{"id":"https://openalex.org/W4283811571","doi":"https://doi.org/10.37394/23201.2022.21.17","title":"Closed Loop Modified SEPIC Converter for Photovoltaic System","display_name":"Closed Loop Modified SEPIC Converter for Photovoltaic System","publication_year":2022,"publication_date":"2022-07-05","ids":{"openalex":"https://openalex.org/W4283811571","doi":"https://doi.org/10.37394/23201.2022.21.17"},"language":"en","primary_location":{"id":"doi:10.37394/23201.2022.21.17","doi":"https://doi.org/10.37394/23201.2022.21.17","is_oa":true,"landing_page_url":"https://doi.org/10.37394/23201.2022.21.17","pdf_url":null,"source":{"id":"https://openalex.org/S2764701073","display_name":"WSEAS Transactions on Circuits and Systems archive","issn_l":"1109-2734","issn":["1109-2734","2224-266X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","poland-20","russia-white-list-4"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.37394/23201.2022.21.17","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064388141","display_name":"Abdel-Karim Daud","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I37417134","display_name":"Palestine Polytechnic University","ror":"https://ror.org/03wwspn40","country_code":"PS","type":"education","lineage":["https://openalex.org/I37417134"]}],"countries":["PS"],"is_corresponding":false,"raw_author_name":"Abdel-Karim Daud","raw_affiliation_strings":["Electrical Engineering Department Palestine Polytechnic University West Bank- Hebron, P.O.Box 198 PALESTINE","PALESTINE"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department Palestine Polytechnic University West Bank- Hebron, P.O.Box 198 PALESTINE","institution_ids":["https://openalex.org/I37417134"]},{"raw_affiliation_string":"PALESTINE","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5030784353","display_name":"Sameer Hanna Khader","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I37417134","display_name":"Palestine Polytechnic University","ror":"https://ror.org/03wwspn40","country_code":"PS","type":"education","lineage":["https://openalex.org/I37417134"]}],"countries":["PS"],"is_corresponding":false,"raw_author_name":"Sameer Khader","raw_affiliation_strings":["Electrical Engineering Department Palestine Polytechnic University West Bank- Hebron, P.O.Box 198 PALESTINE","PALESTINE"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department Palestine Polytechnic University West Bank- Hebron, P.O.Box 198 PALESTINE","institution_ids":["https://openalex.org/I37417134"]},{"raw_affiliation_string":"PALESTINE","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I37417134"],"apc_list":null,"apc_paid":null,"fwci":0.4083,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.47621456,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":95},"biblio":{"volume":"21","issue":null,"first_page":"161","last_page":"167"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.002199999988079071,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/modified-sepic-converter","display_name":"modified SEPIC converter","score":0.9190000295639038},{"id":"https://openalex.org/keywords/photovoltaic-systems","display_name":"photovoltaic systems","score":0.8790000081062317},{"id":"https://openalex.org/keywords/closed-loop-feedback-control","display_name":"closed-loop feedback control","score":0.8479999899864197},{"id":"https://openalex.org/keywords/pid-controller","display_name":"PID controller","score":0.9900000095367432},{"id":"https://openalex.org/keywords/output-voltage-regulation","display_name":"output voltage regulation","score":0.8140000104904175},{"id":"https://openalex.org/keywords/maximum-power-point","display_name":"maximum power point","score":0.7260000109672546},{"id":"https://openalex.org/keywords/converter-efficiency","display_name":"converter efficiency","score":0.6869999766349792},{"id":"https://openalex.org/keywords/robustness-to-load-variation","display_name":"load variation robustness","score":0.7080000042915344}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7397607564926147},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6939594745635986},{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.6556906700134277},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5782591104507446},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.4887799918651581},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.4867730140686035},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.45099708437919617},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43701034784317017},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.41930052638053894},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28493672609329224},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14751535654067993},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.1386343538761139},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.13107523322105408},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.079363614320755},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.37394/23201.2022.21.17","doi":"https://doi.org/10.37394/23201.2022.21.17","is_oa":true,"landing_page_url":"https://doi.org/10.37394/23201.2022.21.17","pdf_url":null,"source":{"id":"https://openalex.org/S2764701073","display_name":"WSEAS Transactions on Circuits and Systems archive","issn_l":"1109-2734","issn":["1109-2734","2224-266X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","poland-20","russia-white-list-4"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.37394/23201.2022.21.17","doi":"https://doi.org/10.37394/23201.2022.21.17","is_oa":true,"landing_page_url":"https://doi.org/10.37394/23201.2022.21.17","pdf_url":null,"source":{"id":"https://openalex.org/S2764701073","display_name":"WSEAS Transactions on Circuits and Systems archive","issn_l":"1109-2734","issn":["1109-2734","2224-266X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","poland-20","russia-white-list-4"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W152381989","https://openalex.org/W1502514359","https://openalex.org/W1982169051","https://openalex.org/W1983417689","https://openalex.org/W2028309847","https://openalex.org/W2095679451","https://openalex.org/W2121097709","https://openalex.org/W2160112143","https://openalex.org/W2184664748","https://openalex.org/W2345292287","https://openalex.org/W2772132839","https://openalex.org/W2792248083","https://openalex.org/W2900172659","https://openalex.org/W3158716820"],"related_works":["https://openalex.org/W7204970809","https://openalex.org/W4385241780","https://openalex.org/W4362578162","https://openalex.org/W3194883646","https://openalex.org/W6911776322","https://openalex.org/W4315629457","https://openalex.org/W1985086804","https://openalex.org/W7120412078","https://openalex.org/W4403937520","https://openalex.org/W4289768507"],"abstract_inverted_index":{"The":[0,16,35,85,118],"high":[1,24,31],"static":[2],"gain":[3],"modified":[4],"single":[5],"ended":[6],"primary":[7],"coil":[8],"(MSEPIC)":[9],"converter":[10,18,39,59],"is":[11,40,55,68,88,99],"presented":[12,41],"in":[13,92],"this":[14],"paper.":[15],"proposed":[17,86],"presents":[19,113],"low":[20,27],"switch":[21],"voltage":[22,29,33,76,127],"and":[23,30,42,77,90,94,135,142],"efficiency":[25,114],"for":[26,57],"input":[28,75],"output":[32,63,126],"applications.":[34],"configuration":[36],"of":[37],"MSEPIC":[38,58],"analyzed.":[43],"Closed":[44],"loop":[45],"feedback":[46],"control":[47],"with":[48,70,101],"PID":[49,119],"controller":[50,120],"based":[51],"on":[52,80],"triggering":[53],"system":[54],"developed":[56,100],"to":[60,109,116],"maintain":[61],"constant":[62],"voltage.":[64],"Furthermore,":[65,133],"the":[66,74,81,125,130],"model":[67,87,98],"integrated":[69],"Photovoltaic":[71],"generator":[72],"where":[73],"current":[78],"depend":[79],"solar":[82],"irradiation":[83],"rates.":[84],"analyzed":[89],"simulated":[91],"Matlab/Simulink":[93],"m-file":[95],"code.":[96],"Simulation":[97],"a":[102],"maximum":[103],"power":[104],"at":[105],"full":[106],"sun":[107],"equal":[108,115],"315":[110],"W,":[111],"which":[112],"99.03%.":[117],"works":[121],"as":[122,124],"intended,":[123],"can":[128],"approach":[129],"expected":[131],"value.":[132],"performance":[134],"robustness":[136],"are":[137],"tested":[138],"by":[139],"load":[140],"variations":[141],"set":[143],"point":[144],"variations.":[145]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2022-07-06T00:00:00"}
