{"id":"https://openalex.org/W3127078472","doi":"https://doi.org/10.1109/tpwrd.2021.3056876","title":"Fast Fault Identification in Bipolar HVDC Grids: A Fault Parameter Estimation Approach","display_name":"Fast Fault Identification in Bipolar HVDC Grids: A Fault Parameter Estimation Approach","publication_year":2021,"publication_date":"2021-02-05","ids":{"openalex":"https://openalex.org/W3127078472","doi":"https://doi.org/10.1109/tpwrd.2021.3056876","mag":"3127078472"},"language":"en","primary_location":{"id":"doi:10.1109/tpwrd.2021.3056876","doi":"https://doi.org/10.1109/tpwrd.2021.3056876","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpwrd.2021.3056876","pdf_url":null,"source":{"id":"https://openalex.org/S203966947","display_name":"IEEE Transactions on Power Delivery","issn_l":"0885-8977","issn":["0885-8977","1937-4208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-2","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Delivery","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://hal.science/hal-03172421v1/document","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5001431250","display_name":"Paul Verrax","orcid":"https://orcid.org/0000-0001-6609-5506","observed_orcids":["https://orcid.org/0000-0001-6609-5506"]},"institutions":[{"id":"https://openalex.org/I4210162694","display_name":"Supergrid Institute","ror":"https://ror.org/05wsx4f18","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4210162694"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Paul Verrax","raw_affiliation_strings":["SuperGrid Institute, Villeurbanne, France","SuperGrid Institute SAS"],"raw_orcid":"https://orcid.org/0000-0001-6609-5506","affiliations":[{"raw_affiliation_string":"SuperGrid Institute, Villeurbanne, France","institution_ids":["https://openalex.org/I4210162694"]},{"raw_affiliation_string":"SuperGrid Institute SAS","institution_ids":["https://openalex.org/I4210162694"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018236982","display_name":"Alberto Bertinato","orcid":"https://orcid.org/0009-0004-7842-0715","observed_orcids":["https://orcid.org/0009-0004-7842-0715"]},"institutions":[{"id":"https://openalex.org/I4210162694","display_name":"Supergrid Institute","ror":"https://ror.org/05wsx4f18","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4210162694"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Alberto Bertinato","raw_affiliation_strings":["SuperGrid Institute, Villeurbanne, France","SuperGrid Institute SAS"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SuperGrid Institute, Villeurbanne, France","institution_ids":["https://openalex.org/I4210162694"]},{"raw_affiliation_string":"SuperGrid Institute SAS","institution_ids":["https://openalex.org/I4210162694"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090674929","display_name":"Michel Kieffer","orcid":"https://orcid.org/0000-0002-1049-3123","observed_orcids":["https://orcid.org/0000-0002-1049-3123"]},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I277688954","display_name":"Universit\u00e9 Paris-Saclay","ror":"https://ror.org/03xjwb503","country_code":"FR","type":"education","lineage":["https://openalex.org/I277688954"]},{"id":"https://openalex.org/I4210097418","display_name":"Laboratoire des signaux et syst\u00e8mes","ror":"https://ror.org/00skw9v43","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I277688954","https://openalex.org/I4210097418","https://openalex.org/I4210107720"]},{"id":"https://openalex.org/I4210107720","display_name":"CentraleSup\u00e9lec","ror":"https://ror.org/019tcpt25","country_code":"FR","type":"facility","lineage":["https://openalex.org/I277688954","https://openalex.org/I4210107720"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Michel Kieffer","raw_affiliation_strings":["L2S, University Paris-Sud, CNRS, CentraleSupelec, University Paris-Saclay, Gif-sur-Yvette, France","Laboratoire des signaux et syst\u00e8mes"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"L2S, University Paris-Sud, CNRS, CentraleSupelec, University Paris-Saclay, Gif-sur-Yvette, France","institution_ids":["https://openalex.org/I1294671590","https://openalex.org/I277688954","https://openalex.org/I4210097418","https://openalex.org/I4210107720"]},{"raw_affiliation_string":"Laboratoire des signaux et syst\u00e8mes","institution_ids":["https://openalex.org/I4210097418"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035092081","display_name":"Bertrand Raison","orcid":"https://orcid.org/0000-0002-1843-4021","observed_orcids":["https://orcid.org/0000-0002-1843-4021"]},"institutions":[{"id":"https://openalex.org/I106785703","display_name":"Institut polytechnique de