{"id":"https://openalex.org/W3132772018","doi":"https://doi.org/10.1109/ei250167.2020.9346831","title":"Automatic Adjustment Method of Power Flow Calculation Convergence for Large-scale Power Grid Based on Knowledge Experience and Deep Reinforcement Learning","display_name":"Automatic Adjustment Method of Power Flow Calculation Convergence for Large-scale Power Grid Based on Knowledge Experience and Deep Reinforcement Learning","publication_year":2020,"publication_date":"2020-10-30","ids":{"openalex":"https://openalex.org/W3132772018","doi":"https://doi.org/10.1109/ei250167.2020.9346831","mag":"3132772018"},"language":"en","primary_location":{"id":"doi:10.1109/ei250167.2020.9346831","doi":"https://doi.org/10.1109/ei250167.2020.9346831","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ei250167.2020.9346831","pdf_url":null,"source":{"id":"https://openalex.org/S4363607716","display_name":"IEEE Conference on Energy Internet and Energy System Integration (EI2)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101634922","display_name":"Tianjing Wang","orcid":"https://orcid.org/0000-0003-1019-0197","observed_orcids":["https://orcid.org/0000-0003-1019-0197","https://orcid.org/0009-0003-6068-7596"]},"institutions":[{"id":"https://openalex.org/I4392738113","display_name":"China Electric Power Research Institute","ror":"https://ror.org/05ehpzy81","country_code":"CN","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4392738113"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tianjing Wang","raw_affiliation_strings":["Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China","institution_ids":["https://openalex.org/I4392738113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100643162","display_name":"Yong Tang","orcid":"https://orcid.org/0000-0002-3490-6543","observed_orcids":["https://orcid.org/0000-0002-3490-6543"]},"institutions":[{"id":"https://openalex.org/I4392738113","display_name":"China Electric Power Research Institute","ror":"https://ror.org/05ehpzy81","country_code":"CN","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4392738113"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yong Tang","raw_affiliation_strings":["Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China","institution_ids":["https://openalex.org/I4392738113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101054831","display_name":"Yanhao Huang","orcid":"https://orcid.org/0009-0008-8627-7663","observed_orcids":["https://orcid.org/0009-0008-8627-7663"]},"institutions":[{"id":"https://openalex.org/I4392738113","display_name":"China Electric Power Research Institute","ror":"https://ror.org/05ehpzy81","country_code":"CN","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4392738113"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yanhao Huang","raw_affiliation_strings":["Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China","institution_ids":["https://openalex.org/I4392738113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102776678","display_name":"Xinglei Chen","orcid":"https://orcid.org/0009-0003-3586-7798","observed_orcids":["https://orcid.org/0009-0003-3586-7798"]},"institutions":[{"id":"https://openalex.org/I4392738113","display_name":"China Electric Power Research Institute","ror":"https://ror.org/05ehpzy81","country_code":"CN","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4392738113"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xinglei Chen","raw_affiliation_strings":["Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China","institution_ids":["https://openalex.org/I4392738113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065157136","display_name":"Songtao Zhang","orcid":"https://orcid.org/0000-0002-2463-4222","observed_orcids":["https://orcid.org/0000-0002-2463-4222"]},"institutions":[{"id":"https://openalex.org/I4392738113","display_name":"China Electric Power Research Institute","ror":"https://ror.org/05ehpzy81","country_code":"CN","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4392738113"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Songtao Zhang","raw_affiliation_strings":["Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute, Beijing, China","institution_ids":["https://openalex.org/I4392738113"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079802123","display_name":"Hekai Huang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hekai Huang","raw_affiliation_strings":["Harbin Institute of Technology,Faculty of Computing,Harbin,China","Faculty of Computing, Harbin Institute of Technology, Harbin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Harbin Institute of Technology,Faculty of Computing,Harbin,China","institution_ids":["https://openalex.org/I204983213"]},{"raw_affiliation_string":"Faculty of Computing, Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":6.2632,"has_fulltext":false,"cited_by_count":33,"citation_normalized_percentile":{"value":0.98053062,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"694","last_page":"699"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.6215999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.6215999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.21230000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.09910000115633011,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-flow-convergence","display_name":"power flow convergence","score":0.8489999771118164},{"id":"https://openalex.org/keywords/deep-reinforcement-learning","display_name":"deep reinforcement learning","score":0.8730000257492065},{"id":"https://openalex.org/keywords/large-scale-power-grids","display_name":"large-scale power grids","score":0.9100000262260437},{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":0.7319999933242798},{"id":"https://openalex.org/keywords/dijkstra-s-algorithm","display_name":"Dijkstra's