{"id":"https://openalex.org/W3202255867","doi":"https://doi.org/10.1016/j.measen.2021.100233","title":"Research on the counter-force calibration method of tablet hardness tester","display_name":"Research on the counter-force calibration method of tablet hardness tester","publication_year":2021,"publication_date":"2021-09-22","ids":{"openalex":"https://openalex.org/W3202255867","doi":"https://doi.org/10.1016/j.measen.2021.100233","mag":"3202255867"},"language":"en","primary_location":{"id":"doi:10.1016/j.measen.2021.100233","doi":"https://doi.org/10.1016/j.measen.2021.100233","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.measen.2021.100233","pdf_url":null,"source":{"id":"https://openalex.org/S4210238442","display_name":"Measurement Sensors","issn_l":"2665-9174","issn":["2665-9174"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","poland-20"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Measurement: Sensors","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1016/j.measen.2021.100233","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100344931","display_name":"Zhenyu Wang","orcid":"https://orcid.org/0000-0001-7645-5667","observed_orcids":["https://orcid.org/0000-0001-7645-5667"]},"institutions":[{"id":"https://openalex.org/I4210125933","display_name":"Zhejiang Institute of Metrology","ror":"https://ror.org/02bt6bb31","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210125933"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zhenyu Wang","raw_affiliation_strings":["Henan Institute of Metrology, Zhengzhou, China","Corresponding author.; Henan Institute of Metrology, Zhengzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Henan Institute of Metrology, Zhengzhou, China","institution_ids":["https://openalex.org/I4210125933"]},{"raw_affiliation_string":"Corresponding author.; Henan Institute of Metrology, Zhengzhou, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047512154","display_name":"Xiang Ren","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210125933","display_name":"Zhejiang Institute of Metrology","ror":"https://ror.org/02bt6bb31","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210125933"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiang Ren","raw_affiliation_strings":["Henan Institute of Metrology, Zhengzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Henan Institute of Metrology, Zhengzhou, China","institution_ids":["https://openalex.org/I4210125933"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Haiying Feng","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210125933","display_name":"Zhejiang Institute of Metrology","ror":"https://ror.org/02bt6bb31","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210125933"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haiying Feng","raw_affiliation_strings":["Henan Institute of Metrology, Zhengzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Henan Institute of Metrology, Zhengzhou, China","institution_ids":["https://openalex.org/I4210125933"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5052767994","display_name":"Dejun Luo","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Dejun Luo","raw_affiliation_strings":["Shenzhen Junde Technology Co., Ltd, Shenzhen, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shenzhen Junde Technology Co., Ltd, Shenzhen, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5052767994","https://openalex.org/A5100344931"],"corresponding_institution_ids":["https://openalex.org/I4210125933"],"apc_list":{"value":1800,"currency":"USD","value_usd":1800},"apc_paid":{"value":1800,"currency":"USD","value_usd":1800},"fwci":1.2062,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.79716024,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":"18","issue":null,"first_page":"100233","last_page":"100233"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9824000000953674,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9824000000953674,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11583","display_name":"Advanced Measurement and Metrology Techniques","score":0.011900000274181366,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/force-sensor-calibration","display_name":"force sensor calibration","score":0.878000020980835},{"id":"https://openalex.org/keywords/traceability","display_name":"traceability","score":0.6100000143051147}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6194112300872803},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.345791220664978},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33911916613578796},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.2901410460472107},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.19579479098320007}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1016/j.measen.2021.100233","doi":"https://doi.org/10.1016/j.measen.2021.100233","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.measen.2021.100233","pdf_url":null,"source":{"id":"https://openalex.org/S4210238442","display_name":"Measurement Sensors","issn_l":"2665-9174","issn":["2665-9174"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","poland-20"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Measurement: Sensors","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:3e17298bff014b41857b153b4321f847","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/3e17298bff014b41857b153b4321f847","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Measurement: Sensors, Vol 18, Iss , Pp 100233- (2021)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1016/j.measen.2021.100233","doi":"https://doi.org/10.1016/j.measen.2021.100233","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.measen.2021.100233","pdf_url":null,"source":{"id":"https://openalex.org/S4210238442","display_name":"Measurement Sensors","issn_l":"2665-9174","issn":["2665-9174"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","poland-20"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Measurement: Sensors","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W2016031616","https://openalex.org/W2883871681","https://openalex.org/W4285719527"],"related_works":["https://openalex.org/W2122856337","https://openalex.org/W2058950757","https://openalex.org/W1975523725","https://openalex.org/W157875722","https://openalex.org/W4401465271","https://openalex.org/W2125646725","https://openalex.org/W2081964887","https://openalex.org/W2472283720","https://openalex.org/W2409862453","https://openalex.org/W2093494829"],"abstract_inverted_index":{"The":[0,84],"tablet":[1,67],"hardness":[2,12,24,63,68,108],"tester":[3,25,109],"is":[4,26,37,110],"mainly":[5],"a":[6,49,55,72],"measuring":[7,81],"instrument":[8],"for":[9],"testing":[10],"the":[11,16,19,23,29,62,66,78,89,94,99,103,107,116],"and":[13,70,112,114],"diameter":[14],"of":[15,22,65,74,80,92,106,118],"tablet.":[17],"Because":[18],"force":[20,100],"sensor":[21],"built":[27],"in":[28,102],"compacting":[30],"medicine":[31],"box":[32],"with":[33,42,54,77,82,98],"small":[34],"space,":[35],"it":[36],"not":[38],"easy":[39],"to":[40,47,59],"calibrate":[41],"weights.":[43,83],"This":[44],"paper":[45],"proposes":[46],"use":[48],"special":[50],"static":[51],"standard":[52,95],"dynamometer":[53,96],"counterforce":[56],"loading":[57],"mechanism":[58],"directly":[60,97],"measure":[61],"value":[64],"tester,":[69],"conduct":[71],"lot":[73],"comparison":[75],"experiments":[76],"method":[79,91],"experimental":[85],"results":[86],"show":[87],"that":[88],"calibration":[90],"superimposing":[93],"surface":[101],"working":[104],"area":[105],"simple":[111],"feasible,":[113],"meets":[115],"requirement":[117],"traceability.":[119]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2}],"updated_date":"2026-09-27T08:07:27.782135","created_date":"2021-10-11T00:00:00"}
