{"id":"https://openalex.org/W3204864522","doi":null,"title":"RELIABLE POWER ELECTRONICS SYSTEM FOR RENEWABLE ENERGY SOURCES: INVESTIGATION","display_name":"RELIABLE POWER ELECTRONICS SYSTEM FOR RENEWABLE ENERGY SOURCES: INVESTIGATION","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W3204864522","mag":"3204864522"},"language":"en","primary_location":{"id":"mag:3204864522","doi":null,"is_oa":true,"landing_page_url":"http://jee.ro/index.php/jee/article/download/WJ1551088413W5c73bb1d47ac1/2315","pdf_url":null,"source":{"id":"https://openalex.org/S4210190933","display_name":"Journal of Electrical Engineering","issn_l":"1335-3632","issn":["1335-3632","1339-309X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4310313990","host_organization_name":"De Gruyter","host_organization_lineage":["https://openalex.org/P4310313990"],"host_organization_lineage_names":["De Gruyter"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Journal of Electrical Engineering-elektrotechnicky Casopis","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"http://jee.ro/index.php/jee/article/download/WJ1551088413W5c73bb1d47ac1/2315","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101678254","display_name":"M. Sujatha","orcid":"https://orcid.org/0000-0001-7006-9546","observed_orcids":["https://orcid.org/0000-0001-7006-9546"]},"institutions":[{"id":"https://openalex.org/I43663321","display_name":"Hindustan Institute of Technology and Science","ror":"https://ror.org/037tgdn13","country_code":"IN","type":"education","lineage":["https://openalex.org/I43663321"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"M.S. Sujatha","raw_affiliation_strings":["Hindustan Institute of Technology & Science"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hindustan Institute of Technology & Science","institution_ids":["https://openalex.org/I43663321"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5101678254"],"corresponding_institution_ids":["https://openalex.org/I43663321"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"20","issue":"1","first_page":"9","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.5503000020980835,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.5503000020980835,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.2142000049352646,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.1371999979019165,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-electronics-reliability","display_name":"power electronics reliability","score":0.8690000176429749},{"id":"https://openalex.org/keywords/dc-dc-converter","display_name":"DC-DC converter","score":0.953000009059906},{"id":"https://openalex.org/keywords/reliability-block-diagram","display_name":"reliability block diagram","score":0.8659999966621399},{"id":"https://openalex.org/keywords/open-circuit-fault","display_name":"open-circuit fault","score":0.8650000095367432},{"id":"https://openalex.org/keywords/temperature-variation","display_name":"temperature variation","score":0.8709999918937683},{"id":"https://openalex.org/keywords/frequency-variation","display_name":"frequency variation","score":0.9350000023841858},{"id":"https://openalex.org/keywords/reliability-prediction","display_name":"reliability prediction","score":0.5720000267028809}],"concepts":[{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7566391229629517},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6994621753692627},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.655358612537384},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6410647630691528},{"id":"https://openalex.org/C18074226","wikidata":"https://www.wikidata.org/wiki/Q7310986","display_name":"Reliability block diagram","level":3,"score":0.6232434511184692},{"id":"https://openalex.org/C149227320","wikidata":"https://www.wikidata.org/wiki/Q884718","display_name":"Block diagram","level":2,"score":0.610008180141449},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.5983637571334839},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5355356335639954},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.524696946144104},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.43893831968307495},{"id":"https://openalex.org/C138331895","wikidata":"https://www.wikidata.org/wiki/Q11650","display_name":"Electronics","level":2,"score":0.41449445486068726},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3605365753173828},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2864767909049988},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.275396466255188},{"id":"https://openalex.org/C107094494","wikidata":"https://www.wikidata.org/wiki/Q428453","display_name":"Fault tree analysis","level":2,"score":0.2304142415523529},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1117669939994812},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:3204864522","doi":null,"is_oa":true,"landing_page_url":"http://jee.ro/index.php/jee/article/download/WJ1551088413W5c73bb1d47ac1/2315","pdf_url":null,"source":{"id":"https://openalex.org/S4210190933","display_name":"Journal of Electrical Engineering","issn_l":"1335-3632","issn":["1335-3632","1339-309X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4310313990","host_organization_name":"De Gruyter","host_organization_lineage":["https://openalex.org/P4310313990"],"host_organization_lineage_names":["De Gruyter"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Journal of Electrical Engineering-elektrotechnicky Casopis","raw_type":null}],"best_oa_location":{"id":"mag:3204864522","doi":null,"is_oa":true,"landing_page_url":"http://jee.ro/index.php/jee/article/download/WJ1551088413W5c73bb1d47ac1/2315","pdf_url":null,"source":{"id":"https://openalex.org/S4210190933","display_name":"Journal of Electrical Engineering","issn_l":"1335-3632","issn":["1335-3632","1339-309X"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4310313990","host_organization_name":"De Gruyter","host_organization_lineage":["https://openalex.org/P4310313990"],"host_organization_lineage_names":["De Gruyter"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Journal of Electrical Engineering-elektrotechnicky Casopis","raw_type":null},"sustainable_development_goals":[{"score":0.9090999960899353,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4313191170","https://openalex.org/W4293254672","https://openalex.org/W2132679060","https://openalex.org/W2544587408","https://openalex.org/W2971251664","https://openalex.org/W4312401571","https://openalex.org/W2152044510","https://openalex.org/W4392108691","https://openalex.org/W4214615102","https://openalex.org/W2765240847"],"abstract_inverted_index":{"Power":[0],"devices":[1],"reliability":[2,25,46,55],"analysis":[3,65],"and":[4,59,77],"prediction":[5],"plays":[6],"an":[7],"important":[8],"role":[9],"in":[10,34,37,42],"determining":[11],"the":[12,24,54],"overall":[13],"functionality":[14],"of":[15,26,39,56,66],"renewable":[16],"energy":[17],"power":[18],"conversion":[19],"system.":[20],"In":[21],"this":[22],"paper,":[23],"various":[27],"DC-DC":[28,67],"converters":[29],"is":[30,50,69],"analysed":[31],"for":[32],"variation":[33,36,41],"frequency,":[35],"quality":[38],"components,":[40],"temperature":[43],"etc.,":[44],"Also,":[45],"block":[47],"diagram":[48],"approach":[49],"used":[51],"to":[52],"determine":[53],"system":[57],"with":[58,87],"without":[60],"open":[61],"circuit":[62],"faults.":[63],"Comparative":[64],"converter":[68],"done":[70],"by":[71],"using":[72],"Symbolic":[73],"Hierarchical":[74],"Automated":[75],"Reliability":[76],"Performance":[78],"Evaluator":[79],"tool.":[80],"The":[81],"calculated":[82],"theoretical":[83],"values":[84],"are":[85],"validated":[86],"simulation":[88],"results.":[89]},"counts_by_year":[],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2021-10-11T00:00:00"}
