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273203","display_name":"State Grid Shanghai Municipal Electric Power Company (China)","ror":"https://ror.org/05faa4c07","country_code":"CN","type":"company","lineage":["https://openalex.org/I4405273203"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"ZHANG Yu","raw_affiliation_strings":["Electric Power Research Institute of State Grid Shanghai Municipal Electric Power Company, Shanghai 200063, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Research Institute of State Grid Shanghai Municipal Electric Power Company, Shanghai 200063, China","institution_ids":["https://openalex.org/I4405273203"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101428760","display_name":"Chen Fang","orcid":"https://orcid.org/0000-0002-8559-0112","observed_orcids":["https://orcid.org/0000-0002-8559-0112"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"FANG Chen","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"XU Qin","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273203","display_name":"State Grid Shanghai Municipal Electric Power Company (China)","ror":"https://ror.org/05faa4c07","country_code":"CN","type":"company","lineage":["https://openalex.org/I4405273203"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"XU Qin","raw_affiliation_strings":["Electric Power Research Institute of State Grid Shanghai Municipal Electric Power Company, Shanghai 200063, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Research Institute of State Grid Shanghai Municipal Electric Power Company, Shanghai 200063, China","institution_ids":["https://openalex.org/I4405273203"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.6801999807357788,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.6801999807357788,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.13840000331401825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.11230000108480453,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-storage-systems","display_name":"energy storage systems","score":0.9359999895095825},{"id":"https://openalex.org/keywords/optimal-control-policy","display_name":"optimal control policy","score":0.8320000171661377},{"id":"https://openalex.org/keywords/peak-shaving","display_name":"peak shaving","score":0.6859999895095825},{"id":"https://openalex.org/keywords/dynamic-programming","display_name":"dynamic programming","score":0.8700000047683716}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.648163914680481},{"id":"https://openalex.org/C37404715","wikidata":"https://www.wikidata.org/wiki/Q380679","display_name":"Dynamic programming","level":2,"score":0.6177011132240295},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.4925168454647064},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.35757631063461304},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.14420461654663086}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.46855/energy-proceedings-1597","doi":"https://doi.org/10.46855/energy-proceedings-1597","is_oa":true,"landing_page_url":"https://doi.org/10.46855/energy-proceedings-1597","pdf_url":"http://www.energy-proceedings.org/wp-content/uploads/2020/02/139_Paper_0701022916.pdf","source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"}],"best_oa_location":{"id":"doi:10.46855/energy-proceedings-1597","doi":"https://doi.org/10.46855/energy-proceedings-1597","is_oa":true,"landing_page_url":"https://doi.org/10.46855/energy-proceedings-1597","pdf_url":"http://www.energy-proceedings.org/wp-content/uploads/2020/02/139_Paper_0701022916.pdf","source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9853000044822693},{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.8970999717712402}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4285705757.pdf","grobid_xml":"https://content.openalex.org/works/W4285705757.grobid-xml"},"referenced_works_count":5,"referenced_works":["https://openalex.org/W1978242968","https://openalex.org/W2105302512","https://openalex.org/W2146531934","https://openalex.org/W2390984522","https://openalex.org/W4200190646"],"related_works":["https://openalex.org/W2887802884","https://openalex.org/W4281806819","https://openalex.org/W4223965176","https://openalex.org/W4386248601","https://openalex.org/W4389988811","https://openalex.org/W2470723161","https://openalex.org/W2996550708","https://openalex.org/W4320001926","https://openalex.org/W2792445923","https://openalex.org/W4409744680"],"abstract_inverted_index":{"The":[0],"multi-scenario":[1,43],"operation":[2,24,44,108],"of":[3,57,102],"the":[4,19,23,27,40,53,68,70,76,92,98,107,114],"energy":[5],"storage":[6],"system":[7,116],"(ESS)":[8],"improves":[9],"its":[10],"economy":[11],"and":[12,30,105],"makes":[13],"it":[14],"more":[15],"widely":[16],"used":[17,81],"in":[18,47,90,113],"power":[20,56,61,103,115],"grid.By":[21],"categorizing":[22],"scenario":[25],"into":[26],"periodic":[28],"running":[29,32],"triggering":[31],"scenarios,":[33],"a":[34,59,87],"novel":[35],"optimal":[36],"control":[37,94],"strategy":[38,95],"for":[39],"ESS":[41],"under":[42],"is":[45,65,74,80],"presented":[46],"this":[48,84],"paper.In":[49],"order":[50],"to":[51,82],"evaluate":[52],"maximum":[54],"input/output":[55],"ESS,":[58],"new":[60],"capability":[62],"index":[63],"(PCI)":[64],"defined.Base":[66],"on":[67,86],"PCI,":[69],"peak-shaving":[71],"optimization":[72],"model":[73],"built.Then":[75],"dynamic":[77],"programming":[78],"algorithm":[79],"solve":[83],"model.Evaluated":[85],"10kV":[88],"substation":[89],"Shanghai,":[91],"proposed":[93],"effectively":[96],"alleviates":[97],"peak":[99],"load":[100],"pressure":[101],"supply":[104],"responds":[106],"commands":[109],"by":[110],"different":[111],"roles":[112],"efficiently.":[117]},"counts_by_year":[],"updated_date":"2026-11-09T13:22:03.289127","created_date":"2022-07-18T00:00:00"}
