{"id":"https://openalex.org/W4200465792","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0001179","title":"Seismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete","display_name":"Seismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete","publication_year":2021,"publication_date":"2021-12-14","ids":{"openalex":"https://openalex.org/W4200465792","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0001179"},"language":"en","primary_location":{"id":"doi:10.1061/(asce)cc.1943-5614.0001179","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0001179","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)cc.1943-5614.0001179","pdf_url":null,"source":{"id":"https://openalex.org/S33209994","display_name":"Journal of Composites for Construction","issn_l":"1090-0268","issn":["1090-0268","1943-5614"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Composites for Construction","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022664551","display_name":"\u0130dris Bedirhano\u011flu","orcid":"https://orcid.org/0000-0001-6852-3041","observed_orcids":["https://orcid.org/0000-0001-6852-3041"]},"institutions":[{"id":"https://openalex.org/I120250893","display_name":"New York University Abu Dhabi","ror":"https://ror.org/00e5k0821","country_code":"AE","type":"education","lineage":["https://openalex.org/I120250893","https://openalex.org/I57206974"]},{"id":"https://openalex.org/I123466251","display_name":"Dicle University","ror":"https://ror.org/0257dtg16","country_code":"TR","type":"education","lineage":["https://openalex.org/I123466251"]}],"countries":["AE","TR"],"is_corresponding":true,"raw_author_name":"Idris Bedirhanoglu","raw_affiliation_strings":["Research Scientist, Civil Engineering Dept., Engineering Faculty, New York Univ. Abu Dhabi, Abu Dhabi, UAE; Associate Professor, Civil Engineering Dept., Engineering Faculty, Dicle Univ., Diyarbak\u0131r, Turkey (corresponding author). ORCID: "],"raw_orcid":"https://orcid.org/0000-0001-6852-3041","affiliations":[{"raw_affiliation_string":"Research Scientist, Civil Engineering Dept., Engineering Faculty, New York Univ. Abu Dhabi, Abu Dhabi, UAE; Associate Professor, Civil Engineering Dept., Engineering Faculty, Dicle Univ., Diyarbak\u0131r, Turkey (corresponding author). ORCID: ","institution_ids":["https://openalex.org/I120250893","https://openalex.org/I123466251"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051965326","display_name":"Alper \u0130lki","orcid":"https://orcid.org/0000-0002-4853-7910","observed_orcids":["https://orcid.org/0000-0002-4853-7910"]},"institutions":[{"id":"https://openalex.org/I48912391","display_name":"Istanbul Technical University","ror":"https://ror.org/059636586","country_code":"TR","type":"education","lineage":["https://openalex.org/I48912391"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Alper Ilki","raw_affiliation_strings":["Professor, Civil Engineering Faculty, Istanbul Technical Univ., Istanbul, Turkey"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Professor, Civil Engineering Faculty, Istanbul Technical Univ., Istanbul, Turkey","institution_ids":["https://openalex.org/I48912391"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5041831839","display_name":"Thanasis Triantafillou","orcid":"https://orcid.org/0000-0003-0263-3955","observed_orcids":["https://orcid.org/0000-0003-0263-3955"]},"institutions":[{"id":"https://openalex.org/I120250893","display_name":"New York University Abu Dhabi","ror":"https://ror.org/00e5k0821","country_code":"AE","type":"education","lineage":["https://openalex.org/I120250893","https://openalex.org/I57206974"]},{"id":"https://openalex.org/I174878644","display_name":"University of Patras","ror":"https://ror.org/017wvtq80","country_code":"GR","type":"education","lineage":["https://openalex.org/I174878644"]}],"countries":["AE","GR"],"is_corresponding":false,"raw_author_name":"Thanasis C. Triantafillou","raw_affiliation_strings":["Dept. of Civil Engineering, Univ. of Patras, Patras, Greece; Visiting Global Distinguished Professor of Civil and Urban Engineering, New York Univ. Abu Dhabi, Abu Dhabi, UAE. ORCID: ","Dept. of Civil Engineering, Univ. of Patras, Patras, Greece"],"raw_orcid":"https://orcid.org/0000-0003-0263-3955","affiliations":[{"raw_affiliation_string":"Dept. of Civil Engineering, Univ. of Patras, Patras, Greece; Visiting Global Distinguished Professor of Civil and Urban Engineering, New York Univ. Abu Dhabi, Abu Dhabi, UAE. ORCID: ","institution_ids":["https://openalex.org/I120250893","https://openalex.org/I174878644"]},{"raw_affiliation_string":"Dept. of Civil