{"id":"https://openalex.org/W3134020199","doi":"https://doi.org/10.1109/sges51519.2020.00111","title":"Comparison of Different Control Methods for Maximum Power Point Tracking of Solar and Wind Energy","display_name":"Comparison of Different Control Methods for Maximum Power Point Tracking of Solar and Wind Energy","alternate_titles":[],"publication_year":2020,"publication_date":"2020-11-01","ids":{"openalex":"https://openalex.org/W3134020199","doi":"https://doi.org/10.1109/sges51519.2020.00111","mag":"3134020199"},"language":"en","primary_location":{"id":"doi:10.1109/sges51519.2020.00111","doi":"https://doi.org/10.1109/sges51519.2020.00111","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sges51519.2020.00111","pdf_url":null,"source":{"id":"https://openalex.org/S4306498724","display_name":"International Conference on Smart Grids and Energy Systems (SGES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 International Conference on Smart Grids and Energy Systems (SGES)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W3134020199"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://figshare.com/articles/conference_contribution/Comparison_of_Different_Control_Methods_for_Maximum_Power_Point_Tracking_of_Solar_and_Wind_Energy/24425236","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100341537","display_name":"Lu Jiang","orcid":"https://orcid.org/0000-0001-7283-1303","observed_orcids":["https://orcid.org/0000-0001-7283-1303"]},"institutions":[{"id":"https://openalex.org/I31746571","display_name":"UNSW Sydney","ror":"https://ror.org/03r8z3t63","country_code":"AU","type":"education","lineage":["https://openalex.org/I31746571"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Lu Jiang","raw_affiliation_strings":["School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, Australia","institution_ids":["https://openalex.org/I31746571"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101453206","display_name":"Daming Zhang","orcid":"https://orcid.org/0000-0002-7892-6976","observed_orcids":["https://orcid.org/0000-0002-7892-6976"]},"institutions":[{"id":"https://openalex.org/I31746571","display_name":"UNSW Sydney","ror":"https://ror.org/03r8z3t63","country_code":"AU","type":"education","lineage":["https://openalex.org/I31746571"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Daming Zhang","raw_affiliation_strings":["School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, Australia","institution_ids":["https://openalex.org/I31746571"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I31746571"],"apc_list":null,"apc_paid":null,"fwci":1.5641,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.78121336,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":92},"biblio":{"volume":null,"issue":null,"first_page":"596","last_page":"599"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9648000001907349,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9648000001907349,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.01810000091791153,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.007400000002235174,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"maximum power point tracking","score":1.0},{"id":"https://openalex.org/keywords/dc-dc-converter-control","display_name":"DC-DC converter control","score":0.9210000038146973},{"id":"https://openalex.org/keywords/double-closed-loop-control","display_name":"double closed-loop control","score":0.9240000247955322},{"id":"https://openalex.org/keywords/voltage-outer-loop","display_name":"voltage outer loop","score":0.6439999938011169},{"id":"https://openalex.org/keywords/inner-current-loop","display_name":"current inner loop","score":0.9629999995231628},{"id":"https://openalex.org/keywords/photovoltaic-modules","display_name":"photovoltaic modules","score":0.7149999737739563},{"id":"https://openalex.org/keywords/wind-turbines","display_name":"wind turbines","score":0.9589999914169312},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"permanent magnet synchronous generator","score":0.9629999995231628},{"id":"https://openalex.org/keywords/ac-dc-rectifier","display_name":"AC-DC rectifier","score":0.9409999847412109}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6824813485145569},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.6300863027572632},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.6299309134483337},{"id":"https://openalex.org/C116615679","wikidata":"https://www.wikidata.org/wiki/Q6795908","display_name":"Maximum power