{"id":"https://openalex.org/W4200326601","doi":"https://doi.org/10.1186/s41601-021-00218-7","title":"A robust model-free controller for a three-phase grid-connected photovoltaic system based on ultra-local model","display_name":"A robust model-free controller for a three-phase grid-connected photovoltaic system based on ultra-local model","publication_year":2021,"publication_date":"2021-12-01","ids":{"openalex":"https://openalex.org/W4200326601","doi":"https://doi.org/10.1186/s41601-021-00218-7"},"language":"en","primary_location":{"id":"doi:10.1186/s41601-021-00218-7","doi":"https://doi.org/10.1186/s41601-021-00218-7","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s41601-021-00218-7","pdf_url":"https://pcmp.springeropen.com/track/pdf/10.1186/s41601-021-00218-7","source":{"id":"https://openalex.org/S2737292043","display_name":"Protection and Control of Modern Power Systems","issn_l":"2367-0983","issn":["2367-0983","2367-2617"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","oarl","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319900","host_organization_name":"Springer Science+Business Media","host_organization_lineage":["https://openalex.org/P4310319900","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Science+Business Media","Springer Nature"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Protection and Control of Modern Power Systems","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://pcmp.springeropen.com/track/pdf/10.1186/s41601-021-00218-7","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028346462","display_name":"Ahsene Boubakir","orcid":"https://orcid.org/0000-0003-1772-4446","observed_orcids":["https://orcid.org/0000-0003-1772-4446"]},"institutions":[{"id":"https://openalex.org/I116970179","display_name":"University of Jijel","ror":"https://ror.org/03kkfk814","country_code":"DZ","type":"education","lineage":["https://openalex.org/I116970179"]}],"countries":["DZ"],"is_corresponding":true,"raw_author_name":"Ahsene Boubakir","raw_affiliation_strings":["LAJ, Faculty of Science and Technology, University of Jijel, BP. 98, Ouled Aissa, 18000, Jijel, Algeria"],"raw_orcid":"https://orcid.org/0000-0003-1772-4446","affiliations":[{"raw_affiliation_string":"LAJ, Faculty of Science and Technology, University of Jijel, BP. 98, Ouled Aissa, 18000, Jijel, Algeria","institution_ids":["https://openalex.org/I116970179"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021162885","display_name":"Sid\u2010Ahmed Touil","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I116970179","display_name":"University of Jijel","ror":"https://ror.org/03kkfk814","country_code":"DZ","type":"education","lineage":["https://openalex.org/I116970179"]}],"countries":["DZ"],"is_corresponding":false,"raw_author_name":"Sid-Ahmed Touil","raw_affiliation_strings":["Department of Electrical Engineering, University of Jijel, Jijel, Algeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Jijel, Jijel, Algeria","institution_ids":["https://openalex.org/I116970179"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083800207","display_name":"Salim Labiod","orcid":"https://orcid.org/0000-0002-6304-6730","observed_orcids":["https://orcid.org/0000-0002-6304-6730"]},"institutions":[{"id":"https://openalex.org/I116970179","display_name":"University of Jijel","ror":"https://ror.org/03kkfk814","country_code":"DZ","type":"education","lineage":["https://openalex.org/I116970179"]}],"countries":["DZ"],"is_corresponding":false,"raw_author_name":"Salim Labiod","raw_affiliation_strings":["LAJ, Faculty of Science and Technology, University of Jijel, BP. 98, Ouled Aissa, 18000, Jijel, Algeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LAJ, Faculty of Science and Technology, University of Jijel, BP. 98, Ouled Aissa, 18000, Jijel, Algeria","institution_ids":["https://openalex.org/I116970179"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037244539","display_name":"Nasserdine Boudjerda","orcid":"https://orcid.org/0000-0002-3988-6086","observed_orcids":["https://orcid.org/0000-0002-3988-6086"]},"institutions":[{"id":"https://openalex.org/I116970179","display_name":"University of Jijel","ror":"https://ror.org/03kkfk814","country_code":"DZ","type":"education","lineage":["https://openalex.org/I116970179"]}],"countries":["DZ"],"is_corresponding":false,"raw_author_name":"Nasserdine Boudjerda","raw_affiliation_strings":["LER, Faculty of Sciences and Technology, University of Jijel, BP 98, Ouled Aissa, 18000, Jijel, Algeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LER, Faculty of Sciences and Technology, University of Jijel, BP 98, Ouled Aissa, 