{"id":"https://openalex.org/W3126967110","doi":null,"title":"Optimization of The Superhydrophobic Insulation Longevity Covered With Water Drops Under DC Voltage","display_name":"Optimization of The Superhydrophobic Insulation Longevity Covered With Water Drops Under DC Voltage","publication_year":2020,"publication_date":"2020-09-13","ids":{"openalex":"https://openalex.org/W3126967110","mag":"3126967110"},"language":"en","primary_location":{"id":"mag:3126967110","doi":null,"is_oa":false,"landing_page_url":"http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=9275703","pdf_url":null,"source":{"id":"https://openalex.org/S7407087140","display_name":"International Symposium on Electrical Insulating Materials (ISEIM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Symposium on Electrical Insulating Materials","raw_type":null},"volume":null,"type":"conference-paper","indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028278259","display_name":"K. Hamour","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I187560010","display_name":"University of B\u00e9ja\u00efa","ror":"https://ror.org/03yb2hp88","country_code":"DZ","type":"education","lineage":["https://openalex.org/I187560010"]}],"countries":["DZ"],"is_corresponding":false,"raw_author_name":"K. Hamour","raw_affiliation_strings":["Laboratory of Electrical Engineering, University A. Mira de Bejaia,Department of Electrical Engineering,Bejaia,Algeria,06000"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Electrical Engineering, University A. Mira de Bejaia,Department of Electrical Engineering,Bejaia,Algeria,06000","institution_ids":["https://openalex.org/I187560010"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087273144","display_name":"Fatma Bouchelga","orcid":"https://orcid.org/0000-0001-8594-7719","observed_orcids":["https://orcid.org/0000-0001-8594-7719"]},"institutions":[{"id":"https://openalex.org/I187560010","display_name":"University of B\u00e9ja\u00efa","ror":"https://ror.org/03yb2hp88","country_code":"DZ","type":"education","lineage":["https://openalex.org/I187560010"]}],"countries":["DZ"],"is_corresponding":false,"raw_author_name":"Fatma Bouchelga","raw_affiliation_strings":["Laboratory of Electrical Engineering, University A. Mira de Bejaia,Department of Electrical Engineering,Bejaia,Algeria,06000"],"raw_orcid":"https://orcid.org/0000-0001-8594-7719","affiliations":[{"raw_affiliation_string":"Laboratory of Electrical Engineering, University A. Mira de Bejaia,Department of Electrical Engineering,Bejaia,Algeria,06000","institution_ids":["https://openalex.org/I187560010"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5085853160","display_name":"Rabah Boudissa","orcid":"https://orcid.org/0000-0001-5111-0670","observed_orcids":["https://orcid.org/0000-0001-5111-0670"]},"institutions":[{"id":"https://openalex.org/I187560010","display_name":"University of B\u00e9ja\u00efa","ror":"https://ror.org/03yb2hp88","country_code":"DZ","type":"education","lineage":["https://openalex.org/I187560010"]}],"countries":["DZ"],"is_corresponding":false,"raw_author_name":"Rabah Boudissa","raw_affiliation_strings":["Laboratory of Electrical Engineering, University A. Mira de Bejaia,Department of Electrical Engineering,Bejaia,Algeria,06000"],"raw_orcid":"https://orcid.org/0000-0001-5111-0670","affiliations":[{"raw_affiliation_string":"Laboratory of Electrical Engineering, University A. Mira de Bejaia,Department of Electrical Engineering,Bejaia,Algeria,06000","institution_ids":["https://openalex.org/I187560010"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007811119","display_name":"Stefan Kornhuber","orcid":"https://orcid.org/0000-0002-7799-3552","observed_orcids":["https://orcid.org/0000-0002-7799-3552"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Stefan Kornhuber","raw_affiliation_strings":["University of Applied Sciences (Germany)"],"raw_orcid":"https://orcid.org/0000-0002-7799-3552","affiliations":[{"raw_affiliation_string":"University of Applied Sciences (Germany)","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111883578","display_name":"K.-D. Haim","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"K.