{"id":"https://openalex.org/W4230056885","doi":"https://doi.org/10.36227/techrxiv.12991445.v1","title":"2","display_name":"2","alternate_titles":[],"publication_year":2020,"publication_date":"2020-09-27","ids":{"openalex":"https://openalex.org/W4230056885","doi":"https://doi.org/10.36227/techrxiv.12991445.v1"},"language":"en","primary_location":{"id":"doi:10.36227/techrxiv.12991445.v1","doi":"https://doi.org/10.36227/techrxiv.12991445.v1","is_oa":true,"landing_page_url":"https://doi.org/10.36227/techrxiv.12991445.v1","pdf_url":"https://www.techrxiv.org/articles/preprint/Asymmetrical_ZVS-PWM_Switched-Capacitor_Based_Half-Bridge_DC-DC_Converter_With_Switch_Peak_Voltage_of_Vin_2/12991445/files/24752006.pdf","source":null,"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"},"parent_works":[],"lineage":["https://openalex.org/W4230056885"],"child_works_count":0,"type":"preprint","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://www.techrxiv.org/articles/preprint/Asymmetrical_ZVS-PWM_Switched-Capacitor_Based_Half-Bridge_DC-DC_Converter_With_Switch_Peak_Voltage_of_Vin_2/12991445/files/24752006.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039973794","display_name":"Ang\u00e9lica Paula Ca\u00fas","orcid":"https://orcid.org/0000-0002-2696-0056","observed_orcids":["https://orcid.org/0000-0002-2696-0056"]},"institutions":[{"id":"https://openalex.org/I4104125","display_name":"Universidade Federal de Santa Catarina","ror":"https://ror.org/041akq887","country_code":"BR","type":"education","lineage":["https://openalex.org/I4104125"]}],"countries":["BR"],"is_corresponding":true,"raw_author_name":"Angelica Paula Caus","raw_affiliation_strings":["Universidade Federal de Santa Catarina"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universidade Federal de Santa Catarina","institution_ids":["https://openalex.org/I4104125"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Guilherme Martins Leandro","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Guilherme Martins Leandro","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5014942516","display_name":"Ivo Barbi","orcid":"https://orcid.org/0000-0002-0917-2779","observed_orcids":["https://orcid.org/0000-0002-0917-2779"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ivo Barbi","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-0917-2779","affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5039973794"],"corresponding_institution_ids":["https://openalex.org/I4104125"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/zero-voltage-switching","display_name":"zero-voltage switching","score":0.8180000185966492},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"pulse width modulation","score":0.8259999752044678},{"id":"https://openalex.org/keywords/soft-commutation","display_name":"soft commutation","score":0.9549999833106995},{"id":"https://openalex.org/keywords/switch-voltage-stress-reduction","display_name":"switch voltage stress reduction","score":0.7730000019073486},{"id":"https://openalex.org/keywords/power-converter-topology","display_name":"converter topology","score":0.7739999890327454},{"id":"https://openalex.org/keywords/converter-efficiency","display_name":"converter efficiency","score":0.49300000071525574}],"concepts":[{"id":"https://openalex.org/C2780147050","wikidata":"https://www.wikidata.org/wiki/Q5155085","display_name":"Commutation","level":3,"score":0.6750292778015137},{"id":"https://openalex.org/C103357873","wikidata":"https://www.wikidata.org/wiki/Q572656","display_name":"Switched capacitor","level":4,"score":0.6664305925369263},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6259080171585083},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.6193835735321045},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.6153889894485474},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4805229604244232},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4310300350189209},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.36261314153671265},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.34041646122932434},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21426674723625183},