{"id":"https://openalex.org/W37157512","doi":null,"title":"A Study on Compression Characteristic of Wet Vapor Refrigerant","display_name":"A Study on Compression Characteristic of Wet Vapor Refrigerant","alternate_titles":[],"publication_year":1996,"publication_date":"1996-01-01","ids":{"openalex":"https://openalex.org/W37157512","mag":"37157512"},"language":"en","primary_location":{"id":"pmh:oai:docs.lib.purdue.edu:icec-2111","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/icec/1112","pdf_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2111&context=icec","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Compressor Engineering Conference","raw_type":"text"},"parent_works":[],"lineage":["https://openalex.org/W37157512"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2111&context=icec","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085854162","display_name":"Asit K. Dutta","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Asit K. Dutta","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034104445","display_name":"T. Yanagisawa","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"T. Yanagisawa","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5088449790","display_name":"Mitsuhiro Fukuta","orcid":"https://orcid.org/0000-0001-9749-1173","observed_orcids":["https://orcid.org/0000-0001-9749-1173"]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Mitsuhiro Fukuta","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":22,"citation_normalized_percentile":{"value":0.00708383,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10850","display_name":"Heat Transfer and Boiling Studies","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12139","display_name":"Advanced Thermodynamic Systems and Engines","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reciprocating-compressor","display_name":"reciprocating compressor","score":0.7760000228881836},{"id":"https://openalex.org/keywords/compression-characteristics","display_name":"compression characteristics","score":0.7490000128746033},{"id":"https://openalex.org/keywords/liquid-slugs","display_name":"liquid slugs","score":0.6029999852180481},{"id":"https://openalex.org/keywords/homogeneous-mixture-model","display_name":"homogeneous mixture model","score":0.6980000138282776},{"id":"https://openalex.org/keywords/droplet-size","display_name":"droplet size","score":0.9100000262260437},{"id":"https://openalex.org/keywords/cylinder-wall-heat-transfer","display_name":"cylinder wall heat transfer","score":0.8899999856948853},{"id":"https://openalex.org/keywords/refrigeration-cycle","display_name":"refrigeration cycle","score":0.8259999752044678}],"concepts":[{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.7613961100578308},{"id":"https://openalex.org/C2780934780","wikidata":"https://www.wikidata.org/wiki/Q7542251","display_name":"Slugging","level":3,"score":0.7232722043991089},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.6061649322509766},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.5723156929016113},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.5673477053642273},{"id":"https://openalex.org/C36570524","wikidata":"https://www.wikidata.org/wiki/Q615475","display_name":"Vapor-compression refrigeration","level":4,"score":0.5180378556251526},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.5097364783287048},{"id":"https://openalex.org/C142176979","wikidata":"https://www.wikidata.org/wiki/Q5157020","display_name":"Compressed fluid","level":2,"score":0.4920927882194519},{"id":"https://openalex.org/C180016635","wikidata":"https://www.wikidata.org/wiki/Q2712821","display_name":"Compression (physics)","level":2,"score":0.4871082305908203},{"id":"https://openalex.org/C116148737","wikidata":"https://www.wikidata.org/wiki/Q783618","display_name":"Vapor quality","level":4,"score":0.4772591292858124},{"id":"https://openalex.org/C5395353","wikidata":"https://www.wikidata.org/wiki/Q2265508","display_name":"Reciprocating compressor","level":3,"score":0.4653511643409729},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4494103491306305},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.32146790623664856},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.16335615515708923},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.07765108346939087},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:docs.lib.purdue.edu:icec-2111","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/icec/1112","pdf_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2111&context=icec","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Compressor Engineering Conference","raw_type":"text"},{"id":"mag:37157512","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2111&context=icec","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:docs.lib.purdue.edu:icec-2111","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/icec/1112","pdf_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2111&context=icec","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Compressor Engineering Conference","raw_type":"text"},"sustainable_development_goals":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G6526067454","display_name":null,"funder_award_id":"2020A1515010634","funder_id":"https://openalex.org/F4320321921","funder_display_name":"Natural Science Foundation of Guangdong Province"}],"funders":[{"id":"https://openalex.org/F4320321921","display_name":"Natural Science Foundation of Guangdong Province","ror":null}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W37157512.pdf","grobid_xml":"https://content.openalex.org/works/W37157512.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W1542464309"],"related_works":["https://openalex.org/W2335051038","https://openalex.org/W2089314723","https://openalex.org/W3004071355","https://openalex.org/W1544288628","https://openalex.org/W4224273423","https://openalex.org/W59376566","https://openalex.org/W773149775","https://openalex.org/W7056683659","https://openalex.org/W2980002486","https://openalex.org/W1585743359"],"abstract_inverted_index":{"In":[0],"this":[1,125,173],"study":[2],"a":[3,141,150],"compression":[4,113,118],"characteristic":[5],"of":[6,21,30,35,43,48,53,81,92,129,177,194],"vapor":[7,36,55,182],"-liquid":[8,183],"two":[9],"phase":[10],"refrigerant":[11,95,106],"mixture":[12,23,184],"is":[13],"analyzed":[14],"theoretically":[15],"by":[16,77,103,148],"using":[17,78,149],"the":[18,27,31,40,44,49,57,62,68,79,82,88,93,108,112,116,127,130,138,157,175,178,186,199],"mathematical":[19],"models":[20],"vapor-liquid":[22],"condition":[24,91],"in":[25],"which":[26],"droplet":[28],"size":[29,189],"liquid,":[32],"homogeneous":[33,181],"mix.'Wre":[34],"and":[37,39,56,115,156],"liquid_":[38],"slugging":[41,133],"concept":[42,134],"liquid":[45,94,98,105,154,195],"are":[46,70,169],"considered.Influences":[47],"parameters.such":[50],"as":[51,64,66,97],"quality":[52,168],"wet":[54],"cylinder":[58,109,158],"wall":[59],"heat":[60],"transfer.on":[61],"pressure":[63,159],"well":[65,136,197],"on":[67],"temperature":[69],"investigated.A":[71],"model":[72,131,179],"experiment":[73,144],"has":[74,100,120,145],"been":[75,101,121,146],"done":[76,147],"components":[80],"reciprocating":[83,151],"compressor":[84,152],"\"'ithout":[85],"connecting":[86],"to":[87,111],"refrigeration":[89,142],"cycle.Different":[90],"such":[96],"slug":[99],"created":[102],"injecting":[104],"into":[107],"prior":[110],"start,":[114],"first":[117],"process":[119],"considered":[122],"for":[123,171],"investigation.In":[124,172],"case,":[126,174],"result":[128,176],"considering":[132,180],"matches":[135,196],"\u2022vith":[137,165],"experimental":[139,200],"result.Further.":[140],"cycle":[143],"under":[153],"suctioning,":[155],"change":[160],"at":[161],"steady":[162],"state":[163],"operation":[164],"different":[166],"suction":[167],"recorded":[170],"or":[185],"smallest":[187],"drop":[188],"(":[190],"l":[191],"f.L":[192],"11V":[193],"with":[198],"result.":[201]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W37157512","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