Grenoble","ror":"https://ror.org/05sbt2524","country_code":"FR","type":"education","lineage":["https://openalex.org/I106785703","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210165697","display_name":"Laboratoire de G\u00e9nie \u00c9lectrique de Grenoble","ror":"https://ror.org/05hyx5a17","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210165697","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I899635006","display_name":"Universit\u00e9 Grenoble Alpes","ror":"https://ror.org/02rx3b187","country_code":"FR","type":"education","lineage":["https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Bertrand Raison","raw_affiliation_strings":["University Grenoble Alpes, CNRS, Grenoble INP*, G2Elab, Grenoble, France","Laboratoire de G\u00e9nie Electrique de Grenoble"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University Grenoble Alpes, CNRS, Grenoble INP*, G2Elab, Grenoble, France","institution_ids":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210165697","https://openalex.org/I899635006"]},{"raw_affiliation_string":"Laboratoire de G\u00e9nie Electrique de Grenoble","institution_ids":["https://openalex.org/I4210165697"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":8,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2045,"currency":"USD","value_usd":2045},"apc_paid":null,"fwci":1.1016,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.73956508,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":99},"biblio":{"volume":"37","issue":"1","first_page":"258","last_page":"267"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.5092999935150146,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.5092999935150146,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.48539999127388,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0017999999690800905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-identification","display_name":"fault identification","score":0.75},{"id":"https://openalex.org/keywords/fault-parameter-estimation","display_name":"fault parameter estimation","score":0.9100000262260437},{"id":"https://openalex.org/keywords/single-ended-protection","display_name":"single-ended protection","score":0.7279999852180481},{"id":"https://openalex.org/keywords/fault-distance-estimation","display_name":"fault distance estimation","score":0.8309999704360962},{"id":"https://openalex.org/keywords/confidence-regions","display_name":"confidence regions","score":0.6039999723434448},{"id":"https://openalex.org/keywords/multiconductor-transmission-lines","display_name":"multiconductor transmission lines","score":0.7160000205039978},{"id":"https://openalex.org/keywords/traveling-waves","display_name":"traveling waves","score":0.652999997138977}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7242610454559326},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.6476278305053711},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.640401303768158},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.6155785918235779},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.5844293832778931},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.5571145415306091},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5537539124488831},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5212348699569702},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5101442933082581},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.4964466691017151},{"id":"https://openalex.org/C2775861652","wikidata":"https://www.wikidata.org/wiki/Q110701","display_name":"Overhead line","level":2,"score":0.4936772286891937},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.46090754866600037},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.42502760887145996},{"id":"https://openalex.org/C117251300","wikidata":"https://www.wikidata.org/wiki/Q1849855","display_name":"Parametric statistics","level":2,"score":0.42367318272590637},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41543421149253845},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41476157307624817},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3854072093963623},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.367412805557251},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.30673694610595703},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1536785066127777},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.12278202176094055},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07343405485153198},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tpwrd.2021.3056876","doi":"https://doi.org/10.1109/tpwrd.2021.3056876","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpwrd.2021.3056876","pdf_url":null,"source":{"id":"https://openalex.org/S203966947","display_name":"IEEE Transactions on Power