18000, Jijel, Algeria","institution_ids":["https://openalex.org/I116970179"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5028346462"],"corresponding_institution_ids":["https://openalex.org/I116970179"],"apc_list":{"value":0,"currency":"USD","value_usd":0},"apc_paid":{"value":0,"currency":"USD","value_usd":0},"fwci":0.3958,"has_fulltext":true,"cited_by_count":21,"citation_normalized_percentile":{"value":0.49031514,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":99},"biblio":{"volume":"6","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.8574000000953674,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.8574000000953674,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.08269999921321869,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.009800000116229057,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/model-free-control","display_name":"model-free control","score":0.9539999961853027},{"id":"https://openalex.org/keywords/ultra-local-model","display_name":"ultra-local model","score":0.9390000104904175},{"id":"https://openalex.org/keywords/grid-connected-photovoltaic-systems","display_name":"grid-connected photovoltaic systems","score":0.9020000100135803},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"maximum power point tracking","score":0.8610000014305115},{"id":"https://openalex.org/keywords/reactive-power-control","display_name":"reactive power control","score":0.9729999899864197},{"id":"https://openalex.org/keywords/current-quality","display_name":"current quality","score":0.578000009059906},{"id":"https://openalex.org/keywords/dc-ac-inverter","display_name":"DC-AC inverter","score":0.9319999814033508},{"id":"https://openalex.org/keywords/numerical-differentiation","display_name":"numerical differentiation","score":0.5189999938011169},{"id":"https://openalex.org/keywords/robust-control","display_name":"robust control","score":0.7289999723434448},{"id":"https://openalex.org/keywords/parameter-variation-compensation","display_name":"parameter variation compensation","score":0.4390000104904175},{"id":"https://openalex.org/keywords/disturbance-compensation","display_name":"disturbance compensation","score":0.6340000033378601}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7804148197174072},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7450262904167175},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6427379846572876},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6323826313018799},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5315563082695007},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.48467209935188293},{"id":"https://openalex.org/C12112733","wikidata":"https://www.wikidata.org/wiki/Q2659948","display_name":"Differentiator","level":3,"score":0.45100510120391846},{"id":"https://openalex.org/C28427503","wikidata":"https://www.wikidata.org/wiki/Q13580300","display_name":"Internal model","level":3,"score":0.4445631206035614},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.4107932150363922},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.34654131531715393},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.3178119659423828},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2574814558029175},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.19180843234062195},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.11460164189338684},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.10895049571990967},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.08736124634742737},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.07852071523666382},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.06886619329452515},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1186/s41601-021-00218-7","doi":"https://doi.org/10.1186/s41601-021-00218-7","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s41601-021-00218-7","pdf_url":"https://pcmp.springeropen.com/track/pdf/10.1186/s41601-021-00218-7","source":{"id":"https://openalex.org/S2737292043","display_name":"Protection and Control of Modern Power Systems","issn_l":"2367-0983","issn":["2367-0983","2367-2617"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","oarl","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319900","host_organization_name":"Springer Science+Business Media","host_organization_lineage":["https://openalex.org/P4310319900","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Science+Business Media","Springer Nature"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Protection and Control of Modern Power Systems","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:0a6b62e733104c4c91d190d6dc1d7754","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/0a6b62e733104c4c91d190d6dc1d7754","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Protection and Control of