{"id":"https://openalex.org/W3217537707","doi":null,"title":"Modelling and Simulation of Fault Distance Locator for Underground Cable Detection","display_name":"Modelling and Simulation of Fault Distance Locator for Underground Cable Detection","alternate_titles":[],"publication_year":2021,"publication_date":"2021-11-15","ids":{"openalex":"https://openalex.org/W3217537707","mag":"3217537707"},"language":"en","primary_location":{"id":"mag:3217537707","doi":null,"is_oa":false,"landing_page_url":"https://publisher.uthm.edu.my/periodicals/index.php/eeee/article/view/4583","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Evolution in Electrical and Electronic Engineering","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W3217537707"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067983131","display_name":"Nursharina Ahmad","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Nursharina Ahmad","raw_affiliation_strings":["FKEEUTHM"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"FKEEUTHM","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027215732","display_name":"Dirman Hanafi","orcid":"https://orcid.org/0000-0002-5766-8605","observed_orcids":["https://orcid.org/0000-0002-5766-8605"]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Dirman Hanafi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1766,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.36369074,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":92},"biblio":{"volume":"2","issue":"2","first_page":"876","last_page":"884"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wavelet-analysis","display_name":"wavelet analysis","score":0.953000009059906},{"id":"https://openalex.org/keywords/neural-network","display_name":"artificial neural networks","score":0.9629999995231628},{"id":"https://openalex.org/keywords/power-distribution-networks","display_name":"power distribution networks","score":0.7409999966621399},{"id":"https://openalex.org/keywords/single-line-to-ground-fault","display_name":"single-phase grounding fault","score":0.7260000109672546},{"id":"https://openalex.org/keywords/ieee-13-bus-system","display_name":"IEEE 13-bus system","score":0.8059999942779541},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.3440000116825104}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7375859022140503},{"id":"https://openalex.org/C2777772068","wikidata":"https://www.wikidata.org/wiki/Q1939150","display_name":"Power cable","level":3,"score":0.5918594002723694},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.555112361907959},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5357145071029663},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.5321720242500305},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5237255692481995},{"id":"https://openalex.org/C47432892","wikidata":"https://www.wikidata.org/wiki/Q831390","display_name":"Wavelet","level":2,"score":0.5104516744613647},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45185035467147827},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.4378514289855957},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.4369598925113678},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.43227052688598633},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41553449630737305},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.37055253982543945},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35279035568237305},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.34547826647758484},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.27040401101112366},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.20289179682731628},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.18291303515434265},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09582686424255371},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.09339874982833862},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0741666853427887},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2779227376","wikidata":"https://www.wikidata.org/wiki/Q6505497","display_name":"Layer (electronics)","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:3217537707","doi":null,"is_oa":false,"landing_page_url":"https://publisher.uthm.edu.my/periodicals/index.php/eeee/article/view/4583","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Evolution in Electrical and Electronic Engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2984831710","https://openalex.org/W3202637455","https://openalex.org/W4230682269","https://openalex.org/W2584529837","https://openalex.org/W2367454275","https://openalex.org/W4233217579","https://openalex.org/W2901475400","https://openalex.org/W4233817822","https://openalex.org/W2105611071","https://openalex.org/W7219181523"],"abstract_inverted_index":{"Underground":[0],"cables":[1],"have":[2],"been":[3],"widely":[4],"employed":[5],"for":[6,10,213],"power":[7],"distribution":[8],"networks":[9],"hundreds":[11],"of":[12,17,30,51,78,90,96,130,183,196,219],"years.":[13],"Meanwhile,":[14,202],"the":[15,27,41,49,85,93,115,156,203],"preponderance":[16],"underground":[18,54,98,104],"faults":[19,52,91],"is":[20,37,45,81,107,172,185,211],"detected":[21],"by":[22],"excavating":[23],"and":[24,66,87,123,144,158,166,180,205],"approach":[25],"known":[26],"entire":[28,42],"length":[29,44],"armoured":[31],"cable.":[32],"If":[33],"a":[34,192,216],"visual":[35],"check":[36],"still":[38],"not":[39],"practicable,":[40],"cable":[43,99,105],"replaced.":[46],"To":[47],"address":[48],"issue":[50],"in":[53,162,187,208],"cables,":[55],"this":[56,79],"project":[57],"will":[58],"use":[59],"wavelet":[60,160],"analysis":[61],"to":[62,72,83,108,134,140,147],"detect":[63,84],"fault":[64,74,136,142,149,171,195],"locations":[65],"an":[67,97],"artificial":[68],"neural":[69],"network":[70],"(ANN)":[71],"evaluate":[73],"performance.":[75],"The":[76,103,151,178],"objective":[77],"method":[80],"utilized":[82],"point":[86],"distance":[88,169,193,217],"location":[89],"from":[92,175,199,222],"source":[94],"end":[95],"through":[100],"transmission":[101],"line.":[102],"system":[106],"designed":[109],"with":[110,168,191,215],"MATLAB":[111],"Simulink":[112],"based":[113],"on":[114],"IEEE":[116],"bus":[117,176,200,223],"system,":[118],"which":[119],"has":[120],"13":[121],"buses":[122],"16":[124],"lines.":[125],"There":[126],"are":[127],"three":[128,145],"types":[129],"faults:":[131],"single":[132],"phase":[133,139,146],"earth":[135,141,148],"(LG),":[137],"double":[138],"(LLG),":[143],"(LLLG).":[150],"simulation":[152],"results":[153],"show":[154],"that":[155],"voltage":[157,179,204],"current":[159,181,206],"delaying":[161,207],"onset":[163,188,209],"at":[164,189],"1.37ms":[165],"1.66ms":[167],"(D)":[170,194,218],"2.886":[173],"km":[174,198,221],"4.":[177],"wavelets":[182],"LLG":[184],"delayed":[186],"1.36ms":[190],"16.223":[197],"9.":[201],"1.35ms":[210],"observed":[212],"LLLG":[214],"2.499":[220],"8.":[224]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W3217537707","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2021-12-06T00:00:00"}