-D. Haim","raw_affiliation_strings":["University of Applied Sciences (Germany)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Applied Sciences (Germany)","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.8081,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.86070039,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":95},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9775000214576721,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9775000214576721,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10313","display_name":"Surface Modification and Superhydrophobicity","score":0.01889999955892563,"subfield":{"id":"https://openalex.org/subfields/2508","display_name":"Surfaces, Coatings and Films"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12696","display_name":"Icing and De-icing Technologies","score":0.0008999999845400453,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/silicone-coating","display_name":"silicone coating","score":0.75},{"id":"https://openalex.org/keywords/dc-flashover","display_name":"DC flashover","score":0.628000020980835},{"id":"https://openalex.org/keywords/partial-discharge","display_name":"partial discharge","score":0.847000002861023},{"id":"https://openalex.org/keywords/surface-contamination","display_name":"surface contamination","score":0.5559999942779541}],"concepts":[{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7951892614364624},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.711065411567688},{"id":"https://openalex.org/C200769187","wikidata":"https://www.wikidata.org/wiki/Q2360656","display_name":"Arc flash","level":3,"score":0.649385392665863},{"id":"https://openalex.org/C103208741","wikidata":"https://www.wikidata.org/wiki/Q1675349","display_name":"Service life","level":2,"score":0.5367812514305115},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5362389087677002},{"id":"https://openalex.org/C176864760","wikidata":"https://www.wikidata.org/wiki/Q217651","display_name":"Moisture","level":2,"score":0.4870505630970001},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.4800656735897064},{"id":"https://openalex.org/C6556556","wikidata":"https://www.wikidata.org/wiki/Q899239","display_name":"Contact angle","level":2,"score":0.4494490325450897},{"id":"https://openalex.org/C112439578","wikidata":"https://www.wikidata.org/wiki/Q17146559","display_name":"Superhydrophobic coating","level":3,"score":0.42956700921058655},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3249858021736145},{"id":"https://openalex.org/C212702","wikidata":"https://www.wikidata.org/wiki/Q178150","display_name":"Insulator (electricity)","level":2,"score":0.3093852996826172},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.08434084057807922},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0842844545841217},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:3126967110","doi":null,"is_oa":false,"landing_page_url":"http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=9275703","pdf_url":null,"source":{"id":"https://openalex.org/S7407087140","display_name":"International Symposium on Electrical Insulating Materials (ISEIM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Symposium on Electrical Insulating Materials","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4943999946117401,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2978414827","https://openalex.org/W3014598105","https://openalex.org/W2614460725","https://openalex.org/W2576310750","https://openalex.org/W3212460732","https://openalex.org/W4289915750","https://openalex.org/W2542205525","https://openalex.org/W2908506780","https://openalex.org/W2784170629","https://openalex.org/W4391422301"],"abstract_inverted_index":{"The":[0,81],"electrical":[1,74,132],"networks":[2],"are":[3],"confronted":[4],"with":[5],"several":[6],"problems":[7],"that":[8,17,107,115],"lead":[9],"to":[10,14,41,49,68,105],"service":[11],"disruption":[12],"due":[13],"the":[15,24,30,51,58,70,88,95,125,134],"pollution":[16],"is":[18,139,144],"deposited":[19],"in":[20,66],"layer":[21],"form":[22],"and":[23,48,141],"persistence":[25],"of":[26,32,53,72,91,108,118,121,136],"water":[27,54,92,122],"drops":[28,93,123],"by":[29],"effect":[31],"moisture":[33],"on":[34,46,124],"hydrophobic":[35],"insulators.":[36],"Our":[37],"experimental":[38,85],"work":[39],"aims":[40],"manufacture":[42],"superhydrophobic":[43,126],"insulation":[44],"based":[45],"silicone":[47],"control":[50],"evacuation":[52],"droplets":[55],"deposits":[56],"covering":[57],"surface":[59,96,138],"using":[60],"a":[61,98,116,119],"very":[62],"suitable":[63],"electrode":[64],"profile":[65],"order":[67],"prevent":[69],"development":[71],"partial":[73],"discharges":[75],"and/or":[76],"flashover":[77],"under":[78],"DC":[79],"voltage.":[80],"results":[82,113],"from":[83],"this":[84],"study":[86],"show":[87],"expulsion":[89],"mode":[90],"out":[94],"requires":[97],"test":[99],"voltage":[100],"less":[101],"than":[102],"or":[103],"equal":[104],"half":[106],"its":[109,137,142],"flashover.":[110],"Furthermore,":[111],"these":[112],"reveal":[114],"deposit":[117],"set":[120],"insulation,":[127],"whatever":[128],"their":[129,131],"volume,":[130],"conductivity,":[133],"superhydrophobicity":[135],"retained":[140],"longevity":[143],"optimized.":[145]},"counts_by_year":[{"year":2022,"cited_by_count":2}],"updated_date":"2026-11-01T11:40:01.658920","created_date":"2021-02-15T00:00:00"}