Engineering, Univ. of Patras, Patras, Greece","institution_ids":["https://openalex.org/I174878644"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5022664551"],"corresponding_institution_ids":["https://openalex.org/I120250893","https://openalex.org/I123466251"],"apc_list":null,"apc_paid":null,"fwci":2.7442,"has_fulltext":false,"cited_by_count":37,"citation_normalized_percentile":{"value":0.89258418,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"26","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.005200000014156103,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11352","display_name":"Masonry and Concrete Structural Analysis","score":0.0031999999191612005,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/short-columns","display_name":"short columns","score":0.8230000138282776},{"id":"https://openalex.org/keywords/frp-jacketing","display_name":"FRP jacketing","score":0.7879999876022339},{"id":"https://openalex.org/keywords/low-strength-concrete","display_name":"low-strength concrete","score":0.9309999942779541},{"id":"https://openalex.org/keywords/seismic-behavior","display_name":"seismic behavior","score":0.7250000238418579},{"id":"https://openalex.org/keywords/shear-strength","display_name":"shear strength","score":0.5509999990463257},{"id":"https://openalex.org/keywords/column-repair","display_name":"column repair","score":0.6299999952316284},{"id":"https://openalex.org/keywords/transverse-reinforcement-spacing","display_name":"transverse reinforcement spacing","score":0.6980000138282776},{"id":"https://openalex.org/keywords/reinforced-concrete-columns","display_name":"reinforced concrete columns","score":0.6470000147819519},{"id":"https://openalex.org/keywords/design-code-prediction","display_name":"design code prediction","score":0.4000000059604645},{"id":"https://openalex.org/keywords/seismic-retrofitting","display_name":"seismic retrofitting","score":0.5120000243186951}],"concepts":[{"id":"https://openalex.org/C76344452","wikidata":"https://www.wikidata.org/wiki/Q263125","display_name":"Fibre-reinforced plastic","level":2,"score":0.904238224029541},{"id":"https://openalex.org/C2778368411","wikidata":"https://www.wikidata.org/wiki/Q24662","display_name":"Retrofitting","level":2,"score":0.8586901426315308},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.7549991607666016},{"id":"https://openalex.org/C29979489","wikidata":"https://www.wikidata.org/wiki/Q2468944","display_name":"Seismic retrofit","level":3,"score":0.6740448474884033},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6150623559951782},{"id":"https://openalex.org/C2988805333","wikidata":"https://www.wikidata.org/wiki/Q184190","display_name":"Reinforced concrete","level":2,"score":0.531450629234314},{"id":"https://openalex.org/C2780551164","wikidata":"https://www.wikidata.org/wiki/Q2306599","display_name":"Column (typography)","level":3,"score":0.4921790659427643},{"id":"https://openalex.org/C127893833","wikidata":"https://www.wikidata.org/wiki/Q7492185","display_name":"Shear strength (soil)","level":3,"score":0.4725213646888733},{"id":"https://openalex.org/C67203356","wikidata":"https://www.wikidata.org/wiki/Q1321905","display_name":"Reinforcement","level":2,"score":0.44086018204689026},{"id":"https://openalex.org/C96035792","wikidata":"https://www.wikidata.org/wiki/Q43606218","display_name":"Shear (geology)","level":2,"score":0.4318453073501587},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.3384855389595032},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.3166440725326538},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2602311968803406},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.17626497149467468},{"id":"https://openalex.org/C13355873","wikidata":"https://www.wikidata.org/wiki/Q2920850","display_name":"Connection (principal bundle)","level":2,"score":0.0},{"id":"https://openalex.org/C159750122","wikidata":"https://www.wikidata.org/wiki/Q96621023","display_name":"Soil water","level":2,"score":0.0},{"id":"https://openalex.org/C159390177","wikidata":"https://www.wikidata.org/wiki/Q9161265","display_name":"Soil science","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1061/(asce)cc.1943-5614.0001179","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0001179","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)cc.1943-5614.0001179","pdf_url":null,"source":{"id":"https://openalex.org/S33209994","display_name":"Journal of Composites for Construction","issn_l":"1090-0268","issn":["1090-0268","1943-5614"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Composites for