{"id":"https://openalex.org/W4232178308","doi":"https://doi.org/10.1115/gt2010-22432","title":"Experimental Investigation of Conjugate Heat Transfer in a Rib-Roughened Trailing Edge Channel With Crossing-Jets","display_name":"Experimental Investigation of Conjugate Heat Transfer in a Rib-Roughened Trailing Edge Channel With Crossing-Jets","publication_year":2010,"publication_date":"2010-10-10","ids":{"openalex":"https://openalex.org/W4232178308","doi":"https://doi.org/10.1115/gt2010-22432"},"language":"en","primary_location":{"id":"doi:10.1115/gt2010-22432","doi":"https://doi.org/10.1115/gt2010-22432","is_oa":false,"landing_page_url":"https://doi.org/10.1115/gt2010-22432","pdf_url":null,"source":{"id":"https://openalex.org/S4306503524","display_name":"ASME Turbo Expo: Turbomachinery Technical Conference and Exposition (GT)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Volume 4: Heat Transfer, Parts A and B","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070538204","display_name":"Filippo Coletti","orcid":"https://orcid.org/0000-0001-5344-2476","observed_orcids":["https://orcid.org/0000-0001-5344-2476"]},"institutions":[{"id":"https://openalex.org/I149208984","display_name":"Von Karman Institute for Fluid Dynamics","ror":"https://ror.org/01r4bn552","country_code":"BE","type":"nonprofit","lineage":["https://openalex.org/I149208984"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Filippo Coletti","raw_affiliation_strings":["von Karman Institute for Fluid Dynamics, Rhode-St-Gene`se, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"von Karman Institute for Fluid Dynamics, Rhode-St-Gene`se, Belgium","institution_ids":["https://openalex.org/I149208984"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031811882","display_name":"Manfredi Scialanga","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I149208984","display_name":"Von Karman Institute for Fluid Dynamics","ror":"https://ror.org/01r4bn552","country_code":"BE","type":"nonprofit","lineage":["https://openalex.org/I149208984"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Manfredi Scialanga","raw_affiliation_strings":["von Karman Institute for Fluid Dynamics, Rhode-St-Gene`se, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"von Karman Institute for Fluid Dynamics, Rhode-St-Gene`se, Belgium","institution_ids":["https://openalex.org/I149208984"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5036795326","display_name":"Tony Arts","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I149208984","display_name":"Von Karman Institute for Fluid Dynamics","ror":"https://ror.org/01r4bn552","country_code":"BE","type":"nonprofit","lineage":["https://openalex.org/I149208984"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Tony Arts","raw_affiliation_strings":["von Karman Institute for Fluid Dynamics, Rhode-St-Gene`se, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"von Karman Institute for Fluid Dynamics, Rhode-St-Gene`se, Belgium","institution_ids":["https://openalex.org/I149208984"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I149208984"],"apc_list":null,"apc_paid":null,"fwci":1.0666,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.82166302,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"173","last_page":"184"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":0.9384999871253967,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":0.9384999871253967,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10944","display_name":"Turbomachinery Performance and Optimization","score":0.049400001764297485,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12567","display_name":"Heat transfer and supercritical fluids","score":0.006099999882280827,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/conjugate-heat-transfer","display_name":"conjugate heat transfer","score":1.0},{"id":"https://openalex.org/keywords/turbine-blade-cooling","display_name":"turbine blade cooling","score":0.9139999747276306},{"id":"https://openalex.org/keywords/solid-fluid-thermal-conductivity-ratio","display_name":"solid-fluid thermal conductivity ratio","score":0.7710000276565552},{"id":"https://openalex.org/keywords/uniform-heat-flux","display_name":"constant heat flux","score":0.6859999895095825},{"id":"https://openalex.org/keywords/nusselt-number-distribution","display_name":"Nusselt number distribution","score":0.9070000052452087},{"id":"https://openalex.org/keywords/temperature-distribution","display_name":"temperature distribution","score":0.6610000133514404},{"id":"https://openalex.org/keywords/infrared-thermography","display_name":"infrared thermography","score":0.8270000219345093},{"id":"https://openalex.org/keywords/finite-element-analysis","display_name":"finite element analysis","score":0.5699999928474426},{"id":"https://openalex.org/keywords/convective-heat-transfer","display_name":"convective heat