{"id":"https://openalex.org/W3131742660","doi":"https://doi.org/10.1049/iet-rpg.2020.0638","title":"Response of a grid forming wind farm to system events, and the impact of external and internal damping","display_name":"Response of a grid forming wind farm to system events, and the impact of external and internal damping","publication_year":2020,"publication_date":"2020-12-01","ids":{"openalex":"https://openalex.org/W3131742660","doi":"https://doi.org/10.1049/iet-rpg.2020.0638","mag":"3131742660"},"language":"en","primary_location":{"id":"doi:10.1049/iet-rpg.2020.0638","doi":"https://doi.org/10.1049/iet-rpg.2020.0638","is_oa":false,"landing_page_url":"https://doi.org/10.1049/iet-rpg.2020.0638","pdf_url":null,"source":{"id":"https://openalex.org/S42668443","display_name":"IET Renewable Power Generation","issn_l":"1752-1416","issn":["1752-1416","1752-1424"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-2","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Renewable Power Generation","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5026720701","display_name":"Andrew Roscoe","orcid":"https://orcid.org/0000-0003-1108-4265","observed_orcids":["https://orcid.org/0000-0003-1108-4265"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Andrew Roscoe","raw_affiliation_strings":["Converter Control Group, Siemens-Gamesa, Glasgow, Scotland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Converter Control Group, Siemens-Gamesa, Glasgow, Scotland","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057197560","display_name":"Thyge Kn\u00fcppel","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Thyge Knueppel","raw_affiliation_strings":["Converter Control Group, Siemens-Gamesa, Glasgow, Scotland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Converter Control Group, Siemens-Gamesa, Glasgow, Scotland","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Ricardo Da Silva","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I10488764","display_name":"Scottish Power (United Kingdom)","ror":"https://ror.org/048hrc512","country_code":"GB","type":"company","lineage":["https://openalex.org/I10488764"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Ricardo Da Silva","raw_affiliation_strings":["Grid and Regulation Analyst, ScottishPower Renewables, Glasgow, Scotland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grid and Regulation Analyst, ScottishPower Renewables, Glasgow, Scotland","institution_ids":["https://openalex.org/I10488764"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Paul Brogan","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Paul Brogan","raw_affiliation_strings":["Converter Control Group, Siemens-Gamesa, Glasgow, Scotland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Converter Control Group, Siemens-Gamesa, Glasgow, Scotland","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048282181","display_name":"Isaac Gutierrez","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I10488764","display_name":"Scottish Power (United Kingdom)","ror":"https://ror.org/048hrc512","country_code":"GB","type":"company","lineage":["https://openalex.org/I10488764"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Isaac Gutierrez","raw_affiliation_strings":["Control and Grid Integration, ScottishPower Renewables, Glasgow, Scotland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Control and Grid Integration, ScottishPower Renewables, Glasgow, Scotland","institution_ids":["https://openalex.org/I10488764"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088422768","display_name":"Douglas Elliott","orcid":"https://orcid.org/0009-0002-6665-750X","observed_orcids":["https://orcid.org/0009-0002-6665-750X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Douglas Elliott","raw_affiliation_strings":["Converter Control Group, Siemens-Gamesa, Glasgow, Scotland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Converter Control Group, Siemens-Gamesa, Glasgow, Scotland","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004952929","display_name":"Juan Carlos Perez Campion","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210087680","display_name":"Iberdrola (Spain)","ror":"https://ror.org/0030ewy42","country_code":"ES","type":"company","lineage":["https://openalex.org/I4210087680"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Juan\u2010Carlos Perez Campion","raw_affiliation_strings":["Control and Grid Integration, Iberdrola Renovables, Madrid, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Control and Grid Integration, Iberdrola Renovables, Madrid, Spain","institution_ids":["https://openalex.org/I4210087680"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5026720701"],"corresponding_institution_ids":[],"apc_list":{"value":3500,"currency":"USD","value_usd":3500},"apc_paid":null,"fwci":1.8053,"has_fulltext":false,"cited_by_count":58,"citation_normalized_percentile":{"value":0.85086449,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":96,"max":100},"biblio":{"volume":"14","issue":"19","first_page":"3908","last_page":"3917"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.8901000022888184,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.8901000022888184,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.09610000252723694,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.006500000134110451,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/grid-forming-inverters","display_name":"grid-forming inverters","score":0.921999990940094},{"id":"https://openalex.org/keywords/wind-farms","display_name":"wind farms","score":0.902999997138977},{"id":"https://openalex.org/keywords/frequency-response","display_name":"frequency