principle","level":3,"score":0.6205048561096191},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.6064208149909973},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.577301025390625},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5009009838104248},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.4486270248889923},{"id":"https://openalex.org/C161067210","wikidata":"https://www.wikidata.org/wiki/Q1464943","display_name":"Wind speed","level":2,"score":0.4432367980480194},{"id":"https://openalex.org/C541104983","wikidata":"https://www.wikidata.org/wiki/Q40015","display_name":"Solar energy","level":2,"score":0.4377455711364746},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.4180557131767273},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4050237536430359},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.37494155764579773},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37451833486557007},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1856304109096527},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.15333721041679382},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.09382680058479309},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.07880902290344238},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/sges51519.2020.00111","doi":"https://doi.org/10.1109/sges51519.2020.00111","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sges51519.2020.00111","pdf_url":null,"source":{"id":"https://openalex.org/S4306498724","display_name":"International Conference on Smart Grids and Energy Systems (SGES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 International Conference on Smart Grids and Energy Systems (SGES)","raw_type":"proceedings-article"},{"id":"pmh:oai:figshare.com:article/24425236","doi":null,"is_oa":true,"landing_page_url":"https://figshare.com/articles/conference_contribution/Comparison_of_Different_Control_Methods_for_Maximum_Power_Point_Tracking_of_Solar_and_Wind_Energy/24425236","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference contribution"}],"best_oa_location":{"id":"pmh:oai:figshare.com:article/24425236","doi":null,"is_oa":true,"landing_page_url":"https://figshare.com/articles/conference_contribution/Comparison_of_Different_Control_Methods_for_Maximum_Power_Point_Tracking_of_Solar_and_Wind_Energy/24425236","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference contribution"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":1.0}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1566254928","https://openalex.org/W1991923883","https://openalex.org/W2040578945","https://openalex.org/W2105630026","https://openalex.org/W2144576963","https://openalex.org/W2171801681","https://openalex.org/W2323857973","https://openalex.org/W2620592416"],"related_works":["https://openalex.org/W2140783248","https://openalex.org/W2626743540","https://openalex.org/W1566254928","https://openalex.org/W1988555984","https://openalex.org/W4405936922","https://openalex.org/W3150960425","https://openalex.org/W2318391857","https://openalex.org/W3083497609","https://openalex.org/W2171074346","https://openalex.org/W2098487547"],"abstract_inverted_index":{"In":[0,101],"this":[1,104],"paper,":[2],"several":[3],"DC-DC":[4],"converter":[5],"control":[6],"strategies":[7],"have":[8],"been":[9],"implemented":[10],"in":[11,32,37,45,50,75],"distributed":[12],"renewable":[13],"energy":[14,21,124],"harnessing":[15],"system":[16],"for":[17,61,78,119],"coping":[18],"with":[19,30,96],"the":[20,41,87,102,113],"shortage":[22],"and":[23,35,40,48,55,64,71,93,122],"environmental":[24],"crisis.":[25],"Double-loop":[26],"controls,":[27],"one":[28],"being":[29,43],"voltage":[31,49],"outer":[33,46],"loop":[34,39,47,52],"current":[36,44],"inner":[38,51],"other":[42],"are":[53,59,73,82],"presented":[54],"compared.":[56],"Terminal":[57],"properties":[58],"investigated":[60],"solar":[62,91,121],"panel":[63,92],"wind":[65,94,123],"turbine+PMSG":[66],"machine+AC/DC":[67],"rectifier.":[68],"Reference":[69],"voltages":[70],"currents":[72],"constructed":[74],"look-up":[76,99],"tables":[77],"control.":[79],"Both":[80],"methods":[81,110],"adopted":[83],"to":[84,98],"maximally":[85],"track":[86],"power":[88,117],"output":[89,118],"from":[90],"turbine":[95],"reference":[97],"tables.":[100],"end,":[103],"paper":[105],"concludes":[106],"that":[107],"both":[108,120],"two":[109],"can":[111],"achieve":[112],"same":[114],"successful":[115],"maximum":[116],"harnessing.":[125]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W3134020199","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2021-03-15T00:00:00"}
