{"id":"https://openalex.org/W36640260","doi":null,"title":"Modeling of short circuit fault arc in 150 kV system and its influence on the performance of distance protection","display_name":"Modeling of short circuit fault arc in 150 kV system and its influence on the performance of distance protection","publication_year":2009,"publication_date":"2009-07-10","ids":{"openalex":"https://openalex.org/W36640260","mag":"36640260"},"language":"en","primary_location":{"id":"pmh:oai:tudelft.nl:uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","doi":null,"is_oa":true,"landing_page_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","pdf_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","source":{"id":"https://openalex.org/S4306400906","display_name":"Research Repository (Delft University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I98358874","host_organization_name":"Delft University of Technology","host_organization_lineage":["https://openalex.org/I98358874"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"master thesis"},"volume":null,"type":"dissertation","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5074046366","display_name":"Handy Wihartady","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"H. Wihartady","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5074046366"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":5,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0012000000569969416,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/150-kv-transmission-line","display_name":"150 kV transmission line","score":0.8489999771118164},{"id":"https://openalex.org/keywords/distance-protection","display_name":"distance protection","score":0.8109999895095825},{"id":"https://openalex.org/keywords/single-line-to-ground-fault","display_name":"single-phase grounding fault","score":0.8450000286102295},{"id":"https://openalex.org/keywords/arc-parameters","display_name":"arc parameters","score":0.7369999885559082},{"id":"https://openalex.org/keywords/impedance-extraction","display_name":"impedance extraction","score":0.7110000252723694}],"concepts":[{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.811187744140625},{"id":"https://openalex.org/C83415579","wikidata":"https://www.wikidata.org/wiki/Q161973","display_name":"Arc (geometry)","level":2,"score":0.6217479109764099},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6053705811500549},{"id":"https://openalex.org/C212702","wikidata":"https://www.wikidata.org/wiki/Q178150","display_name":"Insulator (electricity)","level":2,"score":0.5976548790931702},{"id":"https://openalex.org/C200769187","wikidata":"https://www.wikidata.org/wiki/Q2360656","display_name":"Arc flash","level":3,"score":0.5924105644226074},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5780590772628784},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.573489248752594},{"id":"https://openalex.org/C157069517","wikidata":"https://www.wikidata.org/wiki/Q132172","display_name":"Arc-fault circuit interrupter","level":4,"score":0.5444425940513611},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5354336500167847},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4926820397377014},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4915519654750824},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.48882338404655457},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4633301794528961},{"id":"https://openalex.org/C167391956","wikidata":"https://www.wikidata.org/wiki/Q1401211","display_name":"Fault model","level":3,"score":0.43057870864868164},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.42772141098976135},{"id":"https://openalex.org/C114375839","wikidata":"https://www.wikidata.org/wiki/Q207456","display_name":"Electric arc","level":3,"score":0.4222124218940735},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41290023922920227},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4101761281490326},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.34739309549331665},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.3414287567138672},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2916567921638489},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.24874192476272583},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1557859182357788},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.13811925053596497},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.12124267220497131},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.11139506101608276},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.08478331565856934},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"pmh:oai:tudelft.nl:uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","doi":null,"is_oa":true,"landing_page_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","pdf_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","source":{"id":"https://openalex.org/S4306400906","display_name":"Research Repository (Delft University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I98358874","host_organization_name":"Delft University of