response","score":0.5759999752044678},{"id":"https://openalex.org/keywords/inertia","display_name":"inertia","score":0.3140000104904175},{"id":"https://openalex.org/keywords/internal-friction","display_name":"internal friction","score":0.6549999713897705},{"id":"https://openalex.org/keywords/external-damping","display_name":"external damping","score":0.9229999780654907},{"id":"https://openalex.org/keywords/power-converter-control","display_name":"converter control","score":0.5139999985694885},{"id":"https://openalex.org/keywords/droop-control","display_name":"droop control","score":0.7089999914169312},{"id":"https://openalex.org/keywords/power-sharing","display_name":"power sharing","score":0.6330000162124634},{"id":"https://openalex.org/keywords/frequency-disturbance","display_name":"frequency disturbance","score":0.8180000185966492},{"id":"https://openalex.org/keywords/low-inertia-power-systems","display_name":"low-inertia power systems","score":0.4659999907016754},{"id":"https://openalex.org/keywords/wind-turbines","display_name":"wind turbines","score":0.4399999976158142}],"concepts":[{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6523371934890747},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.39266589283943176},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.32310929894447327},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3158276677131653},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.19611918926239014},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.14139670133590698},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.09167438745498657},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/iet-rpg.2020.0638","doi":"https://doi.org/10.1049/iet-rpg.2020.0638","is_oa":false,"landing_page_url":"https://doi.org/10.1049/iet-rpg.2020.0638","pdf_url":null,"source":{"id":"https://openalex.org/S42668443","display_name":"IET Renewable Power Generation","issn_l":"1752-1416","issn":["1752-1416","1752-1424"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-2","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Renewable Power Generation","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.5378999710083008,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"},{"score":0.4399999976158142,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2513435681","https://openalex.org/W2524200249","https://openalex.org/W2528722222","https://openalex.org/W2999625554"],"related_works":["https://openalex.org/W7036595720","https://openalex.org/W7046158192","https://openalex.org/W4306399834","https://openalex.org/W4312884157","https://openalex.org/W4312927099","https://openalex.org/W7035592143","https://openalex.org/W6999399708","https://openalex.org/W7043972814","https://openalex.org/W3007828665","https://openalex.org/W6926132796"],"abstract_inverted_index":{"Following":[0],"from":[1],"smaller\u2010scale":[2],"investigations":[3],"of":[4,85],"grid\u2010forming":[5,47,65,157,212],"converter":[6],"control":[7],"applied":[8],"to":[9,44,55,91,101,107,121,133,147,165],"wind":[10,24,42],"turbines":[11,104,118],"in":[12,46,52,63,155,174,180,195,210],"2017\u20132018,":[13],"this":[14,36,181],"study":[15,182],"describes":[16],"a":[17,123,144,156],"much":[18],"larger":[19],"trial":[20],"involving":[21],"an":[22],"entire":[23],"farm,":[25],"owned":[26],"and":[27,49,78,98,125,168,191],"operated":[28],"by":[29,204],"ScottishPower":[30],"Renewables.":[31],"To":[32],"the":[33,38,50,53,64,134,211],"authors\u2019":[34],"knowledge,":[35],"was":[37],"first":[39],"UK":[40],"converter\u2010connected":[41],"farm":[43,61],"operate":[45],"mode,":[48],"largest":[51],"world":[54],"date.":[56],"The":[57,117,140],"23\u2010turbine,":[58],"69":[59],"MW":[60],"ran":[62],"mode":[66],"for":[67],"6":[68],"weeks,":[69],"exploring":[70],"inertia":[71,131],"contributions":[72],"between":[73],"H":[74,79],"=":[75,80],"0.2":[76],"s":[77],"8":[81],"s.":[82],"A":[83],"number":[84],"unscheduled":[86],"frequency":[87,135],"disturbances":[88],"occurred":[89],"due":[90],"interconnector,":[92],"combined":[93],"cycle":[94],"gas":[95],"turbine":[96],"(CCGT)":[97],"other":[99],"trips,":[100],"which":[102],"un\u2010curtailed":[103],"were":[105,114,119],"able":[106,120],"respond.":[108],"In":[109],"addition,":[110],"several":[111],"deliberate":[112],"tests":[113],"carried":[115],"out.":[116],"provide":[122],"stable":[124,167],"appropriate":[126],"response":[127],"at":[128],"relatively":[129],"high":[130],"levels":[132],"events":[136],"commonly":[137],"occurring":[138],"today.":[139],"captured":[141],"responses":[142],"stimulated":[143],"debate":[145],"as":[146],"whether":[148,160],"external":[149,196],"damping":[150,162,187,197],"power":[151,198],"might":[152],"be":[153,200],"required":[154],"converter,":[158],"or":[159],"internal":[161,186],"is":[163,188],"sufficient":[164],"allow":[166],"robust":[169],"power\u2010sharing":[170],"with":[171],"parallel":[172],"devices":[173],"all":[175],"grid":[176],"event":[177],"scenarios.":[178],"Analysis":[179],"suggests":[183],"that,":[184],"practically,":[185],"probably":[189],"appropriate,":[190],"that":[192],"any":[193],"deficiency":[194],"can":[199],"more":[201],"than":[202],"mitigated":[203],"reactance":[205],"and/or":[206],"droop\u2010slope":[207],"response\u2010time":[208],"management":[209],"converters.":[213]},"counts_by_year":[{"year":2026,"cited_by_count":11},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":20},{"year":2023,"cited_by_count":13},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":4}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2021-03-01T00:00:00"}