{"id":"https://openalex.org/W3119731952","doi":"https://doi.org/10.1541/ieejpes.141.13","title":"Method of Predicting for Charge Voltage Due to Ion Flow on Insulated Wire with Grounded Core Conductor under HVDC Overhead Transmission Line","display_name":"Method of Predicting for Charge Voltage Due to Ion Flow on Insulated Wire with Grounded Core Conductor under HVDC Overhead Transmission Line","alternate_titles":[],"publication_year":2020,"publication_date":"2020-12-31","ids":{"openalex":"https://openalex.org/W3119731952","doi":"https://doi.org/10.1541/ieejpes.141.13","mag":"3119731952"},"language":"en","primary_location":{"id":"doi:10.1541/ieejpes.141.13","doi":"https://doi.org/10.1541/ieejpes.141.13","is_oa":false,"landing_page_url":"https://doi.org/10.1541/ieejpes.141.13","pdf_url":null,"source":{"id":"https://openalex.org/S53799065","display_name":"IEEJ Transactions on Power and Energy","issn_l":"0385-4213","issn":["0385-4213","1348-8147"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800591","host_organization_name":"Institute of Electrical Engineers of Japan","host_organization_lineage":["https://openalex.org/P4320800591"],"host_organization_lineage_names":["Institute of Electrical Engineers of Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEJ Transactions on Power and Energy","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W3119731952"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103075215","display_name":"Takeo Shiina","orcid":"https://orcid.org/0000-0003-4921-7051","observed_orcids":["https://orcid.org/0000-0003-4921-7051"]},"institutions":[{"id":"https://openalex.org/I130416959","display_name":"Central Research Institute of Electric Power Industry","ror":"https://ror.org/041jswc25","country_code":"JP","type":"nonprofit","lineage":["https://openalex.org/I130416959"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Takeo Shiina","raw_affiliation_strings":["Central Research Institute of Electric Power Industory"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Central Research Institute of Electric Power Industory","institution_ids":["https://openalex.org/I130416959"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5011307228","display_name":"Kiyotomi Miyajima","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I130416959","display_name":"Central Research Institute of Electric Power Industry","ror":"https://ror.org/041jswc25","country_code":"JP","type":"nonprofit","lineage":["https://openalex.org/I130416959"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kiyotomi Miyajima","raw_affiliation_strings":["Central Research Institute of Electric Power Industory"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Central Research Institute of Electric Power Industory","institution_ids":["https://openalex.org/I130416959"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I130416959"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"141","issue":"1","first_page":"13","last_page":"20"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.7397000193595886,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.7397000193595886,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.23729999363422394,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.0071000000461936,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/charging-voltage","display_name":"charging voltage","score":0.621999979019165},{"id":"https://openalex.org/keywords/insulated-wire","display_name":"insulated wire","score":0.8259999752044678},{"id":"https://openalex.org/keywords/corona-discharge","display_name":"corona discharge","score":0.8870000243186951},{"id":"https://openalex.org/keywords/ion-flow","display_name":"ion flow","score":0.9419999718666077},{"id":"https://openalex.org/keywords/electric-field","display_name":"electric field","score":0.6299999952316284},{"id":"https://openalex.org/keywords/ion-current-density","display_name":"ion current density","score":0.8700000047683716},{"id":"https://openalex.org/keywords/surface-potential","display_name":"surface potential","score":0.621999979019165},{"id":"https://openalex.org/keywords/electric-shock","display_name":"electric shock","score":0.6200000047683716}],"concepts":[{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6303699016571045},{"id":"https://openalex.org/C34800285","wikidata":"https://www.wikidata.org/wiki/Q5159395","display_name":"Conductor","level":2,"score":0.6293233036994934},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.567365288734436},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5396783947944641},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5321136116981506},{"id":"https://openalex.org/C60799052","wikidata":"https://www.wikidata.org/wiki/Q46221","display_name":"Electric