transfer","score":0.5379999876022339}],"concepts":[{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.6916161775588989},{"id":"https://openalex.org/C130230704","wikidata":"https://www.wikidata.org/wiki/Q898280","display_name":"Nusselt number","level":4,"score":0.6748949289321899},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6608128547668457},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.6286596655845642},{"id":"https://openalex.org/C159188206","wikidata":"https://www.wikidata.org/wiki/Q1478382","display_name":"Heat flux","level":3,"score":0.5761700868606567},{"id":"https://openalex.org/C28317120","wikidata":"https://www.wikidata.org/wiki/Q975211","display_name":"Trailing edge","level":2,"score":0.554269015789032},{"id":"https://openalex.org/C172100665","wikidata":"https://www.wikidata.org/wiki/Q7465774","display_name":"Thermal conduction","level":2,"score":0.5388389229774475},{"id":"https://openalex.org/C182748727","wikidata":"https://www.wikidata.org/wiki/Q178932","display_name":"Reynolds number","level":3,"score":0.5158090591430664},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.44727638363838196},{"id":"https://openalex.org/C2779570065","wikidata":"https://www.wikidata.org/wiki/Q1754137","display_name":"Leading edge","level":2,"score":0.428976833820343},{"id":"https://openalex.org/C97346530","wikidata":"https://www.wikidata.org/wiki/Q487005","display_name":"Thermal conductivity","level":2,"score":0.428627610206604},{"id":"https://openalex.org/C2779222261","wikidata":"https://www.wikidata.org/wiki/Q624587","display_name":"Thermography","level":3,"score":0.42739251255989075},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.24514272809028625},{"id":"https://openalex.org/C196558001","wikidata":"https://www.wikidata.org/wiki/Q190132","display_name":"Turbulence","level":2,"score":0.23467546701431274},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.19052112102508545},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.18540427088737488},{"id":"https://openalex.org/C158355884","wikidata":"https://www.wikidata.org/wiki/Q11388","display_name":"Infrared","level":2,"score":0.14546161890029907}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1115/gt2010-22432","doi":"https://doi.org/10.1115/gt2010-22432","is_oa":false,"landing_page_url":"https://doi.org/10.1115/gt2010-22432","pdf_url":null,"source":{"id":"https://openalex.org/S4306503524","display_name":"ASME Turbo Expo: Turbomachinery Technical Conference and Exposition (GT)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Volume 4: Heat Transfer, Parts A and B","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W292819770","https://openalex.org/W2013057249","https://openalex.org/W1983748521","https://openalex.org/W2008806854","https://openalex.org/W2020734772","https://openalex.org/W2067157911","https://openalex.org/W2102722055","https://openalex.org/W3200581514","https://openalex.org/W3120157785","https://openalex.org/W2970110859"],"abstract_inverted_index":{"The":[0,25,43,62,93,135],"present":[1],"contribution":[2],"is":[3,28,54,83,147],"devoted":[4],"to":[5,108],"the":[6,10,22,48,51,60,66,71,74,86,90,121,138,141,144,158,161],"experimental":[7],"study":[8],"of":[9,50,64,89,114,128,137],"conjugate":[11],"heat":[12,81],"transfer":[13],"in":[14],"a":[15,31],"turbine":[16],"blade":[17],"cooling":[18,26],"cavity":[19],"located":[20],"near":[21],"trailing":[23],"edge.":[24],"scheme":[27],"characterized":[29],"by":[30,126,149,157],"trapezoidal":[32],"cross-section,":[33],"one":[34],"rib-roughened":[35,91,122],"wall":[36,123,142],"and":[37,117,131],"slots":[38],"along":[39,85],"two":[40],"opposite":[41],"walls.":[42],"Reynolds":[44],"number,":[45],"defined":[46],"at":[47,56],"inlet":[49],"test":[52],"section,":[53],"set":[55],"67500":[57],"for":[58],"all":[59,65],"experiments.":[61],"values":[63],"important":[67],"non-dimensional":[68,115],"parameters":[69],"characterizing":[70],"experiment,":[72],"including":[73],"solid-to-fluid":[75],"conductivity":[76],"ratio,":[77],"are":[78,95,124],"engine-representative.":[79],"Uniform":[80],"flux":[82],"imposed":[84],"outer":[87],"side":[88],"wall.":[92],"measurements":[94],"performed":[96],"using":[97],"three":[98],"different":[99],"ribbed":[100],"walls,":[101],"with":[102,151],"thermal":[103,145],"conductivities":[104],"ranging":[105],"from":[106],"1":[107],"18":[109],"Wm\u22121K\u22121.":[110],"Highly":[111],"resolved":[112],"distributions":[113],"temperature":[116],"Nusselt":[118],"number":[119],"over":[120],"obtained":[125],"means":[127],"infrared":[129],"thermography":[130],"finite":[132],"element":[133],"analysis.":[134],"impact":[136],"conduction":[139],"through":[140],"on":[143,160],"performance":[146],"demonstrated":[148],"comparison":[150],"purely":[152],"convective":[153],"results,":[154],"previously":[155],"published":[156],"authors":[159],"same":[162],"configuration.":[163]},"counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-02T09:45:03.842371","created_date":"2022-05-12T00:00:00"}