{"id":"https://openalex.org/W4240635722","doi":"https://doi.org/10.1109/ee.1943.6435850","title":"Overvoltage protection of current-transformer secondary windings and associated circuits","display_name":"Overvoltage protection of current-transformer secondary windings and associated circuits","publication_year":1943,"publication_date":"1943-07-01","ids":{"openalex":"https://openalex.org/W4240635722","doi":"https://doi.org/10.1109/ee.1943.6435850"},"language":"en","primary_location":{"id":"doi:10.1109/ee.1943.6435850","doi":"https://doi.org/10.1109/ee.1943.6435850","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ee.1943.6435850","pdf_url":null,"source":{"id":"https://openalex.org/S4210187838","display_name":"Electrical Engineering","issn_l":"0095-9197","issn":["0095-9197","2376-7804"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrical Engineering","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040667436","display_name":"Richard H. Kaufmann","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1332737386","display_name":"General Electric (United States)","ror":"https://ror.org/013msgt25","country_code":"US","type":"company","lineage":["https://openalex.org/I1332737386"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"R. H. Kaufmann","raw_affiliation_strings":["General Electric Company, Schenectady, N. Y"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"General Electric Company, Schenectady, N. Y","institution_ids":["https://openalex.org/I1332737386"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038431190","display_name":"G. Camilli","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1332737386","display_name":"General Electric (United States)","ror":"https://ror.org/013msgt25","country_code":"US","type":"company","lineage":["https://openalex.org/I1332737386"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"G. Camilli","raw_affiliation_strings":["General Electric Company, Pittsfield, Mass"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"General Electric Company, Pittsfield, Mass","institution_ids":["https://openalex.org/I1332737386"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I1332737386"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"62","issue":"7","first_page":"467","last_page":"472"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.6420999765396118,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.6420999765396118,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.20200000703334808,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.060100000351667404,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current-transformers","display_name":"current transformers","score":0.578000009059906},{"id":"https://openalex.org/keywords/overvoltage-protection","display_name":"overvoltage protection","score":0.9760000109672546},{"id":"https://openalex.org/keywords/switching-transients","display_name":"switching transients","score":0.9229999780654907},{"id":"https://openalex.org/keywords/lumped-capacitance","display_name":"lumped capacitance","score":0.8820000290870667},{"id":"https://openalex.org/keywords/insulation-damage","display_name":"insulation damage","score":0.5640000104904175},{"id":"https://openalex.org/keywords/ratio-error","display_name":"ratio error","score":0.5960000157356262}],"concepts":[{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.8718370199203491},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.7207632660865784},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.6479777097702026},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6435850858688354},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.589312732219696},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5548539757728577},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.5426117181777954},{"id":"https://openalex.org/C204106720","wikidata":"https://www.wikidata.org/wiki/Q15856134","display_name":"Current limiting","level":3,"score":0.5294855237007141},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4628623425960541},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.4605751037597656},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.4578063189983368},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.435861200094223},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.4195959270000458},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.4120328724384308}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ee.1943.6435850","doi":"https://doi.org/10.1109/ee.1943.6435850","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ee.1943.6435850","pdf_url":null,"source":{"id":"https://openalex.org/S4210187838","display_name":"Electrical Engineering","issn_l":"0095-9197","issn":["0095-9197","2376-7804"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrical Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2799412145","https://openalex.org/W2374625911","https://openalex.org/W2390204793","https://openalex.org/W7217838727","https://openalex.org/W1642200726","https://openalex.org/W3047798459","https://openalex.org/W2347589301","https://openalex.org/W4205666278","https://openalex.org/W2355112406","https://openalex.org/W2364716371"],"abstract_inverted_index":{"It":[0],"has":[1],"long":[2],"been":[3],"recognized":[4],"that":[5,25],"excessive":[6],"potentials":[7],"may":[8,31,102,115,123],"be":[9,32,103,107,117],"developed":[10],"in":[11,125,192,196],"current-transformer":[12,99,149,156,179],"secondary":[13,74,157],"windings":[14],"under":[15],"unusual":[16],"conditions,":[17,85],"such":[18],"as":[19,34,175,177],"open":[20],"circuits.":[21],"Recent":[22],"experience":[23],"discloses":[24],"dangerous":[26],"overvoltages":[27],"(several":[28],"thousand":[29],"volts)":[30],"produced":[33],"a":[35,78,142],"result":[36,191],"of":[37,54,72,81,128,135,141],"normal":[38,112,198],"switching":[39,60],"operations":[40],"on":[41],"circuits":[42],"containing":[43],"lumped":[44],"capacitance.":[45],"A":[46],"simple":[47],"procedure":[48],"for":[49,58,148],"circuit":[50,100],"analysis":[51],"and":[52,90,168,170,190],"evaluation":[53],"approximate":[55],"voltage":[56,75],"magnitude":[57],"the":[59,94,126,133,197],"transient":[61],"case":[62],"is":[63,88,151,166],"reported.":[64],"For":[65],"easy":[66],"reference,":[67],"there":[68],"are":[69,159,183],"included":[70],"tables":[71],"calculated":[73],"magnitudes":[76],"covering":[77],"broad":[79],"range":[80],"application.":[82],"Under":[83],"certain":[84],"overvoltage":[86,144],"protection":[87,150],"desirable":[89],"important.":[91],"Aside":[92],"from":[93],"potential":[95],"hazard":[96],"to":[97,161,173],"life,":[98],"insulation":[101],"damaged,":[104],"yet":[105,120],"not":[106,116,185],"evident":[108],"immediately.":[109],"Performance":[110],"at":[111],"rated":[113],"current":[114,200],"noticeably":[118],"impaired,":[119],"serious":[121],"failure":[122],"occur":[124],"presence":[127],"fault-current":[129],"flow,":[130],"thus":[131],"nullifying":[132],"action":[134],"current-actuated":[136],"protective":[137],"relays.":[138],"The":[139,164,181],"characteristics":[140,182],"new":[143,178],"protector":[145,165],"expressly":[146],"designed":[147],"presented.":[152],"With":[153],"this":[154],"device":[155],"voltages":[158],"limited":[160],"moderate":[162],"values.":[163],"small":[167],"compact,.":[169],"easily":[171],"applied":[172],"existing":[174],"well":[176],"installations.":[180],"permanent,":[184],"affected":[186],"by":[187],"repetitive":[188],"operation,":[189],"negligible":[193],"ratio":[194],"error":[195],"operating":[199],"range.":[201]},"counts_by_year":[],"updated_date":"2026-09-26T08:19:03.415552","created_date":"2022-05-12T00:00:00"}
