{"id":"https://openalex.org/W41280217","doi":null,"title":"Fault location techniques for high-voltage dc lines. Final report","display_name":"Fault location techniques for high-voltage dc lines. Final report","publication_year":1985,"publication_date":"1985-12-01","ids":{"openalex":"https://openalex.org/W41280217","mag":"41280217"},"language":"en","primary_location":{"id":"mag:41280217","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/6478765-fault-location-techniques-high-voltage-dc-lines-final-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111723938","display_name":"E.O. Schweitzer","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"E.O. Schweitzer","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Mai Ando","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mai Ando","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5083171726","display_name":"R. Baker","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R. Baker","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.005232,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.5673999786376953,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.5673999786376953,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.4009000062942505,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.019700000062584877,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-localization","display_name":"fault location","score":0.9409999847412109},{"id":"https://openalex.org/keywords/hvdc-transmission-lines","display_name":"HVDC transmission lines","score":0.8769999742507935},{"id":"https://openalex.org/keywords/reflectometry","display_name":"reflectometry","score":0.7149999737739563}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6956238746643066},{"id":"https://openalex.org/C186379835","wikidata":"https://www.wikidata.org/wiki/Q253276","display_name":"Mile","level":2,"score":0.6516127586364746},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.6420849561691284},{"id":"https://openalex.org/C2780604831","wikidata":"https://www.wikidata.org/wiki/Q174320","display_name":"Oscillograph","level":2,"score":0.6049214601516724},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5237241387367249},{"id":"https://openalex.org/C2778925768","wikidata":"https://www.wikidata.org/wiki/Q3454718","display_name":"Reflectometry","level":3,"score":0.5225303173065186},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.48808419704437256},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.46082815527915955},{"id":"https://openalex.org/C137800194","wikidata":"https://www.wikidata.org/wiki/Q11713455","display_name":"Interpolation (computer graphics)","level":3,"score":0.4394316077232361},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4346562623977661},{"id":"https://openalex.org/C135981907","wikidata":"https://www.wikidata.org/wiki/Q188056","display_name":"Triangulation","level":2,"score":0.4217385947704315},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3840615153312683},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.32717686891555786},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.1723695695400238},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.17187505960464478},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.1492474377155304},{"id":"https://openalex.org/C103824480","wikidata":"https://www.wikidata.org/wiki/Q185889","display_name":"Time domain","level":2,"score":0.13068607449531555},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1281524896621704},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.1162501871585846},{"id":"https://openalex.org/C126042441","wikidata":"https://www.wikidata.org/wiki/Q1324888","display_name":"Frame (networking)","level":2,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:41280217","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/6478765-fault-location-techniques-high-voltage-dc-lines-final-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2044586239","https://openalex.org/W2460352301","https://openalex.org/W3114795631","https://openalex.org/W3141073250","https://openalex.org/W3007151001","https://openalex.org/W2898332063","https://openalex.org/W2898891254","https://openalex.org/W3120780860","https://openalex.org/W2784081256","https://openalex.org/W2791211566","https://openalex.org/W1489294796","https://openalex.org/W1855285727","https://openalex.org/W2914337784","https://openalex.org/W2998294248","https://openalex.org/W3027704054","https://openalex.org/W2607211924","https://openalex.org/W2901662847","https://openalex.org/W3094203440","https://openalex.org/W2990302739","https://openalex.org/W2917987748"],"abstract_inverted_index":{"This":[0],"report":[1],"describes":[2],"a":[3,8,43,65,117,160,165],"fault":[4,69,99,119],"location":[5,70],"technique":[6,14],"for":[7],"two-terminal":[9],"HVDC":[10,133,175],"line.":[11,178],"The":[12,34,68,111],"new":[13],"uses":[15,36],"information":[16],"from":[17,73,86,97],"only":[18],"one":[19],"end":[20,89,103],"of":[21,47,56,76,81,90,104,130,151,171],"the":[22,45,48,53,57,79,84,87,91,95,98,101,105,126,131,139,152,154,157,169,172],"line":[23,92,106],"and":[24,121,159],"it":[25,122],"is":[26,71,163],"referred":[27],"to":[28,100,116],"as":[29],"simple":[30],"passive":[31],"reflectometer":[32],"(SPR).":[33],"SPR":[35,112,158],"successive":[37],"reflections":[38,49,61,85],"generated":[39],"by":[40],"faults.":[41,148],"Using":[42],"differentiator-smoother,":[44],"arrivals":[46],"are":[50,62,93],"detected.":[51],"Furthermore,":[52],"arrival":[54],"times":[55,75],"first":[58],"two":[59],"consecutive":[60],"estimated":[63],"using":[64,78],"triangulation-interpolation":[66],"scheme.":[67],"computed":[72],"these":[74],"arrival,":[77],"principles":[80],"reflectometry.":[82],"If":[83],"other":[88,102],"detected,":[94],"distance":[96],"can":[107],"also":[108],"be":[109],"obtained.":[110],"algorithm":[113],"was":[114,123],"implemented":[115],"prototype":[118],"locator":[120],"installed":[124],"at":[125],"Celilo":[127],"Converter":[128],"Station":[129],"Pacific":[132,174],"Intertie":[134,176],"in":[135],"May":[136],"1984.":[137],"Over":[138],"six-month":[140],"field":[141],"evaluation":[142],"period,":[143],"we":[144],"obtained":[145],"six":[146],"dc":[147],"For":[149],"most":[150],"faults,":[153],"agreement":[155],"between":[156],"two-ended":[161],"system":[162],"within":[164],"half":[166],"mile":[167],"over":[168],"length":[170],"850-mile":[173],"transmission":[177]},"counts_by_year":[],"updated_date":"2026-10-02T10:15:12.560889","created_date":"2025-10-10T00:00:00"}