{"id":"https://openalex.org/W3138917164","doi":"https://doi.org/10.3390/en14061653","title":"Fault Simulations in a Multiterminal High Voltage DC Network with Modular Multilevel Converters Using Full-Bridge Submodules","display_name":"Fault Simulations in a Multiterminal High Voltage DC Network with Modular Multilevel Converters Using Full-Bridge Submodules","alternate_titles":[],"publication_year":2021,"publication_date":"2021-03-16","ids":{"openalex":"https://openalex.org/W3138917164","doi":"https://doi.org/10.3390/en14061653","mag":"3138917164"},"language":"en","primary_location":{"id":"doi:10.3390/en14061653","doi":"https://doi.org/10.3390/en14061653","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en14061653","pdf_url":"https://www.mdpi.com/1996-1073/14/6/1653/pdf?version=1615965651","source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W3138917164"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1996-1073/14/6/1653/pdf?version=1615965651","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102931864","display_name":"C\u0103t\u0103lin Damian","orcid":"https://orcid.org/0000-0002-4435-5642","observed_orcids":["https://orcid.org/0000-0002-4435-5642"]},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":true,"raw_author_name":"Ioan-C\u0103t\u0103lin Damian","raw_affiliation_strings":["University Politehnica of Bucharest, Iuliu Maniu 313, 060042 Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University Politehnica of Bucharest, Iuliu Maniu 313, 060042 Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000047384","display_name":"Mircea Eremia","orcid":"https://orcid.org/0000-0002-7872-2973","observed_orcids":["https://orcid.org/0000-0002-7872-2973"]},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Mircea Eremia","raw_affiliation_strings":["University Politehnica of Bucharest, Iuliu Maniu 313, 060042 Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University Politehnica of Bucharest, Iuliu Maniu 313, 060042 Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040388133","display_name":"Lucian Toma","orcid":"https://orcid.org/0000-0002-1281-2650","observed_orcids":["https://orcid.org/0000-0002-1281-2650"]},"institutions":[{"id":"https://openalex.org/I61641377","display_name":"Universitatea Na\u021bional\u0103 de \u0218tiin\u021b\u0103 \u0219i Tehnologie Politehnica Bucure\u0219ti","ror":"https://ror.org/0558j5q12","country_code":"RO","type":"education","lineage":["https://openalex.org/I61641377"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Lucian Toma","raw_affiliation_strings":["University Politehnica of Bucharest, Iuliu Maniu 313, 060042 Bucharest, Romania"],"raw_orcid":"https://orcid.org/0000-0002-1281-2650","affiliations":[{"raw_affiliation_string":"University Politehnica of Bucharest, Iuliu Maniu 313, 060042 Bucharest, Romania","institution_ids":["https://openalex.org/I61641377"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5102931864"],"corresponding_institution_ids":["https://openalex.org/I61641377"],"apc_list":{"value":2000,"currency":"CHF","value_usd":2160},"apc_paid":{"value":2000,"currency":"CHF","value_usd":2160},"fwci":0.1461,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.32945348,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":"14","issue":"6","first_page":"1653","last_page":"1653"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/multiterminal-hvdc","display_name":"multi-terminal HVDC","score":0.9769999980926514},{"id":"https://openalex.org/keywords/modular-multilevel-converter","display_name":"modular multilevel converter","score":0.8989999890327454},{"id":"https://openalex.org/keywords/full-bridge-submodules","display_name":"full-bridge submodules","score":0.9890000224113464},{"id":"https://openalex.org/keywords/fault-simulation","display_name":"fault simulation","score":0.8830000162124634},{"id":"https://openalex.org/keywords/fault-response","display_name":"fault response","score":0.5830000042915344},{"id":"https://openalex.org/keywords/overhead-power-lines","display_name":"overhead power lines","score":0.5329999923706055},{"id":"https://openalex.org/keywords/converter-controller-design","display_name":"converter control design","score":0.5809999704360962},{"id":"https://openalex.org/keywords/renewable-energy-integration","display_name":"renewable energy integration","score":0.8140000104904175}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.8473287224769592},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.8053534030914307},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.6966738104820251},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.6600474119186401},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5492980480194092},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5484085083007812},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.49901294708251953},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.472063809633255},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.4585520923137665},{"id":"https://openalex.org/C100776233","wikidata":"https://www.wikidata.org/wiki/Q2532492","display_name":"Bridge (graph theory)","level":2,"score":0.45537102222442627},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.4388885498046875},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.4206191301345825},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3865194320678711},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.32109546661376953},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.07579711079597473},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.3390/en14061653","doi":"https://doi.org/10.3390/en14061653","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en14061653","pdf_url":"https://www.mdpi.com/1996-1073/14/6/1653/pdf?version=1615965651","source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},{"id":"pmh:oai:RePEc:gam:jeners:v:14:y:2021:i:6:p:1653-:d:517993","doi":null,"is_oa":false,"landing_page_url":"https://www.mdpi.com/1996-1073/14/6/1653/","pdf_url":null,"source":{"id":"https://openalex.org/S4306401271","display_name":"RePEc: Research Papers in Economics","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I77793887","host_organization_name":"Federal Reserve Bank of St. Louis","host_organization_lineage":["https://openalex.org/I77793887"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},{"id":"pmh:oai:doaj.org/article:340970f93ceb430aa45463b8aaa9d548","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/340970f93ceb430aa45463b8aaa9d548","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Energies, Vol 14, Iss 6, p 1653 (2021)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.3390/en14061653","doi":"https://doi.org/10.3390/en14061653","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en14061653","pdf_url":"https://www.mdpi.com/1996-1073/14/6/1653/pdf?version=1615965651","source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.8970999717712402},{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.75}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3138917164.pdf","grobid_xml":"https://content.openalex.org/works/W3138917164.grobid-xml"},"referenced_works_count":11,"referenced_works":["https://openalex.org/W326226202","https://openalex.org/W1971571447","https://openalex.org/W2265248459","https://openalex.org/W2271607980","https://openalex.org/W2315794261","https://openalex.org/W2529426376","https://openalex.org/W2774186221","https://openalex.org/W2807448795","https://openalex.org/W3091268622","https://openalex.org/W3121002753","https://openalex.org/W7019821615"],"related_works":["https://openalex.org/W2398971549","https://openalex.org/W2276384193","https://openalex.org/W1632172561","https://openalex.org/W2889247652","https://openalex.org/W2960715973","https://openalex.org/W3160660861","https://openalex.org/W2903103534","https://openalex.org/W2905047793","https://openalex.org/W2026217566","https://openalex.org/W2588641434"],"abstract_inverted_index":{"The":[0],"concept":[1],"of":[2,15,41],"high-voltage":[3],"DC":[4,94],"transmission":[5],"using":[6],"a":[7,12,88,112],"multiterminal":[8,93],"configuration":[9,89],"is":[10,31,103],"presently":[11],"central":[13],"topic":[14],"research":[16],"and":[17,54,59,115],"investment":[18],"due":[19],"to":[20,33,38,80,91,105],"rekindled":[21],"interest":[22],"in":[23,65,78,84],"renewable":[24],"energy":[25],"resource":[26],"integration.":[27],"Moreover,":[28],"great":[29],"attention":[30],"given":[32,104],"fault":[34,106],"analysis,":[35],"which":[36,66],"leads":[37],"the":[39,82,92,121],"necessity":[40],"developing":[42],"proper":[43],"tools":[44],"that":[45,86,109,116],"enable":[46],"proficient":[47],"dynamic":[48],"simulations.":[49],"This":[50],"paper":[51,72],"leverages":[52],"models":[53],"control":[55],"system":[56],"design":[57],"techniques":[58],"demonstrates":[60],"their":[61],"appropriateness":[62],"for":[63],"scenarios":[64],"faults":[67],"are":[68],"applied.":[69],"Furthermore,":[70],"this":[71],"relies":[73],"on":[74],"full-bridge":[75,113],"submodule":[76],"topologies":[77],"order":[79],"underline":[81],"increase":[83],"resilience":[85],"such":[87],"brings":[90],"network,":[95],"after":[96],"an":[97],"unexpected":[98],"disturbance.":[99],"Therefore,":[100],"strong":[101],"focus":[102],"response,":[107],"considering":[108],"converters":[110],"use":[111],"topology":[114],"overhead":[117],"power":[118],"lines":[119],"connect":[120],"terminals.":[122]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W3138917164","counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2021-03-29T00:00:00"}