{"id":"https://openalex.org/W3204903348","doi":"https://doi.org/10.1080/15567036.2021.1982076","title":"Experimental investigation on the effect of expansion valves in a dual evaporator ejector refrigeration system using R134a and R456a","display_name":"Experimental investigation on the effect of expansion valves in a dual evaporator ejector refrigeration system using R134a and R456a","publication_year":2021,"publication_date":"2021-09-28","ids":{"openalex":"https://openalex.org/W3204903348","doi":"https://doi.org/10.1080/15567036.2021.1982076","mag":"3204903348"},"language":"en","primary_location":{"id":"doi:10.1080/15567036.2021.1982076","doi":"https://doi.org/10.1080/15567036.2021.1982076","is_oa":false,"landing_page_url":"https://doi.org/10.1080/15567036.2021.1982076","pdf_url":null,"source":{"id":"https://openalex.org/S4210188153","display_name":"Energy Sources Part A Recovery Utilization and Environmental Effects","issn_l":"1556-7036","issn":["1556-7036","1556-7230"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-40","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Sources, Part A: Recovery, Utilization, and Environmental Effects","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5066100732","display_name":"\u00dcmit \u0130\u015fkan","orcid":"https://orcid.org/0000-0001-6236-2339","observed_orcids":["https://orcid.org/0000-0001-6236-2339"]},"institutions":[{"id":"https://openalex.org/I40790370","display_name":"Yalova University","ror":"https://ror.org/01x18ax09","country_code":"TR","type":"education","lineage":["https://openalex.org/I40790370"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"\u00dcmit I\u015fkan","raw_affiliation_strings":["Yalova University","Faculty of Engineering, Department of Energy Systems Engineering, Yalova University, Yalova, Turkey","Institute of Graduate Studies, Department of Energy Systems Engineering, Yalova University, Yalova, Turkey"],"raw_orcid":"https://orcid.org/0000-0001-6236-2339","affiliations":[{"raw_affiliation_string":"Yalova University","institution_ids":["https://openalex.org/I40790370"]},{"raw_affiliation_string":"Faculty of Engineering, Department of Energy Systems Engineering, Yalova University, Yalova, Turkey","institution_ids":["https://openalex.org/I40790370"]},{"raw_affiliation_string":"Institute of Graduate Studies, Department of Energy Systems Engineering, Yalova University, Yalova, Turkey","institution_ids":["https://openalex.org/I40790370"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5014198740","display_name":"Mehmet Direk","orcid":"https://orcid.org/0000-0001-5868-6381","observed_orcids":["https://orcid.org/0000-0001-5868-6381"]},"institutions":[{"id":"https://openalex.org/I40790370","display_name":"Yalova University","ror":"https://ror.org/01x18ax09","country_code":"TR","type":"education","lineage":["https://openalex.org/I40790370"]}],"countries":["TR"],"is_corresponding":true,"raw_author_name":"Mehmet Direk","raw_affiliation_strings":["Yalova University","Faculty of Engineering, Department of Energy Systems Engineering, Yalova University, Yalova, Turkey"],"raw_orcid":"https://orcid.org/0000-0001-5868-6381","affiliations":[{"raw_affiliation_string":"Yalova University","institution_ids":["https://openalex.org/I40790370"]},{"raw_affiliation_string":"Faculty of Engineering, Department of Energy Systems Engineering, Yalova University, Yalova, Turkey","institution_ids":["https://openalex.org/I40790370"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5014198740"],"corresponding_institution_ids":["https://openalex.org/I40790370"],"apc_list":null,"apc_paid":null,"fwci":0.7512,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.63690632,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"47","issue":"1","first_page":"2364","last_page":"2378"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10568","display_name":"Thermodynamic and Exergetic Analyses of Power and Cooling Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/expansion-valve","display_name":"expansion valve","score":0.8730000257492065},{"id":"https://openalex.org/keywords/thermostatic-expansion-valve","display_name":"thermostatic expansion valve","score":0.9459999799728394},{"id":"https://openalex.org/keywords/r-134a","display_name":"R134a","score":0.8019999861717224},{"id":"https://openalex.org/keywords/entrainment-ratio","display_name":"entrainment ratio","score":0.9869999885559082},{"id":"https://openalex.org/keywords/coefficient-of-performance","display_name":"coefficient of performance","score":0.8500000238418579},{"id":"https://openalex.org/keywords/cooling-capacity","display_name":"cooling capacity","score":0.9919999837875366},{"id":"https://openalex.org/keywords/alternative-refrigerants","display_name":"alternative refrigerants","score":0.7149999737739563},{"id":"https://openalex.org/keywords/ejector-refrigeration","display_name":"ejector refrigeration","score":0.7609999775886536}],"concepts":[{"id":"https://openalex.org/C184593036","wikidata":"https://www.wikidata.org/wiki/Q279421","display_name":"Thermal expansion valve","level":4,"score":0.9026780724525452},{"id":"https://openalex.org/C91311341","wikidata":"https://www.wikidata.org/wiki/Q1764892","display_name":"Evaporator","level":3,"score":0.8833644390106201},{"id":"https://openalex.org/C135186712","wikidata":"https://www.wikidata.org/wiki/Q425705","display_name":"Injector","level":2,"score":0.8243943452835083},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.7378931045532227},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.6453768014907837},{"id":"https://openalex.org/C125557594","wikidata":"https://www.wikidata.org/wiki/Q1796972","display_name":"Refrigerator