{"id":"https://openalex.org/W4250008563","doi":"https://doi.org/10.1515/energyo.0034.00417","title":"Distance Relaying with Power Swing Detection based on Voltage and Reactive Power Sensitivity","display_name":"Distance Relaying with Power Swing Detection based on Voltage and Reactive Power Sensitivity","publication_year":2018,"publication_date":"2018-03-01","ids":{"openalex":"https://openalex.org/W4250008563","doi":"https://doi.org/10.1515/energyo.0034.00417"},"language":"en","primary_location":{"id":"doi:10.1515/energyo.0034.00417","doi":"https://doi.org/10.1515/energyo.0034.00417","is_oa":false,"landing_page_url":"https://doi.org/10.1515/energyo.0034.00417","pdf_url":null,"source":{"id":"https://openalex.org/S4363604221","display_name":"energyo","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ENERGYO","raw_type":"dataset"},"volume":null,"type":"dataset","is_traditional":false,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075253020","display_name":"Ujjaval J. Patel","orcid":"https://orcid.org/0000-0003-2631-4107","observed_orcids":["https://orcid.org/0000-0003-2631-4107"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ujjaval J. Patel","raw_affiliation_strings":["Department of Electrical Engineering, Vadodara Institute of Engineering, Vadodara, Gujarat, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Vadodara Institute of Engineering, Vadodara, Gujarat, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035288948","display_name":"Nilesh Chothani","orcid":"https://orcid.org/0000-0002-9936-1687","observed_orcids":["https://orcid.org/0000-0002-9936-1687"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Nilesh G. Chothani","raw_affiliation_strings":["Department of Electrical Engineering, A D Patel Institute of Technology, behind GIDC Vitthal, Udyognagar New V.V. Nagar, Anand, Gujarat 388121, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, A D Patel Institute of Technology, behind GIDC Vitthal, Udyognagar New V.V. Nagar, Anand, Gujarat 388121, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021559525","display_name":"Praghnesh J. Bhatt","orcid":"https://orcid.org/0000-0002-0262-9991","observed_orcids":["https://orcid.org/0000-0002-0262-9991"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Praghnesh J. Bhatt","raw_affiliation_strings":["Department of Electrical Engineering, C. S. Patel Institute of Technology, Anand, Gujarat, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, C. S. Patel Institute of Technology, Anand, Gujarat, India","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5035288948"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/distance-relaying","display_name":"distance relaying","score":0.7919999957084656},{"id":"https://openalex.org/keywords/power-swing-detection","display_name":"power swing detection","score":0.8669999837875366},{"id":"https://openalex.org/keywords/fault-discrimination","display_name":"fault discrimination","score":0.6980000138282776},{"id":"https://openalex.org/keywords/rate-of-change-of-voltage","display_name":"rate of change of voltage","score":0.9150000214576721},{"id":"https://openalex.org/keywords/synchronous-generator","display_name":"synchronous generator","score":0.5230000019073486},{"id":"https://openalex.org/keywords/symmetrical-and-asymmetrical-faults","display_name":"symmetrical and asymmetrical faults","score":0.8479999899864197},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.4490000009536743}],"concepts":[{"id":"https://openalex.org/C65655974","wikidata":"https://www.wikidata.org/wiki/Q14867674","display_name":"Swing","level":2,"score":0.7398709058761597},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.7256218194961548},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6474090814590454},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5800005793571472},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5044692754745483},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.46983668208122253},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37403905391693115},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23917856812477112},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.23476624488830566},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2039811611175537},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.117743581533432},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1515/energyo.0034.00417","doi":"https://doi.org/10.1515/energyo.0034.00417","is_oa":false,"landing_page_url":"https://doi.org/10.1515/energyo.0034.00417","pdf_url":null,"source":{"id":"https://openalex.org/S4363604221","display_name":"energyo","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ENERGYO","raw_type":"dataset"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6700000166893005,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.4000000059604645,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1638570474","https://openalex.org/W2067300607","https://openalex.org/W2934437426","https://openalex.org/W2541870022","https://openalex.org/W1917317747","https://openalex.org/W3127887781","https://openalex.org/W2964823235","https://openalex.org/W3179424337","https://openalex.org/W3118786442","https://openalex.org/W2124765774"],"abstract_inverted_index":{"Sudden":[0],"changes":[1],"in":[2,16,41,46,99,109,139],"loading":[3],"or":[4],"configuration":[5],"of":[6,20,53,73,75,86,95,117,126,141,154],"an":[7,17],"electrical":[8],"network":[9,48],"causes":[10],"power":[11,38,47,68,79,96,111,149,173],"swing":[12,39,69,97,150,174],"which":[13],"may":[14],"result":[15],"unwanted":[18],"tripping":[19,116,138],"the":[21,63,87,133,152,155,159,166],"distance":[22,54,134],"relay.":[23,55],"Hence,":[24],"it":[25],"becomes":[26],"utmost":[27],"necessary":[28],"to":[29,43,50,113,121,164],"rapidly":[30],"and":[31,37,67,77,123,145,168],"reliably":[32],"discriminate":[33],"between":[34,65],"actual":[35],"fault":[36,66,122,143,170],"conditions":[40,98,144],"order":[42],"prevent":[44],"instability":[45],"due":[49,120],"mal":[51],"operation":[52],"This":[56],"paper":[57],"proposes":[58],"a":[59],"novel":[60],"method":[61],"for":[62,103,148],"discrimination":[64],"based":[70],"on":[71],"rate":[72],"change":[74,108],"voltage":[76],"reactive":[78],"measured":[80],"at":[81],"relay":[82,135],"location.":[83],"The":[84],"effectiveness":[85],"proposed":[88,156,160],"algorithm":[89],"is":[90,130],"evaluated":[91],"by":[92],"simulating":[93],"series":[94],"PSCAD/EMTDC":[100],"\u00ae":[101],"software":[102],"different":[104,142],"disturbances":[105],"such":[106],"as":[107],"mechanical":[110],"input":[112],"synchronous":[114],"generator,":[115],"parallel":[118],"line":[119],"sudden":[124],"application":[125],"heavy":[127],"load.":[128],"It":[129],"revealed":[131],"that":[132],"gives":[136],"successful":[137],"case":[140],"remains":[146],"inoperative":[147],"with":[151],"implementation":[153],"algorithm.":[157],"Moreover,":[158],"scheme":[161],"has":[162],"ability":[163],"distinguish":[165],"symmetrical":[167],"asymmetrical":[169],"occurrence":[171],"during":[172],"condition.":[175]},"counts_by_year":[],"updated_date":"2026-09-22T06:50:58.402377","created_date":"2022-05-12T00:00:00"}
