{"id":"https://openalex.org/W4214814432","doi":"https://doi.org/10.1061/(asce)st.1943-541x.0003308","title":"Full-Scale Cross-Laminated Timber Diaphragm Evaluation. I: Design and Full-Scale Diaphragm Testing","display_name":"Full-Scale Cross-Laminated Timber Diaphragm Evaluation. I: Design and Full-Scale Diaphragm Testing","publication_year":2022,"publication_date":"2022-03-04","ids":{"openalex":"https://openalex.org/W4214814432","doi":"https://doi.org/10.1061/(asce)st.1943-541x.0003308"},"language":"en","primary_location":{"id":"doi:10.1061/(asce)st.1943-541x.0003308","doi":"https://doi.org/10.1061/(asce)st.1943-541x.0003308","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)st.1943-541x.0003308","pdf_url":null,"source":{"id":"https://openalex.org/S93312259","display_name":"Journal of Structural Engineering","issn_l":"0733-9445","issn":["0733-9445","1943-541X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Structural Engineering","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078394173","display_name":"Philip Line","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Philip Line","raw_affiliation_strings":["Director, Structural Engineering, American Wood Council, 222 Catoctin Circle SE Suite 201, Leesburg, VA 20175 (corresponding author)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Director, Structural Engineering, American Wood Council, 222 Catoctin Circle SE Suite 201, Leesburg, VA 20175 (corresponding author)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016313302","display_name":"Scott Nyseth","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Scott Nyseth","raw_affiliation_strings":["President, Stonewood Structural Engineers, 2001 NW 19th Ave., STE 103A, Portland, OR 97209"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"President, Stonewood Structural Engineers, 2001 NW 19th Ave., STE 103A, Portland, OR 97209","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049577408","display_name":"Ned Waltz","orcid":"https://orcid.org/0009-0005-1588-0578","observed_orcids":["https://orcid.org/0009-0005-1588-0578"]},"institutions":[{"id":"https://openalex.org/I194059303","display_name":"Weyerhaeuser (United States)","ror":"https://ror.org/015pwzh41","country_code":"US","type":"company","lineage":["https://openalex.org/I194059303"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ned Waltz","raw_affiliation_strings":["Senior Engineer, Product Evaluation and Performance, Weyerhaeuser, P.O. Box 6049, Federal Way, WA 98063"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Senior Engineer, Product Evaluation and Performance, Weyerhaeuser, P.O. Box 6049, Federal Way, WA 98063","institution_ids":["https://openalex.org/I194059303"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5078394173"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.3803,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.77224347,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"148","issue":"5","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.7202000021934509,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.7202000021934509,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10484","display_name":"Wood Treatment and Properties","score":0.13269999623298645,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10713","display_name":"Structural Load-Bearing Analysis","score":0.028200000524520874,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cross-laminated-timber","display_name":"cross-laminated timber","score":0.9919999837875366},{"id":"https://openalex.org/keywords/design-conservatism","display_name":"design conservatism","score":0.6240000128746033}],"concepts":[{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.8336069583892822},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5695145726203918},{"id":"https://openalex.org/C2776748203","wikidata":"https://www.wikidata.org/wiki/Q83180","display_name":"Roof","level":2,"score":0.5222119688987732},{"id":"https://openalex.org/C164292776","wikidata":"https://www.wikidata.org/wiki/Q5271779","display_name":"Diaphragm (acoustics)","level":3,"score":0.5162477493286133},{"id":"https://openalex.org/C182358397","wikidata":"https://www.wikidata.org/wiki/Q2656128","display_name":"Seismic analysis","level":2,"score":0.45044153928756714},{"id":"https://openalex.org/C2778529468","wikidata":"https://www.wikidata.org/wiki/Q911043","display_name":"Cross laminated timber","level":2,"score":0.42971915006637573},{"id":"https://openalex.org/C96035792","wikidata":"https://www.wikidata.org/wiki/Q43606218","display_name":"Shear (geology)","level":2,"score":0.42073532938957214},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.39384597539901733},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.15087279677391052},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.13765659928321838},{"id":"https://openalex.org/C157138929","wikidata":"https://www.wikidata.org/wiki/Q570","display_name":"Loudspeaker","level":2,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1061/(asce)st.1943-541x.0003308","doi":"https://doi.org/10.1061/(asce)st.1943-541x.0003308","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)st.1943-541x.0003308","pdf_url":null,"source":{"id":"https://openalex.org/S93312259","display_name":"Journal of Structural Engineering","issn_l":"0733-9445","issn":["0733-9445","1943-541X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Structural Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.4943999946117401,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W3118431439","https://openalex.org/W3124628317","https://openalex.org/W4214943876"],"related_works":["https://openalex.org/W4214943876","https://openalex.org/W3118431439","https://openalex.org/W7166255783","https://openalex.org/W2799993569","https://openalex.org/W4389004448","https://openalex.org/W2991413136","https://openalex.org/W3030639061","https://openalex.org/W7037802878","https://openalex.org/W4229063590","https://openalex.org/W3153371778"],"abstract_inverted_index":{"The":[0,110,133,162],"objective":[1],"of":[2,20,77,144,177,228],"this":[3,192],"study":[4,249],"was":[5,126,183],"to":[6,140,150,219,233],"monotonically":[7],"test":[8,71,180],"two":[9],"7.32\u00d77.32-m":[10],"(24\u00d724-ft)":[11],"cross-laminated":[12],"timber":[13],"(CLT)":[14],"diaphragms":[15],"designed":[16],"using":[17],"the":[18,122,141,145,157,166,173,178,186,198,203,208,234,238,245],"provisions":[19,27,201],"ANSI/AWC":[21,32],"2021":[22],"(AWC.":[23],"2021.":[24],"Special":[25],"design":[26,115,160,189,200,209,221],"for":[28,73,84,98,107,117,215],"wind":[29],"and":[30,45,80],"seismic.":[31],"SDPWS-2021,":[33],"Leesburg,":[34],"VA:":[35],"AWC).":[36],"Each":[37],"diaphragm":[38,82,134,163,229,240],"used":[39,92,102,236],"twelve":[40],"1.22\u00d73.66-m":[41],"(4\u00d712-ft)":[42],"CLT":[43,146],"panels":[44,147],"plywood":[46],"splines":[47],"or":[48],"glulam":[49],"beams":[50],"at":[51,154,172],"panel":[52,123],"shear":[53,114,124],"connection":[54,230],"locations.":[55],"Diaphragms":[56],"were":[57],"tested":[58,135,164],"in":[59,62,165,237,244],"simple-span":[60],"bending":[61],"general":[63],"accordance":[64],"with":[65,136],"ASTM":[66,86],"E455":[67],"(ASTM.":[68],"2017.":[69],"Standard":[70],"method":[72],"static":[74],"load":[75,137],"testing":[76,193,241],"framed":[78],"floor":[79],"roof":[81],"constructions":[83],"buildings.":[85],"E455-2017.":[87],"West":[88],"Conshohocken,":[89],"PA:":[90],"ASTM),":[91],"8d":[93],"common":[94],"[3.3\u00d763.5-mm":[95],"(0.131\u00d72.5-in.)]":[96],"nails":[97],"panel-to-panel":[99],"spline":[100,151],"connections":[101,235],"proprietary":[103],"7.9\u00d7200-mm":[104],"(5/16\u00d77-7/8-in.)":[105],"screws":[106],"panel-to-beam":[108],"connections.":[109],"calculated":[111],"allowable":[112,158,187],"seismic":[113,159,188],"capacity":[116,176],"both":[118],"configurations,":[119],"based":[120],"on":[121],"connections,":[125],"60.5":[127],"kN":[128],"(13.6":[129],"kips)":[130],"per":[131],"reaction.":[132],"applied":[138],"parallel":[139],"long":[142],"dimension":[143],"failed":[148],"due":[149],"nail":[152],"withdrawal":[153],"4.0":[155],"times":[156,185],"capacity.":[161,190],"orthogonal":[167],"orientation":[168],"did":[169],"not":[170],"fail":[171],"safe":[174],"working":[175],"steel":[179],"frame,":[181],"which":[182],"6.0":[184],"Although":[191],"provided":[194],"empirical":[195],"verification":[196],"that":[197],"SDPWS":[199],"met":[202],"minimum":[204],"strength":[205],"target":[206],"underlying":[207],"requirements,":[210],"it":[211],"also":[212],"identified":[213],"opportunities":[214],"potential":[216],"future":[217],"research":[218],"reduce":[220],"conservatism.":[222],"Experimental":[223],"results":[224],"from":[225],"a":[226],"series":[227],"tests":[231],"correlated":[232],"full-scale":[239],"are":[242],"described":[243],"Part":[246],"2":[247],"companion":[248],"(Line":[250],"et":[251],"al.,":[252],"forthcoming).":[253]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":3}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2022-03-05T00:00:00"}