algorithm","score":0.8659999966621399},{"id":"https://openalex.org/keywords/active-power-balancing","display_name":"active power balancing","score":0.7490000128746033},{"id":"https://openalex.org/keywords/reward-function-design","display_name":"reward function design","score":0.4020000100135803},{"id":"https://openalex.org/keywords/northeast-china-power-grid","display_name":"Northeast China power grid","score":0.6159999966621399}],"concepts":[{"id":"https://openalex.org/C97541855","wikidata":"https://www.wikidata.org/wiki/Q830687","display_name":"Reinforcement learning","level":2,"score":0.854570746421814},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6901236176490784},{"id":"https://openalex.org/C2777303404","wikidata":"https://www.wikidata.org/wiki/Q759757","display_name":"Convergence (economics)","level":2,"score":0.6026691794395447},{"id":"https://openalex.org/C173870130","wikidata":"https://www.wikidata.org/wiki/Q8548","display_name":"Dijkstra's algorithm","level":4,"score":0.5872941613197327},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5148116946220398},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4616476595401764},{"id":"https://openalex.org/C181361822","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power-flow study","level":4,"score":0.4468466341495514},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.43526381254196167},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.4347479045391083},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4168770909309387},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3273561894893646},{"id":"https://openalex.org/C22590252","wikidata":"https://www.wikidata.org/wiki/Q1058754","display_name":"Shortest path problem","level":3,"score":0.278681218624115},{"id":"https://openalex.org/C80444323","wikidata":"https://www.wikidata.org/wiki/Q2878974","display_name":"Theoretical computer science","level":1,"score":0.12163081765174866},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.090177983045578},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C50522688","wikidata":"https://www.wikidata.org/wiki/Q189833","display_name":"Economic growth","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C132525143","wikidata":"https://www.wikidata.org/wiki/Q141488","display_name":"Graph","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ei250167.2020.9346831","doi":"https://doi.org/10.1109/ei250167.2020.9346831","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ei250167.2020.9346831","pdf_url":null,"source":{"id":"https://openalex.org/S4363607716","display_name":"IEEE Conference on Energy Internet and Energy System Integration (EI2)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.8970999717712402,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W32403112","https://openalex.org/W1504194272","https://openalex.org/W1921523184","https://openalex.org/W2037027777","https://openalex.org/W2039911933","https://openalex.org/W2141548708","https://openalex.org/W2142775557","https://openalex.org/W2170632053","https://openalex.org/W2355713298","https://openalex.org/W2357713685","https://openalex.org/W2360874609","https://openalex.org/W2363655158","https://openalex.org/W2368240603","https://openalex.org/W2369044373","https://openalex.org/W2373975357","https://openalex.org/W2385167285","https://openalex.org/W2746553466","https://openalex.org/W2914656440","https://openalex.org/W2919115771"],"related_works":["https://openalex.org/W4385414889","https://openalex.org/W7162643192","https://openalex.org/W3173124910","https://openalex.org/W3109689360","https://openalex.org/W3112537643","https://openalex.org/W3089348557","https://openalex.org/W4405906781","https://openalex.org/W3205329572","https://openalex.org/W4280580458","https://openalex.org/W4391877810"],"abstract_inverted_index":{"In":[0],"order":[1],"to":[2,139,173],"solve":[3],"the":[4,43,52,79,94,100,119,124,145,158,167,175,178],"problem":[5],"of":[6,16,28,46,57,73,81,102,154,177],"manpower":[7],"and":[8,36,51,55,70,89,112,123,142,166],"time":[9],"cost":[10],"consumption":[11],"caused":[12],"by":[13,86,152],"strict":[14],"non-convergence":[15],"power":[17,21,29,47,111,125,150,169],"flow":[18,30,48,126],"in":[19],"large-scale":[20],"grid":[22,170],"calculation,":[23],"an":[24],"automatic":[25],"adjustment":[26,50,104,127],"method":[27],"convergence":[31,49],"based":[32],"on":[33],"knowledge":[34,44,88],"experience":[35,45,90],"deep":[37,58,82],"reinforcement":[38,59,74,92],"learning":[39,60],"is":[40,97,105,108,129,137],"proposed.":[41],"Firstly,":[42],"basic":[53],"concepts":[54],"principles":[56],"are":[61,171],"introduced.":[62],"Then":[63],"we":[64],"design":[65],"state":[66],"space,":[67],"action":[68],"space":[69,96],"multiple":[71],"rewards":[72],"learning,":[75,93],"as":[76,78],"well":[77],"framework":[80],"neural":[83],"network.":[84],"Next,":[85],"adding":[87],"into":[91],"search":[95,120],"narrowed.":[98],"And":[99],"process":[101],"human":[103],"simulated,":[106],"which":[107],"balancing":[109,114,132],"active":[110],"then":[113],"reactive":[115,133,149],"power.":[116],"So":[117],"that":[118],"has":[121],"directivity,":[122],"strategy":[128],"constructed.":[130],"When":[131],"power,":[134],"Dijkstra":[135],"algorithm":[136],"used":[138,172],"locate":[140],"capacitors":[141],"reactors":[143],"near":[144],"nodes":[146],"with":[147],"potential":[148],"deficiency":[151],"means":[153],"optimal":[155],"path.":[156],"Finally,":[157],"CEPRI(China":[159],"Electric":[160],"Power":[161],"Research":[162],"Institute)":[163],"36-node":[164],"system":[165],"northeast":[168],"verify":[174],"effectiveness":[176],"method.":[179]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":8},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2021-03-01T00:00:00"}