field","level":2,"score":0.5007405281066895},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.48477834463119507},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4510967433452606},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3838284909725189},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3118075728416443},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.21302714943885803},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.1481996476650238},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1541/ieejpes.141.13","doi":"https://doi.org/10.1541/ieejpes.141.13","is_oa":false,"landing_page_url":"https://doi.org/10.1541/ieejpes.141.13","pdf_url":null,"source":{"id":"https://openalex.org/S53799065","display_name":"IEEJ Transactions on Power and Energy","issn_l":"0385-4213","issn":["0385-4213","1348-8147"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800591","host_organization_name":"Institute of Electrical Engineers of Japan","host_organization_lineage":["https://openalex.org/P4320800591"],"host_organization_lineage_names":["Institute of Electrical Engineers of Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEJ Transactions on Power and Energy","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W170254441","https://openalex.org/W2024056549","https://openalex.org/W2035715174","https://openalex.org/W2045099865","https://openalex.org/W2057055390","https://openalex.org/W2064443389","https://openalex.org/W2090652674","https://openalex.org/W2096228893","https://openalex.org/W2138867711","https://openalex.org/W2158665946","https://openalex.org/W2494265162","https://openalex.org/W2511896663","https://openalex.org/W2513122345","https://openalex.org/W2513793926","https://openalex.org/W2605482323","https://openalex.org/W2996593372","https://openalex.org/W4237615154"],"related_works":["https://openalex.org/W2513122345","https://openalex.org/W2917036710","https://openalex.org/W2029494574","https://openalex.org/W3120917646","https://openalex.org/W2254239492","https://openalex.org/W2045099865","https://openalex.org/W2380551906","https://openalex.org/W2138867711","https://openalex.org/W4401537826","https://openalex.org/W1974677771"],"abstract_inverted_index":{"Conductive":[0],"objects":[1],"insulated":[2,52,95,112,143,156,191,237],"from":[3,129],"the":[4,13,22,25,39,58,62,67,71,90,94,107,130,139,142,151,159,175,180,182,186,190,211,217,222,229,232],"ground":[5,176],"under":[6,120,200,245],"DC":[7,48,122,247],"transmission":[8,49,123,248],"lines":[9,203],"are":[10],"electrified":[11,56],"by":[12,18,61,162],"flow":[14,41,64],"of":[15,24,31,38,70,93,141,154,189,210,231,235],"ions":[16],"supplied":[17],"corona":[19],"discharge":[20],"on":[21,138],"surface":[23,60,92,140,188,197],"line":[26],"conductor.":[27],"The":[28,125,145,207],"charge":[29,108,136,152,183,212,233],"voltage":[30,109,137,153,184,213,234],"a":[32,36,85,102,115,121,196,240,246],"human":[33,87],"body":[34,88],"as":[35,167],"result":[37],"ion":[40,63,171],"is":[42,54,73,76,226],"an":[43,79,111,155,236],"important":[44],"factor":[45],"in":[46,158],"designing":[47],"lines.":[50],"An":[51],"wire":[53,72,113,157,192,238],"also":[55],"at":[57,174,185,205],"outer":[59,91,187],"even":[65],"when":[66,84],"core":[68,117,242],"conductor":[69,118,243],"grounded.":[74],"There":[75],"concern":[77],"whether":[78],"electric":[80,133,168],"shock":[81],"can":[82],"occur":[83],"grounded":[86,116,241],"touches":[89],"wire.":[96,144],"In":[97],"this":[98],"study,":[99],"we":[100],"derived":[101,128,224],"new":[103],"equation":[104,126,146,225],"for":[105,110],"predicting":[106],"with":[114,216,239],"placed":[119,244],"line.":[124,249],"was":[127,193],"relationship":[131],"between":[132],"field":[134,169],"and":[135,170],"allows":[147],"us":[148],"to":[149,228],"assess":[150],"steady":[160],"state":[161],"using":[163,195],"input":[164],"parameters":[165],"such":[166],"current":[172],"density":[173],"level.":[177],"To":[178],"validate":[179],"equation,":[181],"measured":[194,218],"potential":[198],"electrometer":[199],"bipolar-DC":[201],"test":[202],"energized":[204],"\u00b1200kV.":[206],"predicted":[208],"results":[209],"agreed":[214],"well":[215],"results,":[219],"indicating":[220],"that":[221],"newly":[223],"applicable":[227],"prediction":[230]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W3119731952","counts_by_year":[],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2021-01-18T00:00:00"}
