{"id":"https://openalex.org/W39169526","doi":null,"title":"Troubleshooting the video endoscopy system.","display_name":"Troubleshooting the video endoscopy system.","publication_year":1993,"publication_date":"1993-05-01","ids":{"openalex":"https://openalex.org/W39169526","mag":"39169526","pmid":"https://pubmed.ncbi.nlm.nih.gov/8322405"},"language":"en","primary_location":{"id":"pmid:8322405","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/8322405","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Today's OR nurse","raw_type":"Journal Article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040589690","display_name":"Robert T. Marousky","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"R T Marousky","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5040589690"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.00956023,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"15","issue":"3","first_page":"31","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9380000233650208,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9380000233650208,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.02250000089406967,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12744","display_name":"Medical Device Sterilization and Disinfection","score":0.013199999928474426,"subfield":{"id":"https://openalex.org/subfields/2404","display_name":"Microbiology"},"field":{"id":"https://openalex.org/fields/24","display_name":"Immunology and Microbiology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/videoendoscopy","display_name":"videoendoscopy","score":0.8939999938011169},{"id":"https://openalex.org/keywords/troubleshooting","display_name":"troubleshooting","score":0.609000027179718},{"id":"https://openalex.org/keywords/fiber-optic-light-source","display_name":"fiber optic light source","score":0.5680000185966492},{"id":"https://openalex.org/keywords/fiber-breakage","display_name":"fiber breakage","score":0.8059999942779541},{"id":"https://openalex.org/keywords/operating-room-nursing","display_name":"operating room nursing","score":0.609000027179718},{"id":"https://openalex.org/keywords/fire-hazard","display_name":"fire hazard","score":0.8529999852180481},{"id":"https://openalex.org/keywords/color-balance","display_name":"color balance","score":0.6930000185966492},{"id":"https://openalex.org/keywords/display-calibration","display_name":"display calibration","score":0.5799999833106995},{"id":"https://openalex.org/keywords/surgical-lighting","display_name":"surgical lighting","score":0.5460000038146973}],"concepts":[{"id":"https://openalex.org/C147494362","wikidata":"https://www.wikidata.org/wiki/Q2078905","display_name":"Troubleshooting","level":2,"score":0.9049727916717529},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6177948117256165},{"id":"https://openalex.org/C2778012447","wikidata":"https://www.wikidata.org/wiki/Q1034415","display_name":"Scope (computer science)","level":2,"score":0.5352540612220764},{"id":"https://openalex.org/C194232370","wikidata":"https://www.wikidata.org/wiki/Q162","display_name":"Optical fiber","level":2,"score":0.5117428302764893},{"id":"https://openalex.org/C2984065012","wikidata":"https://www.wikidata.org/wiki/Q23444","display_name":"White light","level":2,"score":0.4644384980201721},{"id":"https://openalex.org/C165005293","wikidata":"https://www.wikidata.org/wiki/Q1074500","display_name":"Chip","level":2,"score":0.4318055212497711},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.40176117420196533},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.3913893699645996},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.38112103939056396},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.2905700206756592},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.28087884187698364},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11414489150047302},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008283","descriptor_name":"Maintenance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014741","descriptor_name":"Video Recording","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D019723","descriptor_name":"Endoscopes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"pmid:8322405","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/8322405","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Today's OR nurse","raw_type":"Journal Article"},{"id":"mag:39169526","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/8322405","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"PubMed","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.428600013256073,"display_name":"Good health and well-being"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1507207627","https://openalex.org/W1770373984","https://openalex.org/W2141201813","https://openalex.org/W2889517514","https://openalex.org/W2960873236","https://openalex.org/W2981748178","https://openalex.org/W2999099744","https://openalex.org/W4239517556"],"related_works":["https://openalex.org/W2411449995","https://openalex.org/W4384151669","https://openalex.org/W2313164855","https://openalex.org/W2255872445","https://openalex.org/W169298765","https://openalex.org/W2038590165","https://openalex.org/W2014507905","https://openalex.org/W182231377","https://openalex.org/W2949526289","https://openalex.org/W2531860724"],"abstract_inverted_index":{"1.":[0],"OR":[1],"nurses":[2],"must":[3,120,132],"be":[4,67,107,121,133],"alert":[5],"to":[6,91,124,128,136,140],"the":[7,12,16,19,25,28,33,42,58,63,73,76,116,126,130,138,143],"problem":[8],"of":[9,11,21,30],"breakage":[10],"light-carrying":[13],"fibers":[14,23],"inside":[15],"scope.":[17],"As":[18],"number":[20],"intact":[22],"in":[24,37],"bundle":[26],"decreases,":[27,35],"amount":[29],"light":[31,92],"through":[32],"scope":[34,59],"resulting":[36],"an":[38],"unsatisfactory":[39],"picture":[40],"on":[41,62,142],"monitor.":[43],"2.":[44],"Fiber-optic":[45],"lights,":[46,49],"like":[47],"surgical":[48,64],"are":[50,87,95],"very":[51],"hot.":[52],"A":[53],"fiber-optic":[54],"cable":[55],"disconnected":[56],"from":[57],"but":[60],"left":[61],"field":[65],"can":[66],"a":[68],"fire":[69],"hazard.":[70],"3.":[71],"Evaluate":[72],"system":[74],"using":[75],"actual":[77],"components":[78],"before":[79],"purchase.":[80],"Three-chip":[81],"cameras":[82],"offer":[83],"better":[84],"resolution":[85],"than,":[86],"not":[88,106],"as":[89,115],"sensitive":[90],"as,":[93],"and":[94],"more":[96],"expensive":[97],"than":[98],"single-chip":[99],"cameras.":[100],"However,":[101],"their":[102],"higher":[103],"cost":[104],"may":[105],"justifiable":[108],"for":[109],"your":[110],"operating":[111],"room.":[112],"4.":[113],"Just":[114],"camera":[117],"control":[118],"unit":[119],"white":[122],"balanced":[123,135],"know":[125,137],"colors":[127,139],"transmit,":[129],"monitor":[131],"color":[134],"show":[141],"screen.":[144]},"counts_by_year":[],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
