{"id":"https://openalex.org/W37685113","doi":null,"title":"Effect of ground-grid changes on control-cable voltages at Bruce NGS B. Report No. 90-141-K","display_name":"Effect of ground-grid changes on control-cable voltages at Bruce NGS B. Report No. 90-141-K","publication_year":1990,"publication_date":"1990-01-01","ids":{"openalex":"https://openalex.org/W37685113","mag":"37685113"},"language":"en","primary_location":{"id":"mag:37685113","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5575921-effect-ground-grid-changes-control-cable-voltages-bruce-ngs-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111754631","display_name":"S.M. Harvey","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S.M. Harvey","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5029881730","display_name":"Erik Dick","orcid":"https://orcid.org/0000-0001-8966-3481","observed_orcids":["https://orcid.org/0000-0001-8966-3481"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Erik Dick","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-8966-3481","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.00366356,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.9717000126838684,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.9717000126838684,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.018200000748038292,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.002300000051036477,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ground-potential-difference","display_name":"ground potential difference","score":0.6499999761581421},{"id":"https://openalex.org/keywords/standby-generators","display_name":"standby generators","score":0.6150000095367432},{"id":"https://openalex.org/keywords/lightning-induced-faults","display_name":"lightning-induced faults","score":0.5920000076293945},{"id":"https://openalex.org/keywords/thunderstorms","display_name":"thunderstorms","score":0.5669999718666077},{"id":"https://openalex.org/keywords/electrical-faults","display_name":"electrical faults","score":0.35199999809265137},{"id":"https://openalex.org/keywords/field-testing","display_name":"field testing","score":0.31299999356269836}],"concepts":[{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.7150636911392212},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5981670618057251},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.5734633207321167},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.5470833778381348},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.5370925664901733},{"id":"https://openalex.org/C2780505938","wikidata":"https://www.wikidata.org/wiki/Q17093282","display_name":"Unavailability","level":2,"score":0.5341694951057434},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4729616045951843},{"id":"https://openalex.org/C86132830","wikidata":"https://www.wikidata.org/wiki/Q3308838","display_name":"Outflow","level":2,"score":0.47020038962364197},{"id":"https://openalex.org/C80316258","wikidata":"https://www.wikidata.org/wiki/Q2857578","display_name":"Thunderstorm","level":2,"score":0.42834410071372986},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.22846952080726624},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15182802081108093},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.10420197248458862}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:37685113","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5575921-effect-ground-grid-changes-control-cable-voltages-bruce-ngs-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4943999946117401,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320323959","display_name":"University of Johannesburg","ror":"https://ror.org/04z6c2n17"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2079094333","https://openalex.org/W1582277561","https://openalex.org/W1561603377","https://openalex.org/W2022703458","https://openalex.org/W7097430851","https://openalex.org/W3204032370","https://openalex.org/W2353872623","https://openalex.org/W3217091030","https://openalex.org/W3020907553","https://openalex.org/W2384638301"],"abstract_inverted_index":{"On":[0],"August":[1],"4th":[2],"and":[3,14,21,42,56,63,67,73,125,129],"October":[4],"15th,":[5],"1989,":[6],"while":[7],"thunderstorms":[8],"were":[9],"in":[10,30],"progress,":[11],"numerous":[12],"electrical":[13],"instrumentation":[15],"faults":[16],"appeared":[17,51],"on":[18,45,120,126,132],"units":[19],"0":[20],"5":[22],"of":[23,34,80,89,115],"Bruce":[24],"Nuclear":[25],"Generating":[26],"Station":[27],"B,":[28],"resulting":[29],"the":[31,54,61,71,77,81,87,96,102,113,121,127],"temporary":[32],"unavailability":[33],"critical":[35],"standby":[36,64],"generators,":[37],"unwarranted":[38],"station":[39,97],"service":[40],"transfers,":[41],"fuse":[43],"blowing":[44],"DC":[46],"supply":[47],"wiring.":[48],"An":[49],"investigation":[50],"to":[52,95,111],"implicate":[53],"control":[55],"annunciation":[57],"cables":[58],"running":[59],"between":[60,70],"powerhouse":[62],"generators":[65],"SG5":[66],"SG6":[68],"located":[69],"intake":[72],"outflow":[74],"channels":[75],"at":[76],"south":[78],"end":[79],"station.":[82],"It":[83],"was":[84],"hypothesized":[85],"that":[86],"installation":[88],"additional,":[90],"appropriately":[91],"placed,":[92],"bonding":[93,118],"conductors":[94,119],"ground":[98,122],"mat":[99],"could":[100],"alleviate":[101],"problem.":[103],"This":[104],"report":[105],"describes":[106],"some":[107],"field":[108],"tests":[109],"performed":[110],"determine":[112],"effect":[114],"adding":[116],"additional":[117],"potential":[123],"difference":[124],"voltages":[128],"currents":[130],"appearing":[131],"a":[133],"selected":[134],"cable.":[135]},"counts_by_year":[],"updated_date":"2026-08-08T07:41:36.138363","created_date":"2016-06-24T00:00:00"}