Technology","host_organization_lineage":["https://openalex.org/I98358874"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"master thesis"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.1014.1156","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1014.1156","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://repository.tudelft.nl/assets/uuid%3A57b83904-ac5e-467b-bce9-5b50a3d48c5b/Wihartady_Final_Draft_New.pdf","raw_type":"text"},{"id":"mag:36640260","doi":null,"is_oa":false,"landing_page_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:tudelft.nl:uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","doi":null,"is_oa":true,"landing_page_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","pdf_url":"http://resolver.tudelft.nl/uuid:57b83904-ac5e-467b-bce9-5b50a3d48c5b","source":{"id":"https://openalex.org/S4306400906","display_name":"Research Repository (Delft University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I98358874","host_organization_name":"Delft University of Technology","host_organization_lineage":["https://openalex.org/I98358874"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"master thesis"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321012","display_name":"Technische Universiteit Delft","ror":"https://ror.org/02e2c7k09"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W36640260.pdf","grobid_xml":"https://content.openalex.org/works/W36640260.grobid-xml"},"referenced_works_count":50,"referenced_works":["https://openalex.org/W582099597","https://openalex.org/W582604531","https://openalex.org/W1534934467","https://openalex.org/W1598882096","https://openalex.org/W1804986381","https://openalex.org/W1967142870","https://openalex.org/W1986234170","https://openalex.org/W1990253071","https://openalex.org/W1992606175","https://openalex.org/W2011241671","https://openalex.org/W2018912420","https://openalex.org/W2029652003","https://openalex.org/W2033254113","https://openalex.org/W2054828149","https://openalex.org/W2055781799","https://openalex.org/W2057559671","https://openalex.org/W2067196635","https://openalex.org/W2074673996","https://openalex.org/W2075394689","https://openalex.org/W2097259163","https://openalex.org/W2104817427","https://openalex.org/W2112317021","https://openalex.org/W2121822802","https://openalex.org/W2127389410","https://openalex.org/W2134333608","https://openalex.org/W2163373876","https://openalex.org/W2169767142","https://openalex.org/W2254981042","https://openalex.org/W2523989131","https://openalex.org/W2525459565","https://openalex.org/W2591655379","https://openalex.org/W2737693282","https://openalex.org/W2762142383","https://openalex.org/W2763110114","https://openalex.org/W2888447333","https://openalex.org/W2889322279","https://openalex.org/W2901951820","https://openalex.org/W2903555655","https://openalex.org/W2911198183","https://openalex.org/W2915580372","https://openalex.org/W2919709190","https://openalex.org/W2984000721","https://openalex.org/W3008301586","https://openalex.org/W3044495713","https://openalex.org/W3086534983","https://openalex.org/W3103761932","https://openalex.org/W3118314061","https://openalex.org/W3135274425","https://openalex.org/W6665680189","https://openalex.org/W6745806763"],"related_works":["https://openalex.org/W2377811652","https://openalex.org/W2029652003","https://openalex.org/W4407627798","https://openalex.org/W4398786068","https://openalex.org/W3110648289","https://openalex.org/W1993284933","https://openalex.org/W2127389410","https://openalex.org/W4413530868","https://openalex.org/W2123632376","https://openalex.org/W2359060457"],"abstract_inverted_index":{"The":[0,79],"short":[1],"circuit":[2],"arc":[3,71,96,109],"is":[4,53,72],"the":[5,10,36,63,67,69,75,88,92,105,107],"most":[6],"dominant":[7],"fault":[8,48,70],"in":[9,26,35,50,74,113,127,134],"power":[11],"system":[12,25,52],"that":[13,51],"leads":[14],"to":[15,18,90,117],"single":[16],"phase":[17],"ground":[19],"fault.":[20],"South":[21],"Sumatera":[22],"150":[23],"kV":[24],"Indonesia":[27],"consists":[28],"of":[29,66,101],"two":[30,99],"different":[31,114],"string":[32,102],"insulator":[33],"types":[34,100],"transmission":[37],"line,":[38],"with":[39,87],"and":[40,81,94,131],"without":[41],"arching":[42],"horn.":[43],"In":[44],"this":[45],"study,":[46],"some":[47],"situations":[49],"reconstructed":[54],"by":[55,123],"using":[56,124],"ATP":[57],"Draw":[58],"\u2013":[59],"EMTP":[60],"software.":[61],"As":[62],"main":[64],"part":[65],"simulation,":[68],"represented":[73],"MODELS":[76],"language":[77],"form.":[78],"voltage":[80],"current":[82],"terminal":[83],"results":[84],"are":[85,111],"compared":[86],"measurements":[89],"obtain":[91],"primary":[93],"secondary":[95],"parameter":[97],"for":[98],"insulator.":[103],"At":[104],"end,":[106],"fix":[108],"models":[110],"used":[112],"simulation":[115],"cases":[116],"evaluate":[118],"existing":[119],"distance":[120],"protection":[121],"setting":[122],"impedance":[125],"extraction":[126],"ISA":[128],"TDMS":[129],"software":[130],"recursive":[132],"DFS":[133],"MODELS.":[135]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2016-06-24T00:00:00"}