car","level":2,"score":0.5768092274665833},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.562265932559967},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.4774268567562103},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.47736120223999023},{"id":"https://openalex.org/C61441594","wikidata":"https://www.wikidata.org/wiki/Q132814","display_name":"Evaporation","level":2,"score":0.4612084925174713},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4195926785469055},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.4118221700191498},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.34145426750183105},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2151343822479248},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17763090133666992},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.06097114086151123}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/15567036.2021.1982076","doi":"https://doi.org/10.1080/15567036.2021.1982076","is_oa":false,"landing_page_url":"https://doi.org/10.1080/15567036.2021.1982076","pdf_url":null,"source":{"id":"https://openalex.org/S4210188153","display_name":"Energy Sources Part A Recovery Utilization and Environmental Effects","issn_l":"1556-7036","issn":["1556-7036","1556-7230"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-40","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Sources, Part A: Recovery, Utilization, and Environmental Effects","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G4284139996","display_name":null,"funder_award_id":"2020/YL/0006","funder_id":"https://openalex.org/F4320318288","funder_display_name":"Yalova \u00dcniversitesi"},{"id":"https://openalex.org/G7209557132","display_name":null,"funder_award_id":"2019/AP/0013","funder_id":"https://openalex.org/F4320318288","funder_display_name":"Yalova \u00dcniversitesi"}],"funders":[{"id":"https://openalex.org/F4320318288","display_name":"Yalova \u00dcniversitesi","ror":"https://ror.org/01x18ax09"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1585799852","https://openalex.org/W1971147868","https://openalex.org/W2000945154","https://openalex.org/W2041324041","https://openalex.org/W2045279920","https://openalex.org/W2048028872","https://openalex.org/W2056754315","https://openalex.org/W2073317744","https://openalex.org/W2330108082","https://openalex.org/W2470223166","https://openalex.org/W2470379299","https://openalex.org/W2544552850","https://openalex.org/W2594331020","https://openalex.org/W2774412694","https://openalex.org/W2886130381","https://openalex.org/W2942985268","https://openalex.org/W2988343735","https://openalex.org/W3004551455","https://openalex.org/W3018313528","https://openalex.org/W3080362290","https://openalex.org/W3128267778","https://openalex.org/W3167793748"],"related_works":["https://openalex.org/W4226334789","https://openalex.org/W4281633279","https://openalex.org/W4386334208","https://openalex.org/W4281262648","https://openalex.org/W1585733251","https://openalex.org/W2158253558","https://openalex.org/W2271242188","https://openalex.org/W7203480690","https://openalex.org/W4289545200","https://openalex.org/W4400164912"],"abstract_inverted_index":{"The":[0,79],"purpose":[1],"of":[2,26,83,103,109,137,205,211],"this":[3],"study":[4],"was":[5,35,46,59,73,95,114,125,142,175,199],"to":[6,22,160,177,180,209],"experimentally":[7],"investigate":[8],"a":[9,62,148],"dual":[10,49,223],"evaporator":[11,194,224],"ejector":[12],"system":[13,72,85,113],"(DEES)":[14],"operating":[15],"with":[16,48,61,75,227],"R134a":[17,76,124],"and":[18,77,107],"R456a.":[19,78],"In":[20,41,54,68,139],"order":[21],"see":[23],"the":[24,30,32,42,55,71,84,90,112,118,134,145,152,162,165,192,202],"effect":[25,150],"expansion":[27,51,65],"valves":[28,52],"in":[29,37,101,170,182,191,195,222],"system,":[31],"experimental":[33],"setup":[34],"arranged":[36],"two":[38],"different":[39],"configurations.":[40,172],"first":[43],"configuration,":[44,57],"DEES":[45,58,163],"operated":[47,60,115],"thermostatic":[50,64],"(DEES-DTXV).":[53],"second":[56],"single":[63],"valve":[66],"(DEES-STXV).":[67],"both":[69,171],"configurations,":[70],"tested":[74],"effective":[80],"performance":[81,203],"values":[82,204],"were":[86,207],"investigated":[87],"based":[88],"on":[89,151],"entrainment":[91],"ratios":[92],"(ERs).":[93],"It":[94],"found":[96,143,176,200],"that":[97,129,144,183,201],"DEES-STXV":[98,181],"outperformed":[99],"DEES-DTXV":[100,174],"terms":[102],"total":[104,119],"cooling":[105,120,153],"capacity":[106,121],"coefficient":[108],"performance.":[110],"When":[111],"as":[116,218],"DEES-STXV,":[117],"obtained":[122,130],"from":[123,131],"14%":[126],"higher":[127],"than":[128,168],"R456a":[132,206,214],"at":[133,164],"ER":[135],"value":[136],"0.5.":[138],"addition,":[140],"it":[141,156,198],"ERs":[146,166],"had":[147],"significant":[149],"capacities;":[154],"therefore,":[155],"is":[157],"not":[158],"recommended":[159],"operate":[161],"greater":[167],"0.8":[169],"Moreover,":[173],"be":[178,189,216],"superior":[179],"very":[184],"low":[185],"evaporation":[186],"temperatures":[187],"could":[188],"achieved":[190],"secondary":[193],"DEES-DTXV.":[196],"Finally,":[197],"close":[208],"those":[210],"R134a;":[212],"so,":[213],"can":[215],"used":[217],"an":[219],"alternative":[220],"refrigerant":[221],"refrigeration":[225],"systems":[226],"ejector.":[228]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":4}],"updated_date":"2026-09-05T08:02:43.246662","created_date":"2021-10-11T00:00:00"}