Delivery","issn_l":"0885-8977","issn":["0885-8977","1937-4208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-2","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Delivery","raw_type":"journal-article"},{"id":"pmh:oai:HAL:hal-03172421v1","doi":null,"is_oa":true,"landing_page_url":"https://hal.science/hal-03172421v1/document","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4405252976","host_organization_name":"Centre pour la Communication Scientifique Directe","host_organization_lineage":["https://openalex.org/I4405252976"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Power Delivery, 2022, 37 (1), pp.258-267. &#x27E8;10.1109/TPWRD.2021.3056876&#x27E9;","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:HAL:hal-03172421v1","doi":null,"is_oa":true,"landing_page_url":"https://hal.science/hal-03172421v1/document","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4405252976","host_organization_name":"Centre pour la Communication Scientifique Directe","host_organization_lineage":["https://openalex.org/I4405252976"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Power Delivery, 2022, 37 (1), pp.258-267. &#x27E8;10.1109/TPWRD.2021.3056876&#x27E9;","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"score":0.4943999946117401,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1485426748","https://openalex.org/W1535803693","https://openalex.org/W1967780318","https://openalex.org/W1969347790","https://openalex.org/W2024202482","https://openalex.org/W2034978548","https://openalex.org/W2057696289","https://openalex.org/W2068412540","https://openalex.org/W2085406746","https://openalex.org/W2086376312","https://openalex.org/W2146298079","https://openalex.org/W2158698691","https://openalex.org/W2330170611","https://openalex.org/W2545628712","https://openalex.org/W2801032130","https://openalex.org/W2891363850","https://openalex.org/W2914287856","https://openalex.org/W2929609226","https://openalex.org/W2999523976","https://openalex.org/W3023800783","https://openalex.org/W3113574004","https://openalex.org/W3114391899"],"related_works":["https://openalex.org/W3023800783","https://openalex.org/W3152663676","https://openalex.org/W3113574004","https://openalex.org/W4311595807","https://openalex.org/W3198250095","https://openalex.org/W3178920589","https://openalex.org/W2110256194","https://openalex.org/W4321194344","https://openalex.org/W4403126920","https://openalex.org/W3046916158"],"abstract_inverted_index":{"The":[0,86,128,149,163],"protection":[1],"of":[2,10,32,36,48,81,131,176,193],"meshed":[3],"HVDC":[4,195],"grids":[5],"requires":[6,60],"the":[7,13,24,33,37,49,82,97,101,104,114,121,125,132,141,169,190],"fast":[8,65],"identification":[9,74],"faults":[11],"affecting":[12],"transmission":[14,25],"lines.":[15],"Communication-based":[16],"methods":[17],"are":[18,117],"thus":[19],"not":[20],"suited":[21],"due":[22],"to":[23,138,167],"delays.":[26],"Many":[27],"approaches":[28],"involving":[29],"a":[30,71,77,110,155,173],"model":[31,80,87,122],"transient":[34,84],"behavior":[35],"faulty":[38,146,170],"line":[39,143,171],"have":[40],"recently":[41],"been":[42],"proposed.":[43],"Nevertheless,":[44],"an":[45],"accurate":[46],"description":[47],"traveling":[50],"wave":[51],"phenomenon":[52],"in":[53],"multi-conductor":[54],"lines":[55,59],"such":[56],"as":[57],"overhead":[58],"complex":[61],"computations":[62],"ill-suited":[63],"for":[64],"fault":[66,73,83,105,111,115,134,184],"identification.":[67],"This":[68,181],"paper":[69],"presents":[70],"single-ended":[72],"algorithm":[75,151],"using":[76,172],"closed-form":[78],"parametric":[79],"behavior.":[85],"combines":[88],"physical":[89],"and":[90,93,107,186],"behavioral":[91],"parts":[92],"depends":[94],"explicitly":[95],"on":[96,154],"parameters":[98,116,135],"that":[99,120],"characterize":[100],"fault,":[102],"namely":[103],"distance":[106],"impedance.":[108],"When":[109],"is":[112,136,144,152,165],"suspected,":[113],"estimated":[118,133],"so":[119],"fits":[123],"best":[124],"received":[126],"measurements.":[127],"confidence":[129],"region":[130],"used":[137],"decide":[139],"whether":[140],"protected":[142],"actually":[145],"or":[147],"not.":[148],"proposed":[150],"tested":[153],"4":[156],"station":[157],"grid":[158],"simulated":[159],"with":[160],"EMTP-RV":[161],"software.":[162],"method":[164],"able":[166],"identify":[168],"measurement":[174],"window":[175],"less":[177],"than":[178],"0.5":[179],"ms.":[180],"allows":[182],"ultra-fast":[183],"clearing":[185],"can":[187],"hence":[188],"improve":[189],"overall":[191],"reliability":[192],"future":[194],"grids.":[196]},"counts_by_year":[{"year":2026,"cited_by_count":6},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":1}],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2021-02-15T00:00:00"}