Modern Power Systems, Vol 6, Iss 1, Pp 1-13 (2021)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1186/s41601-021-00218-7","doi":"https://doi.org/10.1186/s41601-021-00218-7","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s41601-021-00218-7","pdf_url":"https://pcmp.springeropen.com/track/pdf/10.1186/s41601-021-00218-7","source":{"id":"https://openalex.org/S2737292043","display_name":"Protection and Control of Modern Power Systems","issn_l":"2367-0983","issn":["2367-0983","2367-2617"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","oarl","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319900","host_organization_name":"Springer Science+Business Media","host_organization_lineage":["https://openalex.org/P4310319900","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Science+Business Media","Springer Nature"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Protection and Control of Modern Power Systems","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9853000044822693},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.6773999929428101}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320335007","display_name":"Direction G\u00e9n\u00e9rale de la Recherche Scientifique et du D\u00e9veloppement Technologique","ror":"https://ror.org/04jpfrv51"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4200326601.pdf","grobid_xml":"https://content.openalex.org/works/W4200326601.grobid-xml"},"referenced_works_count":36,"referenced_works":["https://openalex.org/W1078539226","https://openalex.org/W1992642370","https://openalex.org/W2019375098","https://openalex.org/W2035192473","https://openalex.org/W2067887469","https://openalex.org/W2077651383","https://openalex.org/W2087747235","https://openalex.org/W2109509029","https://openalex.org/W2138241565","https://openalex.org/W2155546972","https://openalex.org/W2320421188","https://openalex.org/W2333158525","https://openalex.org/W2467054278","https://openalex.org/W2512061413","https://openalex.org/W2593975450","https://openalex.org/W2607443033","https://openalex.org/W2609544495","https://openalex.org/W2787387053","https://openalex.org/W2795397175","https://openalex.org/W2803319209","https://openalex.org/W2809336559","https://openalex.org/W2907566263","https://openalex.org/W2911074114","https://openalex.org/W2911234965","https://openalex.org/W2920970153","https://openalex.org/W2942011937","https://openalex.org/W2951516141","https://openalex.org/W2964275488","https://openalex.org/W2965853750","https://openalex.org/W2974606090","https://openalex.org/W3008825723","https://openalex.org/W3033560429","https://openalex.org/W3034923965","https://openalex.org/W4253469688","https://openalex.org/W4292872153","https://openalex.org/W6748323271"],"related_works":["https://openalex.org/W2143728235","https://openalex.org/W2333158525","https://openalex.org/W2907566263","https://openalex.org/W2998934876","https://openalex.org/W2041171622","https://openalex.org/W2738347825","https://openalex.org/W2946265215","https://openalex.org/W2797754542","https://openalex.org/W2045409997","https://openalex.org/W2359957326"],"abstract_inverted_index":{"Abstract":[0],"In":[1],"this":[2],"paper,":[3],"a":[4,9,20,25,29,95,112,117],"robust":[5],"model-free":[6,66,108],"controller":[7,109,115,136],"for":[8,119,137],"grid-connected":[10,138],"photovoltaic":[11],"(PV)":[12],"system":[13,17,38],"is":[14,69,90],"designed.":[15],"The":[16,32,65,87,107],"consists":[18,110],"of":[19,35,58,74,79,83,103,111,122,134],"PV":[21,46,139],"generator":[22],"connected":[23],"to":[24,40,48,54],"three-phase":[26],"grid":[27],"by":[28],"DC/AC":[30],"converter.":[31],"control":[33,49,67],"objectives":[34],"the":[36,45,56,59,63,72,80,84,100,104,120,132,135],"overall":[37,85],"are":[39],"extract":[41],"maximum":[42],"power":[43,51],"from":[44],"source,":[47],"reactive":[50],"exchange":[52],"and":[53,116,126],"improve":[55],"quality":[57],"current":[60],"injected":[61],"into":[62],"grid.":[64],"technique":[68],"based":[70,93],"on":[71,94],"use":[73],"an":[75],"ultra-local":[76],"model":[77,82,89],"instead":[78],"dynamic":[81],"system.":[86,106],"local":[88],"continuously":[91],"updated":[92],"numerical":[96],"differentiator":[97],"using":[98],"only":[99],"input\u2013output":[101],"behavior":[102],"controlled":[105],"classical":[113],"feedback":[114],"compensator":[118],"effects":[121],"internal":[123],"parameter":[124],"changes":[125],"external":[127],"disturbances.":[128],"Simulation":[129],"results":[130],"illustrate":[131],"efficiency":[133],"systems.":[140]},"counts_by_year":[{"year":2026,"cited_by_count":6},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":4}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2021-12-31T00:00:00"}