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.36227/techrxiv.12991445.v1","doi":"https://doi.org/10.36227/techrxiv.12991445.v1","is_oa":true,"landing_page_url":"https://doi.org/10.36227/techrxiv.12991445.v1","pdf_url":"https://www.techrxiv.org/articles/preprint/Asymmetrical_ZVS-PWM_Switched-Capacitor_Based_Half-Bridge_DC-DC_Converter_With_Switch_Peak_Voltage_of_Vin_2/12991445/files/24752006.pdf","source":null,"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"}],"best_oa_location":{"id":"doi:10.36227/techrxiv.12991445.v1","doi":"https://doi.org/10.36227/techrxiv.12991445.v1","is_oa":true,"landing_page_url":"https://doi.org/10.36227/techrxiv.12991445.v1","pdf_url":"https://www.techrxiv.org/articles/preprint/Asymmetrical_ZVS-PWM_Switched-Capacitor_Based_Half-Bridge_DC-DC_Converter_With_Switch_Peak_Voltage_of_Vin_2/12991445/files/24752006.pdf","source":null,"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"posted-content"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.4943999946117401,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320324178","display_name":"Ag\u00eancia Nacional de Energia El\u00e9trica","ror":"https://ror.org/049sgh675"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4230056885.pdf","grobid_xml":"https://content.openalex.org/works/W4230056885.grobid-xml"},"referenced_works_count":20,"referenced_works":["https://openalex.org/W1947469465","https://openalex.org/W1963751889","https://openalex.org/W2035518468","https://openalex.org/W2111892078","https://openalex.org/W2123082907","https://openalex.org/W2124805565","https://openalex.org/W2157188874","https://openalex.org/W2171056358","https://openalex.org/W2496406240","https://openalex.org/W2533517361","https://openalex.org/W2541507240","https://openalex.org/W2545304583","https://openalex.org/W2898853779","https://openalex.org/W2923612013","https://openalex.org/W2972760148","https://openalex.org/W2973177803","https://openalex.org/W3035542846","https://openalex.org/W3035600279","https://openalex.org/W3161516307","https://openalex.org/W4246275857"],"related_works":["https://openalex.org/W3096630999","https://openalex.org/W4225271088","https://openalex.org/W2121710093","https://openalex.org/W2151952465","https://openalex.org/W2011515990","https://openalex.org/W2133306352","https://openalex.org/W2155725838","https://openalex.org/W2390081867","https://openalex.org/W4292608406","https://openalex.org/W4386861010"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,19,87],"new":[4],"power":[5,65],"converter":[6,17,46,55],"topology":[7],"generated":[8],"by":[9],"the":[10,13,32,38,44,50,57,60,64,68,71,77,111,115,122],"integration":[11],"of":[12,43,59,70,79,121],"asymmetrical":[14,52],"ZVS-PWM":[15],"dcdc":[16],"with":[18,29,47,90],"switched-capacitor":[20],"ladder-type":[21],"commutation":[22],"cell.":[23],"Circuit":[24],"operation":[25],"and":[26,102,114],"theoretical":[27,112],"analysis":[28,113],"emphasis":[30],"on":[31,86],"soft-commutation":[33],"process":[34],"are":[35,107],"included":[36],"in":[37],"paper.":[39],"The":[40,118],"main":[41],"advantage":[42],"proposed":[45],"respect":[48],"to":[49,67,109],"conventional":[51],"half-bridge":[53],"dc-dc":[54,132],"is":[56],"reduction":[58],"voltage":[61,81,101,137],"stress":[62],"across":[63],"switches":[66],"half":[69],"input":[72,96],"dc":[73],"bus":[74],"voltage,":[75,97],"enabling":[76],"utilization":[78],"lower":[80],"rating":[82],"components.":[83],"Experiments":[84],"conducted":[85],"laboratory":[88],"prototype":[89,125],"1.4":[91],"kW":[92],"power-rating,":[93],"800":[94],"V":[95,99],"48":[98],"output":[100],"100":[103],"kHz":[104],"switching":[105],"frequency":[106],"included,":[108],"verify":[110],"design":[116],"methodology.":[117],"maximum":[119],"efficiency":[120],"experimental":[123],"nonoptimized":[124],"was":[126],"93.6%.":[127],"Index":[128],"Terms":[129],"-":[130],"Asymmetrical":[131],"converter,":[133],"pulse-widthmodulation,":[134],"switched-capacitor,":[135],"zero":[136],"switching.":[138]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4230056885","counts_by_year":[],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2022-05-11T00:00:00"}