Construction","raw_type":"journal-article"},{"id":"pmh:oai:polen.itu.edu.tr:11527/63130","doi":null,"is_oa":false,"landing_page_url":"https://hdl.handle.net/11527/63130","pdf_url":null,"source":{"id":"https://openalex.org/S4306400460","display_name":"Istanbul Technical University Academic Open Archive (Istanbul Technical University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I48912391","host_organization_name":"Istanbul Technical University","host_organization_lineage":["https://openalex.org/I48912391"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W644710593","https://openalex.org/W1491222482","https://openalex.org/W1566242257","https://openalex.org/W1991367745","https://openalex.org/W2004284095","https://openalex.org/W2042809168","https://openalex.org/W2047364878","https://openalex.org/W2048989760","https://openalex.org/W2055616363","https://openalex.org/W2068208639","https://openalex.org/W2077424511","https://openalex.org/W2093556952","https://openalex.org/W2094987727","https://openalex.org/W2099241724","https://openalex.org/W2100568570","https://openalex.org/W2109299972","https://openalex.org/W2133303254","https://openalex.org/W2162975707","https://openalex.org/W2171845467","https://openalex.org/W2171966268","https://openalex.org/W2185779093","https://openalex.org/W2207180997","https://openalex.org/W2260406045","https://openalex.org/W2312424739","https://openalex.org/W2580637098","https://openalex.org/W2898176135","https://openalex.org/W2975924419","https://openalex.org/W2982651791","https://openalex.org/W3015933597","https://openalex.org/W3020596767","https://openalex.org/W3022843484","https://openalex.org/W3023371398"],"related_works":["https://openalex.org/W2379212923","https://openalex.org/W2484326443","https://openalex.org/W3180883409","https://openalex.org/W2133303254","https://openalex.org/W2790758010","https://openalex.org/W2900936577","https://openalex.org/W2590868275","https://openalex.org/W2392042658","https://openalex.org/W2801211421","https://openalex.org/W3015933597"],"abstract_inverted_index":{"Short":[0],"columns":[1,79,100,132,165,211],"with":[2,101,213],"deficiencies":[3],"of":[4,10,35,44,54,71,75,86,95,108,122,130,176,181,184,189,200,209,221],"low-strength":[5,97,178],"concrete":[6,62],"and":[7,102,115,133,137,142,160,162,180,223],"large":[8],"spacing":[9],"transverse":[11],"reinforcement":[12],"are":[13,145,166],"quite":[14],"common":[15],"in":[16,19,23,41,204],"construction":[17],"practice":[18],"many":[20],"developing":[21],"countries":[22],"seismically":[24],"active":[25],"regions.":[26],"Therefore,":[27],"it":[28],"is":[29,52,80],"important":[30,171],"to":[31,37,59,90],"retrofit":[32,60],"this":[33,87],"type":[34],"column":[36,111],"avoid":[38],"negative":[39],"consequences":[40],"the":[42,55,72,84,92,106,120,127,148,174,187,195,198,206,219],"case":[43],"severe":[45],"damage.":[46],"External":[47],"fiber\u2013reinforced":[48],"polymer":[49],"(FRP)":[50],"jacketing":[51,215],"one":[53],"most":[56],"practical":[57],"methods":[58],"reinforced":[61],"(RC)":[63],"frame":[64],"members":[65],"against":[66],"shear":[67,207],"actions.":[68],"However,":[69],"knowledge":[70,172],"seismic":[73,93,128],"behavior":[74,129,188],"FRP-retrofitted":[76,96,157,190],"RC":[77,98,117],"short":[78,99,110,155,158,164,192],"still":[81],"limited.":[82],"Thus,":[83],"aim":[85],"study":[88],"was":[89,216],"investigate":[91],"response":[94],"without":[103],"predamage":[104,185],"through":[105,218],"testing":[107],"11":[109],"specimens":[112],"representing":[113],"old":[114],"deficient":[116],"buildings.":[118],"Accordingly,":[119],"results":[121,152,169],"a":[123],"research":[124],"program":[125],"on":[126,134,186],"such":[131,210],"their":[135],"repair":[136],"FRP":[138,214],"retrofitting,":[139],"covering":[140],"experimental":[141,149,224],"analytical":[143,196],"phases,":[144],"presented.":[146],"In":[147,194],"phase,":[150,197],"test":[151],"obtained":[153],"for":[154],"columns,":[156,159],"repaired":[161],"retrofitted":[163,212],"documented.":[167],"Test":[168],"provide":[170],"about":[173],"effects":[175],"extremely":[177],"concrete,":[179],"different":[182],"levels":[183],"substandard":[191],"columns.":[193],"performance":[199],"relevant":[201],"design":[202],"documents":[203],"predicting":[205],"strength":[208],"tested":[217],"comparison":[220],"predicted":[222],"results.":[225]},"counts_by_year":[{"year":2026,"cited_by_count":7},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":8},{"year":2023,"cited_by_count":9},{"year":2022,"cited_by_count":7}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2021-12-31T00:00:00"}
